nVent A12106NFSS - Clamp Cover Junction Box Type 4X, 12x10x6, SS304
nVent

A12106NFSS

UPC: 783510569501


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent Clamp Cover Junction Box Type 4X (SKU: A12106NFSS)** is a premium stainless steel enclosure designed for demanding industrial applications where durability, corrosion resistance, and reliable sealing are critical. Engineered by nVent, a global leader in thermal management and electrical solutions, this junction box combines robust construction with innovative design features to deliver unmatched performance in harsh environments. Whether deployed in chemical processing plants, wastewater treatment facilities, offshore platforms, or outdoor industrial sites, this enclosure ensures long-term protection for electrical components against moisture, dust, and corrosive agents. **Key Features and Benefits:** - **Superior Corrosion Resistance:** Constructed from **304 stainless steel**, this junction box resists rust, oxidation, and chemical degradation, making it ideal for coastal, marine, or chemical exposure applications. Unlike painted or coated enclosures, stainless steel provides inherent durability without the risk of coating failure over time. - **Type 4X Rated for Extreme Conditions:** Certified to **NEMA Type 4X** standards, the enclosure withstands water ingress, hose-directed spray, and prolonged exposure to outdoor elements. This rating is essential for industries such as oil & gas, mining, and food processing, where equipment must operate reliably in wet or contaminated environments. - **Foam-In-Place Gasket with Stainless Steel Clamps:** The seamless, pre-installed gasket ensures a consistent seal, eliminating gaps that could compromise protection. The **stainless steel screw-down clamps** provide uniform compression, maintaining integrity even under thermal cycling or mechanical stress. Unlike snap-fit designs, this system allows for easy access while ensuring a tight seal when closed. - **Modular and Adaptable Design:** With internal dimensions of **12x10x6 inches**, the enclosure accommodates a wide range of electrical components, including terminal blocks, relays, and PLCs. The spacious interior simplifies wiring and future modifications, reducing downtime during upgrades or maintenance. - **Easy Installation and Maintenance:** The clamp cover design enables quick removal and reinstallation without tools in many cases, streamlining inspections, repairs, and reconfigurations. This feature is particularly valuable in facilities where operational continuity is prioritized, such as data centers, manufacturing plants, or utility substations. **Industry Applications:** The nVent Clamp Cover Junction Box is a versatile solution for industries where electrical enclosures face extreme conditions. Common applications include: - **Oil & Gas:** Protection of control panels, sensors, and junction points in refineries, pipelines, and offshore platforms where exposure to saltwater, hydrocarbons, and corrosive gases is constant. - **Water/Wastewater Treatment:** Reliable housing for motor controls, variable frequency drives (VFDs), and instrumentation in facilities exposed to high humidity, chemicals, and frequent washdowns. - **Food & Beverage Processing:** Compliance with hygiene standards while resisting washdowns with caustic cleaning agents and high-pressure water jets. - **Marine & Coastal Infrastructure:** Durable protection for lighting controls, navigation systems, and communication equipment in ports, docks, and coastal facilities. - **Chemical Processing:** Safeguarding electrical components in plants handling acids, alkalis, or solvents where standard enclosures would degrade rapidly. **Why Choose nVent?** nVent is a trusted name in industrial electrical solutions, known for innovation, reliability, and adherence to global standards. The **A12106NFSS junction box** reflects the company’s commitment to engineering products that meet the rigorous demands of modern industrial environments. With a focus on **sealing integrity, material durability, and ease of maintenance**, nVent enclosures reduce the risk of costly downtime and equipment failure. Professionals in electrical design, maintenance, and procurement consistently choose nVent for its **proven performance, extensive certifications, and compatibility with industry-leading accessories** (e.g., conduit fittings, cable glands). **Installation and Compliance Considerations:** When specifying the A12106NFSS, professionals should ensure compatibility with local electrical codes (e.g., NEC, IEC) and environmental ratings. The **Type 4X rating** covers indoor and outdoor use, but additional considerations may include: - **Mounting:** The enclosure can be surface-mounted or mounted to a back panel using the provided holes. For outdoor applications, ensure proper orientation to prevent water pooling on the cover. - **Ventilation:** While the enclosure is sealed, some applications may require ventilation to prevent condensation buildup. nVent offers compatible vent plugs or desiccant solutions for such scenarios. - **Accessories:** Pair the junction box with **stainless steel conduit fittings, cable glands, or gland plates** to maintain the Type 4X rating and simplify installation. **Long-Term Value:** Investing in the nVent Clamp Cover Junction Box delivers **cost savings** through reduced maintenance, fewer replacements, and minimized risk of electrical failures. Its **304 stainless steel construction** ensures a lifespan measured in decades, even in aggressive environments, while the **clamp cover design** reduces labor costs associated with frequent access. For facilities where reliability is non-negotiable, this enclosure is a strategic choice that aligns with operational efficiency and safety goals.
  • Seams continuously welded and ground smooth
  • Seamless foam-in-place gasket
  • Stainless steel screws and clamps
  • Weldnuts provided for mounting optional panels and terminal block kits in size 6.00 x 4.00 in. (152 x 102 mm) and larger
  • Bonding provision on door and body
  • Bonding provision on door and body

