Authorized TE Connectivity Distributor
TE Connectivity 1SNA519004R0100 - E-RGW6-ST END SECTION

TE Connectivity 1SNA519004R0100 E-RGW6-ST END SECTION

Alternate Item Number: 1SNA519004R0100


Documents & Media
BrochureFull Engineering DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

TE Connectivity E-RGW6-ST End Section (SKU: 1SNA519004R0100) is a grey polyamide end section designed for RGW6-ST-1 and RGW6-R1 terminal blocks. This 1.4 mm wide, 85.7 mm tall component secures terminal block ends in low-voltage industrial applications. Compatible with TE Connectivity’s DIN rail terminal block series, it provides structural termination and insulation for cable management systems. The end section meets UL94 V0 flammability standards and operates reliably from -40°C to +100°C. With a net weight of 5.18 g, it is a lightweight yet durable accessory for panel and enclosure installations.
  • Grey polyamide end section for RGW6-ST-1 and RGW6-R1 terminal blocks
  • 1.4 mm width, 85.7 mm height, 38.7 mm depth
  • UL94 V0 flammability rating for safety
  • Operating temperature range: -40°C to +100°C
  • Compatible with TE Connectivity DIN rail terminal blocks

Specifications

Ambient Air Temperature
Operation -40 ... +100 °C
Color
Grey
Declaration of Conformity - CE
1SND225158C1001
ETIM 4
EC000886 - Endplate and partition plate for terminal block
ETIM 5
EC000886 - Endplate and partition plate for terminal block
ETIM 6
EC000886 - Endplate and partition plate for terminal block
Flammability According to UL94
V0
Function
End Sections
Insulation Material
Polyamide
Package Level 1 Depth / Length
88 mm
Package Level 1 EAN
3472600000000
Package Level 1 Gross Weight
0.18 kg
Package Level 1 Height
67 mm
Package Level 1 Units
25 piece
Package Level 1 Width
129 mm
Package Level 2 Depth / Length
400 mm
Package Level 2 Height
300 mm
Package Level 2 Units
1000 piece
Package Level 2 Width
300 mm
Package Level 3 Units
18000 piece
Product Net Depth / Length
38.7 mm
Product Net Height
85.7 mm
Product Net Length
38.7 mm
Product Net Width
1.4 mm
Product Packing Type
Box
RoHS Information
1SND230546F0201
RoHS Status
Following EU Directive 2011/65/EU
Series
E-RGW6-ST
Spacing
1.4 mm
Suitable For
RGW6-R1
EK2.5-3P END SECTION

1SNK705911R0000

EK2.5-3P END SECTION
XT7 PHASE SEPARATORS 200MM, 4 UNITS

ZE1PBF200

XT7 PHASE SEPARATORS 200MM, 4 UNITS
ES4-D2-SF1 END SECTION

1SNK508911R0000

ES4-D2-SF1 END SECTION
E-RGW25 END SECTION

1SNA519005R0000

E-RGW25 END SECTION
E-RGW2.5 END SECTION

1SNA519003R0000

E-RGW2.5 END SECTION
FEDCP END SECTION

1SNA400825R0000

FEDCP END SECTION
CS-RGW-L CIRCUIT SEPARATOR-LARGE

1SNA519201R0000

CS-RGW-L CIRCUIT SEPARATOR-LARGE
ES6-4S END SECTION

1SNK505911R0000

ES6-4S END SECTION

Frequently Asked Questions

What are the key features of RGW Ring Lug Terminal Blocks?

They offer fast and secured wiring with captive nuts in pivoting wings for convenient ring lug connection. Features include a touch-proof design and universal mounting foot.

What wiring sizes are supported by RGW terminal blocks?

RGW terminal blocks support wire sizes from 2.5 mm² (14 AWG) up to 25 mm² (4 AWG).

What is the rated voltage for RGW terminal blocks?

The rated voltage for RGW terminal blocks is 800 V (IEC) and 600 V (UL/CSA).

What is the rated current for RGW2.5 terminal blocks?

