The TCI V1K362A00 is a 3-phase industrial contactor from TCI, SKU V1K362A00. It is rated for 208-600V and a maximum current of 362A. This contactor features an open NEMA enclosure and includes an integrated dV/dT output filter, designed to mitigate electrical noise and protect connected equipment. It is UL listed, ensuring compliance with safety standards for industrial use. The V1K362A00 is suitable for motor control, HVAC systems, and other heavy-duty industrial applications requiring reliable switching. Its design prioritizes dependable operation with minimal maintenance requirements.
  • 3-Phase Industrial Contactor
  • Voltage Rating: 208-600V
  • Current Rating: 362A
  • Open NEMA Enclosure
  • Integrated dV/dT Output Filter

Specifications

Current Rating
362A
Nema Rating
Open NEMA
Poles
3 Phase
Series
V1K
Voltage Rating
208-600V
MotorGuard, 480V, 362A, 3 Phase

KMG362A00A

MotorGuard, 480V, 362A, 3 Phase
V1K, 208-600V, 200A, 3 Phase

V1K200A03EX

V1K, 208-600V, 200A, 3 Phase
V1K, 208-600V, 21A, 3 Phase

V1K21A01

V1K, 208-600V, 21A, 3 Phase
V1K, 208-600V, 27A, 3 Phase

V1K27A03EX

V1K, 208-600V, 27A, 3 Phase
V1K, 208-600V, 21A, 3 Phase

V1K21A00

V1K, 208-600V, 21A, 3 Phase
V1K, 208-600V, 250A, 3 Phase

V1K250A00

V1K, 208-600V, 250A, 3 Phase
V1K, 208-600V, 21A, 3 Phase

V1K21A03EX

V1K, 208-600V, 21A, 3 Phase
V1K, 208-600V, 35A, 3 Phase

V1K35A03EX

V1K, 208-600V, 35A, 3 Phase

Frequently Asked Questions

What is the voltage spike limit for the V1K filter?

The V1K filter limits voltage spikes to below 1,000 V for applications with lead lengths up to 1,000 ft on 480 V systems.

What are the system voltage and current ranges for the V1K filter?

The V1K filter is compatible with 208 - 600 VAC systems and has a current range of 2 - 750 Amps.

What is the maximum carrier frequency supported by the V1K filter?

The standard V1K filter supports 2 - 4 kHz. Consult TCI for applications over 8 kHz if cable lengths exceed 400 feet.

What is the insulation rating and class of the V1K filter?

The V1K filter has an insulation rating of 600 V Class and an Insulation Class of Class H (180° C) or better.

What is the maximum lead length for the V1K filter?

The V1K filter supports lead lengths up to 1,000 ft. Consult the factory for applications above 1,000 feet.

What are the environmental operating conditions for the V1K filter?

The V1K filter operates in ambient temperatures up to 40° C (104° F) enclosed and at altitudes up to 2,000 m (6,600 ft).

What is the efficiency of the V1K filter?

The V1K filter has an efficiency of greater than or equal to 98%.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.