Specifications

Application
Controls and Drives;Corrosive Environments
Body Thickness
14 ga
Body Thickness
16 ga
Color
Unpainted
Conductive Steel Panel
A12P10G
Depth
13 IN
Depth
6 in
Depth, Maximum
6
Depth, Minimum
6
Door Thickness
16 ga
Door Thickness
14 ga
Finish
Brushed #4
Height
44 IN
Height
12 IN
IP Rating
IP66
Material
Stainless Steel;Stainless Steel 304
Material
Stainless Steel
Modification Services
Yes
Mounting
12.75 x 8.00 in
Mounting
Wall Mounting Brackets Available
NEMA Rating
4X
NEMA Rating
NEMA 6
Overall Dimensions
13.50 x 11.38 in
Overall Dimensions
114 x 88 mm
Panel Size
10.75 x 8.88 in
Panel Size
72.00 x 72.00 in
Protection Rating
NEMA Type 12
Size
12.00x10.00x6.00 in
Steel Panel
A12P10
Type
Stainless Steel Terminal and Junction Boxes
Type
Stainless Steel Industrial Terminal and Junction Boxes
Type Number
Type 3R
Weight
11.4 lb
Width
10 IN
Width
254 mm
Package Dimensions (L x W x H)
13.5 IN x 11.25 IN x 6.5 IN
Package Dimensions (L x W x H)
34.29 cm x 28.575 cm x 16.51 cm
Package Weight (Imperial)
11.850 L
Package Weight (Metric)
5.375 kg
Continuous Hinge with Clamps Junction Box Type 4X, 12x10x6, Brushed, Stainless 304

A12106CHNFSS

Continuous Hinge with Clamps Junction Box Type 4X, 12x10x6, Brushed, Stainless 304
RELIAMOD PULL BOX 800A 3-PHASE

RMM3P8R

RELIAMOD PULL BOX 800A 3-PHASE

How to Install the Grounding Kit for E9PBY25M

This guide provides step-by-step instructions for installing the grounding kit for the E9PBY25M, ensuring proper electrical continuity and safety.

Estimated time: 15m

Tools needed:

Screwdriver, Torque wrench

Supplies needed:

10-32x5/8 screws, Keps nuts, 10-32 hex nuts, Lockwashers, Ground wire, Grounding label

  1. Insert the mounting screw

    Insert the 10-32x5/8 screw through the designated hole in the panel.

  2. Secure the screw

    Tighten the screw using a keps nut, ensuring that the nut penetrates into the paint for proper electrical continuity.

  3. Attach the ground wire

    Connect the ground wire and secure it using a 10-32 hex nut.

  4. Install the lockwasher

    Place a lockwasher under one of the screws securing the panel to ensure grounding between the panel and the enclosure. Do not exceed a torque of 30 in-lbs.

  5. Apply the grounding label

    Attach the included grounding label adjacent to the bolt as indicated in the installation instructions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.