The rated current for RGW2.5 terminal blocks is 24 A (IEC), 15 A (UL), and 20 A (CSA).

What is the rated current for RGW6 terminal blocks?

The rated current for RGW6 terminal blocks is 41 A (IEC), 30 A (UL), and 30 A (CSA).

What is the rated current for RGW25 terminal blocks?

The rated current for RGW25 terminal blocks is 101 A (IEC), 85 A (UL), and 100 A (CSA).

What torque is recommended for RGW2.5 terminal block nuts?

The recommended torque for RGW2.5 terminal block nuts is 0.6 to 0.8 N.m (5.3 to 7.1 lb.in).

What torque is recommended for RGW6 terminal block nuts?

The recommended torque for RGW6 terminal block nuts is 0.8 to 1.2 N.m (7.1 to 10.6 lb.in).

Are RGW terminal blocks suitable for harsh environments?

Yes, RGW terminal blocks are qualified for severe environments, including vibration and shock, and comply with IEC 61373 railway standards.

What are the fire safety ratings for RGW terminal blocks?

RGW terminal blocks plastic materials are rated HL3 R22 for EN 45545-2 and I2F2 for NF F 16-101/102, meeting high fire protection standards.

Frequently Asked Questions about TE Connectivity

What technical support does TE Connectivity offer?

TE Connectivity offers comprehensive technical support through multiple channels, including a dedicated technical hotline at 1-800-777-3300. The company provides advanced technical support with 3 dedicated support centers, a global technical hotline network, and delivers over 8,000 hours of technical training annually to ensure certified expertise across 25+ languages.

What environmental ratings do TE Connectivity products have?

TE Connectivity products feature robust environmental ratings across multiple standards, including NEMA Type 1, 2, 3, 3R, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. Our enclosures are designed to withstand challenging industrial environments, with operating temperatures ranging from -40°C to 130°C, and include enhanced UV inhibitors for outdoor applications.

What certifications and standards do TE Connectivity products comply with?

TE Connectivity products meet rigorous international certifications and standards across industrial automation applications, including UL (United States), CSA (Canada), CE (European Community), and international safety standards. Our product lines are designed to comply with critical industrial certifications such as NEMA (Types 4, 4X, 6, 6P), IP ratings (IP65, IP66, IP67, IP69K), and industrial communication protocols including PROFINET, EtherNet/IP, and DeviceNet. We ensure comprehensive compliance through active participation in key industrial standards committees and maintaining ISO 9001 quality system certification.

What industries and applications are TE Connectivity products used for?

TE Connectivity products are engineered for critical industrial applications across multiple sectors, including industrial device manufacturing, automotive, robotics, food and beverage, material handling, alternative energy, and commercial vehicle industries. Their solutions span connectivity, power distribution, network communications, and sensor technologies that support complex industrial automation requirements, with a focus on robust connectivity solutions for challenging manufacturing environments.

What are the main product lines offered by TE Connectivity?

TE Connectivity offers a comprehensive range of industrial connectivity solutions including Cable Ties, Cable Cleats, Power Connectors, Grounding Connectors, Terminals, Safety Solutions, Identification Products, and Wiring Duct. Their product lines are designed for robust industrial applications, featuring various connection technologies like wave soldering, spring-cage connections, and mis-insertion protection across multiple electrical and connectivity categories.

What accessories are available for TE Connectivity products?

TE Connectivity offers a comprehensive range of communication and bus accessories for industrial automation systems, including communication terminal boards (CTB810, CTB811), bus extenders (horizontal and vertical models like cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories are designed to enhance connectivity, power distribution, and communication capabilities for HN800 and CW800 controller systems, with options for left/right side mounting, power connections, and network termination.

How are TE Connectivity products typically installed?

TE Connectivity products are typically installed through professional commissioning services that include site audits, precise wiring verification, and both remote and on-site installation support. Our expert service engineers conduct comprehensive installation processes involving system verification, programming, communication testing, and personnel training to ensure optimal performance and reliability of the equipment.