nVent A10R106 - Screw-Cover Drip-Shield Type 3R With Knockouts, 10x10x6, Gray, Steel
nVent

A10R106

UPC: 783510381202


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent Screw-Cover Drip-Shield Type 3R Enclosure (SKU: A10R106)** is a robust, weatherproof solution designed for outdoor electrical and control applications where protection from rain, sleet, snow, and dripping water is critical. Engineered by nVent, a global leader in electrical and thermal management solutions, this enclosure combines durability, functionality, and compliance with industry standards to safeguard sensitive equipment in harsh environments. With a compact 10x10x6 inch form factor and a gray steel construction, the Type 3R enclosure is ideal for junction boxes, control panels, and wiring applications in commercial, industrial, and utility settings. This enclosure features a **screw-cover design** with knockouts for easy cable entry and secure mounting, ensuring a tight seal against environmental ingress. The **NEMA Type 3R rating** guarantees protection against falling rain, sleet, and external ice formation, making it suitable for outdoor installations in exposed locations such as building exteriors, utility poles, and industrial sites. The steel construction provides exceptional strength and corrosion resistance, while the knockouts allow for flexible conduit routing to accommodate various wiring configurations. **Key Applications and Industries:** The nVent Screw-Cover Drip-Shield Type 3R Enclosure is widely used in industries where outdoor electrical and control systems require reliable protection. Common applications include: - **Commercial buildings** for outdoor lighting controls, HVAC systems, and security panels. - **Industrial facilities** for motor control centers, sensor enclosures, and process automation equipment. - **Utility and telecommunications** for junction boxes, power distribution units, and fiber optic splicing closures. - **Agricultural and irrigation systems** for weather-resistant control panels and pump stations. - **Transportation infrastructure** for traffic signal controllers, toll booth systems, and roadside equipment. **Installation and Compliance Considerations:** Professionals select the Type 3R enclosure for its **ease of installation** and **versatility**. The screw-cover design allows for quick access to internal components for maintenance or upgrades, while the knockouts simplify conduit entry without compromising protection. The enclosure meets **NEMA Type 3R** and **IP54** standards, ensuring resistance to dust ingress and water splashes. When installing, ensure proper gasket sealing and secure mounting to maintain weatherproof integrity over time. **Why Choose nVent?** As a trusted manufacturer in the electrical and thermal management space, nVent delivers products that prioritize **safety, reliability, and innovation**. The Screw-Cover Drip-Shield Type 3R Enclosure reflects their commitment to providing solutions that meet the demands of modern industrial and commercial environments. With a focus on **durability, compliance, and ease of use**, this enclosure is a cost-effective choice for professionals who need to protect critical systems from the elements. For outdoor electrical and control applications requiring a **weatherproof, durable, and code-compliant enclosure**, the nVent Screw-Cover Drip-Shield Type 3R (A10R106) is a proven solution that delivers performance and peace of mind.
  • Drip shield top and seam-free sides, front, and back protect from rain, snow, or sleet
  • Slip-on removable cover fastened with plated steel screws along bottom edge
  • Handles on larger sizes (see table)
  • Embossed mounting holes on back of enclosure
  • Knockouts in bottom of 16 and 14 gauge enclosures
  • Provision for padlocking
  • No gasketing
  • Enclosures are finished with paint over plated surfaces
  • Top and bottom thickness gauge is the same as the body thickness gauge unless otherwise noted in table

Specifications

Application
Power Distribution
Body Style
A
Body Thickness
16 ga
Color
Gray
Color Code
ANSI 61
Depth
6 in
Depth
13 IN
Depth, Maximum
6
Depth, Minimum
6
Door Thickness
14 ga
Door Thickness
16 ga
Finish
Galvanized
Height
44 IN
Height
10 IN
IP Rating
IP32
IP Rating
IP54
Knockout Pattern
C-D-E-F-G
Knockouts
True
Knockouts Included
Yes
Material
Mild Steel;Steel
Material
Steel
Modification Services
Yes
Mounting
27;57 mm;mm
Mounting
Wall Mounting Brackets Available
Mounting
1.06;2.25 in;in
Mounting Type
Wall-mount
NEMA Rating
NEMA 6
NEMA Rating
3r
NEMA Rating
Type 3R
Protection Rating
NEMA Type 3R
Size
10.00x10.00x6.00 in
Size
10x10x6
Size
10x10x6 inch
Type
Pull and Junction Boxes
Type
Screw-Cover Junction Boxes Type 3R
Type Number
Type 3R
Weight
9 lb
Width
10 IN
Width
254 mm
Package Dimensions (L x W x H)
10.3 IN x 10.3 IN x 6 IN
Package Dimensions (L x W x H)
26.162 cm x 26.162 cm x 15.24 cm
Package Weight (Imperial)
9.000 L
Package Weight (Metric)
4.082 kg
Screw-Cover Drip-Shield Type 3R no Knockouts, 10x10x6, Gray, Steel

A10R106NK

Screw-Cover Drip-Shield Type 3R no Knockouts, 10x10x6, Gray, Steel
The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

AB314

The NEMA 4/4X/12 features a standard padlock-able feature with a single or (2) single point latches depending on the enclosure size. They are galvanealed steel coated. (Padlocks not included)

How to Install the A36R3612NK Enclosure

This guide provides step-by-step instructions for installing the A36R3612NK enclosure securely and safely.

Estimated time: 30m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Padlock staple

  1. Prepare the installation site

    Select a suitable location for the A36R3612NK enclosure, ensuring it is level and accessible for wiring.

  2. Mount the enclosure

    Secure the enclosure to the wall or mounting surface using appropriate mounting screws. Ensure it is firmly attached and level.

  3. Install the padlock staple

    Push the padlock staple through the slot in the bottom of the enclosure from the inside until it snaps in place for added security.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.