Authorized TCI Distributor
TCI KDRMA47L1E3R1 - KDR, 600V, 2 HP, 2.70 Motor Amps

TCI KDRMA47L1E3R1 KDR, 600V, 2 HP, 2.70 Motor Amps


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The TCI KDR Line Inductor, SKU KDRMA47L1E3R1, is engineered for robust 600 VAC applications, providing essential motor protection and performance enhancement. Designed for 3-phase operation, this inductor is rated to support motors up to 2 HP, with a continuous motor current rating of 2.70 Amps and a maximum current handling capability of 3.2 Amps. It features a standard 3% impedance, a critical specification for mitigating voltage notching and reducing harmonic distortion in motor drives, thereby extending motor lifespan and improving operational efficiency. The inductor is housed in a durable Type 3R enclosure, offering protection against falling rain and sleet, making it suitable for various industrial environments. Manufactured in Germany (DE) and UL Listed, this TCI KDR inductor ensures compliance with stringent safety and quality standards. Its reliable construction and precise electrical characteristics make it a dependable choice for motor control systems requiring effective line impedance correction.
  • 600 VAC voltage rating for industrial applications
  • Supports motors up to 2 HP with 2.70A motor current
  • 3.2A maximum current capacity
  • 3% impedance for motor protection and performance
  • Durable Type 3R enclosure for environmental protection

Specifications

Current Rating
2.70 A
NEMA Rating
Type 3R
Series
KDR
Voltage Rating
600 VAC
KDR, 600V, 2 HP, 2.70 Motor Amps

KDRAA43H2E3R1

KDR, 600V, 2 HP, 2.70 Motor Amps
600V Class Iron Core Reactor, Core and Coil, 2.7 Amps, 17.83 Inductance, 60 Hz

CRX02D7BC

600V Class Iron Core Reactor, Core and Coil, 2.7 Amps, 17.83 Inductance, 60 Hz
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
KDR, 600V, 1/4 HP, 0.50 Motor Amps

KDRMA41H1E01

KDR, 600V, 1/4 HP, 0.50 Motor Amps
KDR, 600V, 1/4 HP, 0.50 Motor Amps

KDRMA41L1DR

KDR, 600V, 1/4 HP, 0.50 Motor Amps
KDR, 480V, 3/4 HP, 1.60 Motor Amps

KDRMA4H1E01

KDR, 480V, 3/4 HP, 1.60 Motor Amps
KDR, 480V, 960A, 800HP

KDRX2HE3R

KDR, 480V, 960A, 800HP
KDR, 600V, 1/2 HP, 0.90 Motor Amps

KDRMA43L1E01

KDR, 600V, 1/2 HP, 0.90 Motor Amps

Frequently Asked Questions

What is the voltage and power rating range for KDR line reactors?

KDR line reactors are available for voltages from 208 V to 690 V and power ratings from 0.25 HP to 1250 HP.

What are the available impedance options for KDR line reactors?

KDR line reactors are available in Ultra Low, Low, and High Impedance options.

What is the operating temperature range for KDR line reactors?

The ambient temperature range for KDR line reactors is -40°C to 40°C enclosed.

What is the maximum operating altitude for KDR line reactors without derating?

KDR line reactors can operate up to 2,000 meters (6,000 ft) without derating.

What agency approvals do KDR line reactors have?

KDR line reactors have cULus agency approvals.

What is the warranty period for KDR line reactors?

KDR line reactors come with a lifetime warranty for the life of the drive with which the reactor is installed.

How do KDR line reactors help protect VFDs?

KDR line reactors help reduce harmonics and protect VFDs from harmful voltage spikes.

Can KDR line reactors be used on the output of a VFD?

Yes, KDR line reactors can be used on both the input and output of a VFD.

What is the short-term overload rating for KDR line reactors?

KDR line reactors can tolerate 200% rated I for a maximum of 3 minutes.

What is the minimum L at 110% and 150% load for KDR reactors?

KDR reactors have a minimum 95% L at 110% load and a minimum 80% L at 150% load.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.