TE Connectivity 1SNA519104R0200 PC-RG6-2 2 POLE LATERAL JUMPER BAR
Alternate Item Number: 1SNA519104R0200
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 2-pole lateral jumper bar for RGW terminal blocks
- Compatible with 11 mm spacing (RGW6, RGW6-R1, RGW6-ST-1, RGW6-T)
- Rated for 41 A and 1000 V
- Durable Polyamide insulation material
- UL94 V0 flammability rating
Specifications
Ambient Air Temperature | Operation -40 ... +100 °C |
Color | Orange |
Declaration of Conformity - CE | 1SND225158C1001 |
ETIM 4 | EC000489 - Cross-connector for terminal block |
ETIM 5 | EC000489 - Cross-connector for terminal block |
ETIM 6 | EC000489 - Cross-connector for terminal block |
Flammability According to UL94 | V0 |
Function | Jumper Bars |
Insulation Material | Polyamide |
Package Level 1 Depth / Length | 55 mm |
Package Level 1 EAN | 3472600000000 |
Package Level 1 Gross Weight | 0.1 kg |
Package Level 1 Height | 31 mm |
Package Level 1 Units | 25 piece |
Package Level 1 Width | 65 mm |
Package Level 2 Depth / Length | 350 mm |
Package Level 2 Height | 230 mm |
Package Level 2 Units | 3500 piece |
Package Level 2 Width | 230 mm |
Package Level 3 Units | 112000 piece |
Poles | 2 |
Power Loss | 1.3 W |
Product Net Depth / Length | 26.3 mm |
Product Net Height | 16.6 mm |
Product Net Length | 26.7 mm |
Product Net Width | 3.1 mm |
Product Packing Type | Box |
Rated Current (In) | Main Circuit 41 A |
Rated Voltage (Ur) | 1000 V |
RoHS Information | 1SND230547F0201 |
RoHS Status | Following EU Directive 2011/65/EU |
Series | PC-RG6 |
Spacing | 11 mm |
Suitable For | RGW6 |
UL/CSA | Connecting Capacity UL/CSA: Stranded 10 AWG |

1SNA115491R0000
- MA2.5/5.D2 with partition, particulary adapted when many test sockets are used: no circuit separators needed, - Use of jumper bars requires the user to cut out the partition.
1SNA115497R0600
- M6/8.D2 with partition, particulary adapted when many test sockets are used: no circuit separators needed, - Use of jumper bars requires the user to cut out the partition.
1SNA125126R0300
- M4/6.D2 with partition, particulary adapted when many test sockets are used: no circuit separators needed, - Use of jumper bars requires the user to cut out the partition.
1SNA125124R0100
- Closed terminal block: no end section needed, optimized rigidity, - Flexibility: snap onto symmetrical and asymmetrical rails, - Use of Jumper bars requires the user to cut out the partition.
1SNA115260R0300
- Particulary adapted when many test sockets are used: no circuit separators needed, - Use of jumper bars requires the user to cut out the partition, - Flexibility: snap onto symmetrical and asymmetrical rails.
1SNA125129R1600
- Flexibility: snap onto symmetrical and asymmetrical rails, - Many colors are available in addition to our generic grey to help you quickly identify any specific functions, - Use of Jumper bars requires the user to cut out the partition.Frequently Asked Questions
What is the rated voltage for RGW2.5 terminal blocks?
The rated voltage for RGW2.5 terminal blocks is 800 V (IEC), 600 V (UL), and 600 V (CSA).
What is the rated current for RGW6 terminal blocks?
The rated current for RGW6 terminal blocks is 41 A (IEC), 30 A (UL), and 30 A (CSA).
What is the rated voltage for RGW6 terminal blocks?
The rated voltage for RGW6 terminal blocks is 800 V (IEC), 600 V (UL), and 600 V (CSA).
What is the rated current for RGW25 terminal blocks?
The rated current for RGW25 terminal blocks is 101 A (IEC), 85 A (UL), and 100 A (CSA).
