The TCI KLR12BTB is a 3-phase open input line inductor designed for industrial motor control and VFD applications. Rated at 480V AC, 12A, and supporting 7.5HP motors, this inductor mitigates voltage spikes and reduces harmonic distortion to improve system efficiency and power factor. With a compact 4.00" x 5.00" x 4.00" open design, it installs easily in control panels or enclosures for maintenance and upgrades. The 3-pole configuration ensures balanced 3-phase power distribution. Ideal for VFDs, pumps, fans, and compressors in industrial environments. Open mounting promotes ventilation and accessibility for new installations or retrofits.
  • 3-phase open input line inductor for 480V AC, 12A, 7.5HP motors
  • Compact dimensions: 4.00" H x 5.00" W x 4.00" D, open mounting design
  • Mitigates voltage spikes and reduces harmonic distortion for improved efficiency
  • 3-pole configuration for balanced 3-phase power distribution
  • Compatible with VFDs, pumps, fans, and compressors in industrial environments

Specifications

Connection Type
3-phase
Connection Type
Open Input Line
Current Rating
12 A
Mounting Type
Open
Mounting Type
Open Mounting
Poles
3
Poles
3-pole
Series
KLR
Voltage Rating
480 V
Voltage Rating
480 VAC
KLR, 480V, 12A, 7.5HP

KLR12CTB

KLR, 480V, 12A, 7.5HP
600V Class Iron Core Reactor, Core and Coil, 12 Amps, 4.20 Inductance, 60 Hz

CRX0012CC

600V Class Iron Core Reactor, Core and Coil, 12 Amps, 4.20 Inductance, 60 Hz
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
KLR, 480V, 130A, 100HP

KLR130BCB

KLR, 480V, 130A, 100HP
KLR, 690V, 110A, 100HP

KLR110ECB5V

KLR, 690V, 110A, 100HP
KDR, 575V, 1200A, 1250HP

KDRY41H

KDR, 575V, 1200A, 1250HP
KLR, 480V, 12A, 7.5HP

KLR12ATB1

KLR, 480V, 12A, 7.5HP
KLR, 480V, 12A, 7.5HP

KLR12BTB1

KLR, 480V, 12A, 7.5HP

Frequently Asked Questions

What is the voltage and HP range for KDR line reactors?

KDR line reactors are available for voltages from 208 V to 690 V and power ratings from 0.25 HP to 1250 HP.

What types of impedance are available for KDR line reactors?

KDR line reactors are available in Ultra Low, Low, and High Impedance options.

What is the operating temperature range for KDR line reactors?

The ambient temperature range for KDR line reactors is -40°C to 40°C enclosed.

Can KDR line reactors be used on the input and output of a VFD?

Yes, KDR line reactors are constructed to be used on both the input and output of a VFD.

What are the benefits of using KDR line reactors with VFDs?

KDR line reactors help reduce harmonics, protect drives from voltage spikes, and extend motor service life by minimizing insulation stress.

What agency approvals do KDR line reactors have?

KDR line reactors are UL Listed and have cULus agency approvals.

What is the warranty for KDR line reactors?

KDR line reactors come with a lifetime warranty for the life of the drive with which the reactor is installed.

What is the short-term overload rating for KDR line reactors?

KDR line reactors can tolerate 200% rated I for a maximum of 3 minutes.

At what altitude can KDR line reactors operate without derating?

KDR line reactors can operate up to 2,000 m (6,000 ft) without derating.

What is the minimum inductance at 110% and 150% load?

The minimum inductance is 95% L at 110% load and 80% L at 150% load.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.