TE Connectivity T2111342201-000 Insert for Contacts, Socket, Crimp Terminal, 40 A, Power & Signal, HDC HMN
Documents & Media
Contact for Pricing
Minimum Qty: 192
Multiplier: 192
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- TE Connectivity HDC HMN Socket Insert
- 40A Current Rating
- Designed for Crimp Terminals
- Suitable for Power & Signal Applications
- SKU: T2111342201-000
Specifications
Application | Power & Signal |
Length | 45.7 mm |
Material | Polycarbonate |
Material | PC |
Standard | UL94V-0 |
Type | Insert for Contacts |
Type | HDC HMN Modular System, Rail Compliant |

T2115032101-000
Insert for Contacts, Pin, 3 Pole Configuration, Crimp Terminal, 1.2 A, Power & Signal, HDC HMN
T2115032201-000
Insert for Contacts, Socket, 3 Pole Configuration, Crimp Terminal, 1.2 A, Power & Signal, HDC HMN
T2120062201-001
Insert for Contacts, Socket, 6 Pole Configuration, Crimp, 6 – 8 AWG, 10 – 16 mm² Wire, 60 A, Power & Signal
T2120062101-001
Insert for Contacts, Pin, 6 Pole Configuration, Crimp, 6 – 8 AWG, 10 – 16 mm² Wire, 60 A, Power & SignalFrequently Asked Questions
What is the wire range for power and signal terminals?
Power terminals accept wire sizes from 1.0 mm2 to 6.0 mm2, while signal terminals accept 0.14 mm2 to 2.5 mm2.
What are the rated current and voltage for power and signal connections?
Power connections are rated for 40A and 830V, while signal connections are rated for 10A and 830V.
What is the operating temperature range for this connector?
The connector operates within a temperature range of -40°C to +125°C.
What is the IP rating for this HMN-3/4 connector?
The connector has an IP20 protection rating.
What is the dielectric strength (withstand voltage) for the power and signal contacts?
The power and signal contacts have a withstand voltage rating of 8KV.
What is the insulation resistance of the connector?
The insulation resistance is not less than 400MΩ when tested at 1000V DC for 60s.
What is the maximum contact resistance for signal and power terminals?
The initial contact resistance is a maximum of 5 mΩ for signal and 3 mΩ for power.
How many mating cycles can the connector withstand?
The connector is designed for 500 mechanical operation cycles without functional damage.
What are the requirements for terminal retention force?
DD terminals require a minimum axial retention force of 50N, and MM terminals require a minimum of 70N.
Frequently Asked Questions about TE Connectivity
What technical support does TE Connectivity offer?
TE Connectivity offers comprehensive technical support through multiple channels, including a dedicated technical hotline at 1-800-777-3300. The company provides advanced technical support with 3 dedicated support centers, a global technical hotline network, and delivers over 8,000 hours of technical training annually to ensure certified expertise across 25+ languages.
What environmental ratings do TE Connectivity products have?
TE Connectivity products feature robust environmental ratings across multiple standards, including NEMA Type 1, 2, 3, 3R, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. Our enclosures are designed to withstand challenging industrial environments, with operating temperatures ranging from -40°C to 130°C, and include enhanced UV inhibitors for outdoor applications.
What certifications and standards do TE Connectivity products comply with?
TE Connectivity products meet rigorous international certifications and standards across industrial automation applications, including UL (United States), CSA (Canada), CE (European Community), and international safety standards. Our product lines are designed to comply with critical industrial certifications such as NEMA (Types 4, 4X, 6, 6P), IP ratings (IP65, IP66, IP67, IP69K), and industrial communication protocols including PROFINET, EtherNet/IP, and DeviceNet. We ensure comprehensive compliance through active participation in key industrial standards committees and maintaining ISO 9001 quality system certification.
What industries and applications are TE Connectivity products used for?
TE Connectivity products are engineered for critical industrial applications across multiple sectors, including industrial device manufacturing, automotive, robotics, food and beverage, material handling, alternative energy, and commercial vehicle industries. Their solutions span connectivity, power distribution, network communications, and sensor technologies that support complex industrial automation requirements, with a focus on robust connectivity solutions for challenging manufacturing environments.
What are the main product lines offered by TE Connectivity?
TE Connectivity offers a comprehensive range of industrial connectivity solutions including Cable Ties, Cable Cleats, Power Connectors, Grounding Connectors, Terminals, Safety Solutions, Identification Products, and Wiring Duct. Their product lines are designed for robust industrial applications, featuring various connection technologies like wave soldering, spring-cage connections, and mis-insertion protection across multiple electrical and connectivity categories.
What accessories are available for TE Connectivity products?
TE Connectivity offers a comprehensive range of communication and bus accessories for industrial automation systems, including communication terminal boards (CTB810, CTB811), bus extenders (horizontal and vertical models like cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories are designed to enhance connectivity, power distribution, and communication capabilities for HN800 and CW800 controller systems, with options for left/right side mounting, power connections, and network termination.
How are TE Connectivity products typically installed?
TE Connectivity products are typically installed through professional commissioning services that include site audits, precise wiring verification, and both remote and on-site installation support. Our expert service engineers conduct comprehensive installation processes involving system verification, programming, communication testing, and personnel training to ensure optimal performance and reliability of the equipment.