Authorized TE Connectivity Distributor
TE Connectivity T2111028201-007 - Socket, Insert for Contacts, 2 Pole Configuration, 100 A, Crimp, Power & Signal, HDC HMN

TE Connectivity T2111028201-007 Socket, Insert for Contacts, 2 Pole Configuration, 100 A, Crimp, Power & Signal, HDC HMN


Documents & Media
Full Engineering DrawingSpecification Sheet

Contact for Pricing

Minimum Qty: 96

Multiplier: 96

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This TE Connectivity HDC HMN socket insert (SKU: T2111028201-007) is designed for robust power and signal applications. It features a 2-pole configuration and supports a 100A current rating, utilizing crimp-style contacts for secure connections. The insert is constructed with PC (grey) and PBT (natural) insulation materials, ensuring reliable performance. It is rated for a maximum of 32V and 2.2A per contact, with a high insulation resistance of >=100MΩ and a rated impulse voltage of 0.8 KV. This component is part of the HDC HMN series, known for its durable construction and suitability for applications requiring dependable power and signal transmission. Contacts are ordered separately, with options for silver-plated or gold-plated crimp contacts available for various wire gauges from 0.14-4.0 mm² (AWG 26-12). The insert is designed for use with specific hoods and housings, facilitating modular assembly in control cabinets and industrial machinery. Its flammability rating is UL94V-0, and it operates within pollution degree 3.
  • 2 Pole Configuration for Power & Signal
  • 100A Current Rating
  • Crimp Contact Termination
  • Durable PC and PBT Insulation Materials

Specifications

Application
Power & Signal
Connection Type
Crimp
Current Rating
100 A
Length
54.5 mm
Material
Polycarbonate
Poles
2
Series
HDC HMN
Standard
UL94V-0
Type
HDC HMN Modular System, Rail Compliant
Insert for Contacts, Pin, 3 Pole Configuration, Crimp Terminal, 1.2 A, Power & Signal, HDC HMN

T2115032101-000

Insert for Contacts, Pin, 3 Pole Configuration, Crimp Terminal, 1.2 A, Power & Signal, HDC HMN
Concrete Insert, insert channel 12 guage steel, 13/16 inch depth. 10 foot.

B302 10

Concrete Insert, insert channel 12 guage steel, 13/16 inch depth. 10 foot.
Die Insert for CA9 Applicator

CD9-1B

Die Insert for CA9 Applicator
Socket, Insert for Contacts, 2 Pole Configuration, 100 A, Crimp, Power & Signal, HDC HMN

T2111028201-000

Socket, Insert for Contacts, 2 Pole Configuration, 100 A, Crimp, Power & Signal, HDC HMN
Pin, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Signal, HDC HMN

T2111252101-007

Pin, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Signal, HDC HMN
Pin, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Power & Signal, HDC HMN

T2111252101-000

Pin, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Power & Signal, HDC HMN
Socket, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Power & Signal, HDC HMN

T2111252201-000

Socket, Insert for Contacts, 25 Pole Configuration, 28 – 20 AWG, 5 A, Crimp, Power & Signal, HDC HMN
Pin, Insert for Contacts, 20 Pole Configuration, 26 – 12 AWG, .14 – 4 mm² Wire, 16 A, Crimp, Power & Signal, HDC HMN

T2111202101-000

Pin, Insert for Contacts, 20 Pole Configuration, 26 – 12 AWG, .14 – 4 mm² Wire, 16 A, Crimp, Power & Signal, HDC HMN

Frequently Asked Questions

What is the maximum initial contact resistance?

The maximum initial contact resistance is 0.5mΩ when tested with a 1A test current.

What is the insulation resistance requirement?

The insulation resistance must be not less than 400MΩ when tested with 1000V DC for 60s.

What is the contact retention force for HMN-D2 series inserts?

The minimum contact retention force for each pin or socket is 120N.

What is the operating temperature range for this product?

The product can withstand temperatures from -40℃ to +125℃ during rapid temperature changes.

How many durability cycles can the HMN-D2 series insert withstand?

The insert can withstand 500 operation cycles without load and without damage likely to impair normal use.

What is the dielectric voltage withstand test requirement?

The product must withstand impulse test voltage without flashover or breakdown.

What is the grounding contact resistance limit?

The resistance between accessible metal parts and the earthing contact must be less than or equal to 0.1Ω.

What are the requirements for protection against electric shock?

No live parts should be accessible by a test finger or 50mm sphere pressed with 20N.

Frequently Asked Questions about TE Connectivity

What technical support does TE Connectivity offer?

TE Connectivity offers comprehensive technical support through multiple channels, including a dedicated technical hotline at 1-800-777-3300. The company provides advanced technical support with 3 dedicated support centers, a global technical hotline network, and delivers over 8,000 hours of technical training annually to ensure certified expertise across 25+ languages.

What environmental ratings do TE Connectivity products have?

TE Connectivity products feature robust environmental ratings across multiple standards, including NEMA Type 1, 2, 3, 3R, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. Our enclosures are designed to withstand challenging industrial environments, with operating temperatures ranging from -40°C to 130°C, and include enhanced UV inhibitors for outdoor applications.

What certifications and standards do TE Connectivity products comply with?

TE Connectivity products meet rigorous international certifications and standards across industrial automation applications, including UL (United States), CSA (Canada), CE (European Community), and international safety standards. Our product lines are designed to comply with critical industrial certifications such as NEMA (Types 4, 4X, 6, 6P), IP ratings (IP65, IP66, IP67, IP69K), and industrial communication protocols including PROFINET, EtherNet/IP, and DeviceNet. We ensure comprehensive compliance through active participation in key industrial standards committees and maintaining ISO 9001 quality system certification.

What industries and applications are TE Connectivity products used for?

TE Connectivity products are engineered for critical industrial applications across multiple sectors, including industrial device manufacturing, automotive, robotics, food and beverage, material handling, alternative energy, and commercial vehicle industries. Their solutions span connectivity, power distribution, network communications, and sensor technologies that support complex industrial automation requirements, with a focus on robust connectivity solutions for challenging manufacturing environments.

What are the main product lines offered by TE Connectivity?

TE Connectivity offers a comprehensive range of industrial connectivity solutions including Cable Ties, Cable Cleats, Power Connectors, Grounding Connectors, Terminals, Safety Solutions, Identification Products, and Wiring Duct. Their product lines are designed for robust industrial applications, featuring various connection technologies like wave soldering, spring-cage connections, and mis-insertion protection across multiple electrical and connectivity categories.

What accessories are available for TE Connectivity products?

TE Connectivity offers a comprehensive range of communication and bus accessories for industrial automation systems, including communication terminal boards (CTB810, CTB811), bus extenders (horizontal and vertical models like cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories are designed to enhance connectivity, power distribution, and communication capabilities for HN800 and CW800 controller systems, with options for left/right side mounting, power connections, and network termination.

How are TE Connectivity products typically installed?

TE Connectivity products are typically installed through professional commissioning services that include site audits, precise wiring verification, and both remote and on-site installation support. Our expert service engineers conduct comprehensive installation processes involving system verification, programming, communication testing, and personnel training to ensure optimal performance and reliability of the equipment.