The nVent A12R84NK is a 12x8x4 inch Type 3R screw-cover drip-shield enclosure constructed from 16-gauge galvanized steel, finished with an ANSI 61 gray polyester powder paint for corrosion resistance and durability. Designed for outdoor applications, it provides protection against rain, sleet, snow, and external ice formation, meeting UL 50 and UL 50E standards for Type 3R enclosures. The screw-cover design features a 3/4-inch overhang that acts as a drip shield, minimizing water ingress through the cover interface. This enclosure has seam-free sides, front, and back to reduce potential entry points for moisture and contaminants. The back panel includes embossed mounting holes for direct surface mounting without additional hardware. It does not include gasketing or pre-punched knockouts, allowing for custom sealing of entry points based on specific installation requirements. Manufactured by nVent, this enclosure is suitable for use as a wiring, junction, or pull box in outdoor settings where Type 3R protection is required. It is UL 50, UL 50E Listed; Type 3R and cUL Listed per CSA C22.2 No 94; Type 3R standards, ensuring compliance with North American electrical safety regulations. Dimensions are 12 inches in height, 8 inches in width, and 4 inches in depth.
  • Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
  • Slip-on removable cover fastened with plated steel screws along bottom edge
  • Handles on larger sizes (see table)
  • Embossed mounting holes on back of enclosure
  • Knockouts in bottom of 16 and 14 gauge enclosures
  • Provision for padlocking
  • No gasketing
  • Enclosures are finished with paint over plated surfaces
  • Top and bottom thickness gauge is the same as the body thickness gauge unless otherwise noted in table

Specifications

Application
Power Distribution
Body Style
A
Body Thickness
16 ga
Color
Gray
Color Code
ANSI 61
Depth
13 IN
Depth
4 in
Depth, Maximum
4
Depth, Minimum
4
Door Thickness
14 ga
Door Thickness
16 ga
Finish
Galvanized
Height
44 IN
Height
12 IN
IP Rating
IP32
Knockouts
False
Knockouts Included
No
Material
Steel
Material
Mild Steel;Steel
Modification Services
Yes
Mounting
27;57 mm;mm
Mounting
1.06;2.25 in;in
Mounting
Wall Mounting Brackets Available
NEMA Rating
3r
NEMA Rating
NEMA 6
Protection Rating
NEMA Type 3R
Size
12.00x8.00x4.00 in
Type
Screw-Cover Junction Boxes Type 3R
Type
Pull and Junction Boxes
Type Number
Type 3R
Weight
7 lb
Width
203 mm
Width
8 in
Package Dimensions (L x W x H)
12 IN x 8.3 IN x 4.2 IN
Package Dimensions (L x W x H)
30.48 cm x 21.082 cm x 10.668 cm
Package Weight (Imperial)
7.000 L
Package Weight (Metric)
3.175 kg
Screw-Cover Drip-Shield Type 3R With Knockouts, 12x8x4, Gray, Steel

A12R84

Screw-Cover Drip-Shield Type 3R With Knockouts, 12x8x4, Gray, Steel
The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

AB314

The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

How to Install the A12R84NK Controller

This guide provides step-by-step instructions for mounting and wiring the A12R84NK Controller securely.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A12R84NK controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the ends of the wires. Connect the wires to the appropriate terminals on the controller, ensuring a secure fit. Refer to the wiring diagram for correct terminal assignments.

  3. Verify connections

    Use a multimeter to check the continuity of the connections. Ensure that all connections are secure and that there are no short circuits before powering on the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.