What is the rated voltage for RGW25 terminal blocks?
The rated voltage for RGW25 terminal blocks is 800 V (IEC), 600 V (UL), and 600 V (CSA).
What is the impulse withstand voltage for RGW terminal blocks?
The impulse withstand voltage for RGW terminal blocks is 8000 V.
What is the protection rating for RGW terminal blocks?
The protection rating for RGW terminal blocks is IP10 (IEC) and NEMA 1.
What conductor sizes are compatible with RGW2.5 terminal blocks?
RGW2.5 terminal blocks are compatible with rigid conductors from 0.1 to 2.5 mm² (26 to 14 AWG) and flexible conductors with insulated ferrule from 0.1 to 2.5 mm².
What conductor sizes are compatible with RGW6 terminal blocks?
RGW6 terminal blocks are compatible with rigid conductors from 0.1 to 6 mm² (22 to 10 AWG) and flexible conductors with insulated ferrule from 0.1 to 6 mm².
What is the maximum width of a lug for RGW2.5 terminal blocks?
The maximum width of a lug for RGW2.5 terminal blocks is 7 mm (0.28 in).
Frequently Asked Questions about TE Connectivity
What technical support does TE Connectivity offer?
TE Connectivity offers comprehensive technical support through multiple channels, including a dedicated technical hotline at 1-800-777-3300. The company provides advanced technical support with 3 dedicated support centers, a global technical hotline network, and delivers over 8,000 hours of technical training annually to ensure certified expertise across 25+ languages.
What environmental ratings do TE Connectivity products have?
TE Connectivity products feature robust environmental ratings across multiple standards, including NEMA Type 1, 2, 3, 3R, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. Our enclosures are designed to withstand challenging industrial environments, with operating temperatures ranging from -40°C to 130°C, and include enhanced UV inhibitors for outdoor applications.
What certifications and standards do TE Connectivity products comply with?
TE Connectivity products meet rigorous international certifications and standards across industrial automation applications, including UL (United States), CSA (Canada), CE (European Community), and international safety standards. Our product lines are designed to comply with critical industrial certifications such as NEMA (Types 4, 4X, 6, 6P), IP ratings (IP65, IP66, IP67, IP69K), and industrial communication protocols including PROFINET, EtherNet/IP, and DeviceNet. We ensure comprehensive compliance through active participation in key industrial standards committees and maintaining ISO 9001 quality system certification.
What industries and applications are TE Connectivity products used for?
TE Connectivity products are engineered for critical industrial applications across multiple sectors, including industrial device manufacturing, automotive, robotics, food and beverage, material handling, alternative energy, and commercial vehicle industries. Their solutions span connectivity, power distribution, network communications, and sensor technologies that support complex industrial automation requirements, with a focus on robust connectivity solutions for challenging manufacturing environments.
What are the main product lines offered by TE Connectivity?
TE Connectivity offers a comprehensive range of industrial connectivity solutions including Cable Ties, Cable Cleats, Power Connectors, Grounding Connectors, Terminals, Safety Solutions, Identification Products, and Wiring Duct. Their product lines are designed for robust industrial applications, featuring various connection technologies like wave soldering, spring-cage connections, and mis-insertion protection across multiple electrical and connectivity categories.
What accessories are available for TE Connectivity products?
TE Connectivity offers a comprehensive range of communication and bus accessories for industrial automation systems, including communication terminal boards (CTB810, CTB811), bus extenders (horizontal and vertical models like cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories are designed to enhance connectivity, power distribution, and communication capabilities for HN800 and CW800 controller systems, with options for left/right side mounting, power connections, and network termination.
How are TE Connectivity products typically installed?
TE Connectivity products are typically installed through professional commissioning services that include site audits, precise wiring verification, and both remote and on-site installation support. Our expert service engineers conduct comprehensive installation processes involving system verification, programming, communication testing, and personnel training to ensure optimal performance and reliability of the equipment.