Overview
- 600kVAR reactive power compensation at 480V
- Full-step control for precise power factor adjustment
- Integrated fuse monitoring with visual indicator
- Built-in circuit breaker for operational safety
- Manufactured by TCI (Germany)
Specifications
Series | PFCA |
Voltage Rating | 480 VAC |

C528G60-HZ-2LE
Reactive Power (Kvar): 60 kVAR Line-Line Voltage (V): 525 V System Frequency (Hz): 60 Standard: UL Losses: < 0.5 Watt/kvar (discharge resistors included) Enclosure Rating: Nema 1 Enclosure Size: CLMD 83 State Indicators: Included Temperature range: -13°F / +130°F Tolerance on capacitance 0% + 15% Overcurrent tolerance: 135% of Rated Current, Continuously Case material: Zinc electroplated mild steel Color: ASA61 or ANSI-61 gray paint finish, powder coat finishFrequently Asked Questions
What is the capacitor tolerance?
The capacitor tolerance is ±5%.
What is the expected operational life of the PF Guard?
The expected life is over 130,000 operating hours.
What is the maximum harmonic voltage allowed?
The maximum harmonic voltage is 5%.
How long does it take for the capacitors to discharge?
The discharge time is less than 1 minute.
What is the operating temperature range for the enclosed unit?
The enclosed unit operates between -10°C (14°F) and 40°C (104°F).
What is the storage temperature range?
The storage temperature range is from -30°C (-22°F) to 60°C (140°F).
What is the maximum relative humidity for operation?
The maximum relative humidity is 95% non-condensing.
What is the maximum operating altitude without derating?
The device can operate up to 1,000m without derating.
What is the voltage rating for the PF Guard?
The PF Guard has a voltage rating of 480 VAC.
What phase configuration does the PF Guard support?
The PF Guard is designed for 3-Phase systems.
Frequently Asked Questions about TCI
What environmental ratings do TCI products have?
TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.
What industries and applications are TCI products used for?
TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.
What are the main product lines offered by TCI?
TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.
What are the key features of TCI products?
TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.
What certifications and standards do TCI products comply with?
TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.
What is TCI's warranty policy?
TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.
What communication protocols do TCI products support?
TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.
What accessories are available for TCI products?
TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.
How are TCI products typically installed?
TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.