- 1.2 VA coil power rating for precise AC operation
- 11 Ω coil resistance for stable performance
- Monostable configuration ensures default state on power removal
- Compatible with standard relay sockets and panels
- Manufactured in the US for high-quality standards
Specifications
Feature | Type of electric connection |
Feature | Width |
Feature | Height |
Feature | Depth |
Series | KHA |

1-1393143-3
Relay Accessories, Sockets & Clips, Printed Circuit Board, Phenolic, Printed Circuit Board, 6, Socket, Potter & Brumfield R10
1-1393143-6
Relay Accessories, Sockets & Clips, Solder, Polyester, Printed Circuit Board, 2, Socket, Potter & Brumfield R10
SCP102D24X-C02
IP67 SCP-X Extreme Environment Series Power Supply. Double Stacked, Output Power 2 x 100W, Output Voltage 24 Vdc, Output Current 7.6 A total, 3.8 A per pairFrequently Asked Questions
What are the available coil voltage ranges for this relay?
The relay supports coil voltages from 5 to 240VDC and 6 to 240VAC.
What contact arrangements are available for the KHA Series relay?
The relay is available with 2 form C (2CO) or 4 form C (4CO) contact arrangements.
What contact materials are offered for the KHA Series relay?
Available contact materials include Ag, AgCdO, Au-AgNi, Au overlay Ag, and Au diffused Ag.
What is the operating temperature range for the KHA Series relay?
The ambient temperature range for this relay is -45ºC to 70ºC.
What are the rated voltage and current for the contacts?
The rated voltage for the contacts is 240VAC, and the rated current is 1-5A.
What is the maximum continuous current the relay can handle?
The relay should only carry a maximum of 15A continuously across all poles combined.
What is the coil insulation system class according to UL?
The coil insulation system is Class B according to UL standards.
What is the mechanical endurance of the KHA Series relay?
The mechanical endurance of the relay is rated for 10 million operations.
What are the insulation specifications between contacts and coil?
The initial dielectric strength between the contact and coil is 1500Vrms.
What types of sockets are available for KHA relays?
Available sockets include DIN, panel/track mount, solder/grounding, and PCB/grounding types.
Frequently Asked Questions about TE Connectivity
What technical support does TE Connectivity offer?
TE Connectivity offers comprehensive technical support through multiple channels, including a dedicated technical hotline at 1-800-777-3300. The company provides advanced technical support with 3 dedicated support centers, a global technical hotline network, and delivers over 8,000 hours of technical training annually to ensure certified expertise across 25+ languages.
What environmental ratings do TE Connectivity products have?
TE Connectivity products feature robust environmental ratings across multiple standards, including NEMA Type 1, 2, 3, 3R, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. Our enclosures are designed to withstand challenging industrial environments, with operating temperatures ranging from -40°C to 130°C, and include enhanced UV inhibitors for outdoor applications.
What certifications and standards do TE Connectivity products comply with?
TE Connectivity products meet rigorous international certifications and standards across industrial automation applications, including UL (United States), CSA (Canada), CE (European Community), and international safety standards. Our product lines are designed to comply with critical industrial certifications such as NEMA (Types 4, 4X, 6, 6P), IP ratings (IP65, IP66, IP67, IP69K), and industrial communication protocols including PROFINET, EtherNet/IP, and DeviceNet. We ensure comprehensive compliance through active participation in key industrial standards committees and maintaining ISO 9001 quality system certification.
What industries and applications are TE Connectivity products used for?
TE Connectivity products are engineered for critical industrial applications across multiple sectors, including industrial device manufacturing, automotive, robotics, food and beverage, material handling, alternative energy, and commercial vehicle industries. Their solutions span connectivity, power distribution, network communications, and sensor technologies that support complex industrial automation requirements, with a focus on robust connectivity solutions for challenging manufacturing environments.
What are the main product lines offered by TE Connectivity?
TE Connectivity offers a comprehensive range of industrial connectivity solutions including Cable Ties, Cable Cleats, Power Connectors, Grounding Connectors, Terminals, Safety Solutions, Identification Products, and Wiring Duct. Their product lines are designed for robust industrial applications, featuring various connection technologies like wave soldering, spring-cage connections, and mis-insertion protection across multiple electrical and connectivity categories.
What accessories are available for TE Connectivity products?
TE Connectivity offers a comprehensive range of communication and bus accessories for industrial automation systems, including communication terminal boards (CTB810, CTB811), bus extenders (horizontal and vertical models like cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories are designed to enhance connectivity, power distribution, and communication capabilities for HN800 and CW800 controller systems, with options for left/right side mounting, power connections, and network termination.
How are TE Connectivity products typically installed?
TE Connectivity products are typically installed through professional commissioning services that include site audits, precise wiring verification, and both remote and on-site installation support. Our expert service engineers conduct comprehensive installation processes involving system verification, programming, communication testing, and personnel training to ensure optimal performance and reliability of the equipment.