Authorized TCI Distributor
TCI KLR360ECB - KLR, 575V, 360A, 350HP

TCI KLR360ECB KLR, 575V, 360A, 350HP


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The TCI KLR360ECB is a 3-phase line inductor designed for industrial power systems requiring stable voltage regulation and harmonic mitigation. Rated at 575V AC and 360A, this NEMA Open construction unit supports motor loads up to 350HP, making it suitable for motor control centers and variable frequency drive applications. With dimensions of 11.38" x 15.00" x 11.00" and a weight of 156 lbs, the KLR360ECB is built for high-current industrial environments. The unit delivers 463 watts of power loss at rated conditions, ensuring efficient thermal performance. Its 3-phase configuration integrates directly into existing industrial setups, providing reliable current stabilization and voltage smoothing. The inductor’s open design promotes natural heat dissipation, reducing the need for forced cooling in most applications. Compatible with 480V and 575V systems, this inductor is optimized for heavy-duty motor applications where consistent power quality is critical. The KLR360ECB is part of TCI’s KLR series, a trusted line of power conditioning components for industrial electrical systems.
  • Rated 575V AC, 360A, 3-phase for high-power industrial applications
  • Supports motor loads up to 350HP (480V/575V systems)
  • NEMA Open construction with dimensions 11.38" x 15.00" x 11.00"
  • 463 watts power loss at rated conditions for efficient thermal performance
  • Open design promotes natural heat dissipation in demanding environments

Specifications

Current Rating
360 A
Nema Rating
OPEN
Nema Rating
NEMA Open
Poles
3-Phase
Series
KLR
Voltage Rating
575 VAC
KLR, 480V, 360A, 300HP

KLR360CCB

KLR, 480V, 360A, 300HP
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
600V Class Iron Core Reactor, Enclosed, 361 Amps, 0.10 Inductance, 60 Hz

CRX0361BE

600V Class Iron Core Reactor, Enclosed, 361 Amps, 0.10 Inductance, 60 Hz
KLR, 480V, 480A, 400HP

KLR480BCB

KLR, 480V, 480A, 400HP
KLR, 690V, 3A, 3 Phase

KLR3EQDDRV

KLR, 690V, 3A, 3 Phase
TCI, S-G, Std, 3-Ph

KLR360ECB5

TCI, S-G, Std, 3-Ph
KLR, 690V, 360A, 300HP

KLR360ECB5V

KLR, 690V, 360A, 300HP
KLR, 480V, 45A, 30HP

KLR45BTB

KLR, 480V, 45A, 30HP

Frequently Asked Questions

What is the voltage and HP range for KDR line reactors?

KDR line reactors are available for voltages from 208 V to 690 V and power ratings from 0.25 HP to 1250 HP.

What types of impedance are available for KDR line reactors?

KDR line reactors are available in Ultra Low, Low, and High Impedance options.

What is the operating temperature range for KDR line reactors?

The ambient temperature range for KDR line reactors is -40°C to 40°C enclosed.

Can KDR line reactors be used on the input and output of a VFD?

Yes, KDR line reactors are constructed to be used on both the input and output of a VFD.

What are the benefits of using KDR line reactors with VFDs?

KDR line reactors help reduce harmonics, protect drives from voltage spikes, and extend motor service life by minimizing insulation stress.

What agency approvals do KDR line reactors have?

KDR line reactors are UL Listed and have cULus agency approvals.

What is the warranty for KDR line reactors?

KDR line reactors come with a lifetime warranty for the life of the drive with which the reactor is installed.

What is the short-term overload rating for KDR line reactors?

KDR line reactors can tolerate 200% rated I for a maximum of 3 minutes.

At what altitude can KDR line reactors operate without derating?

KDR line reactors can operate up to 2,000 m (6,000 ft) without derating.

What is the minimum inductance at 110% and 150% load?

The minimum inductance is 95% L at 110% load and 80% L at 150% load.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.