Overview

The TCI HSE0100AW30000 is a 100HP industrial power filter designed for 480VAC, 3-phase, 60Hz systems. Manufactured by TCI in Germany, this unit features a UL Type 3R enclosure, providing protection against rain, sleet, and ice for outdoor installations. It filters electrical noise and harmonics to extend equipment lifespan in demanding applications such as HVAC systems, industrial machinery, and power distribution networks. Key specifications include a 480VAC voltage rating, 3 poles, and 60Hz frequency. The UL Type 3R and NEMA Type 3R ratings ensure reliable outdoor performance. No additional accessories are required for standard installations. The HSE series is engineered for continuous operation, reducing electrical interference that can damage sensitive components. Ideal for facilities requiring stable power quality, this filter supports motors, drives, and other inductive loads while maintaining compliance with industrial standards.
  • 100HP power rating for industrial applications
  • 480VAC, 3-phase, 60Hz input compatibility
  • UL Type 3R and NEMA Type 3R enclosure for outdoor protection
  • Filters electrical noise and harmonics for equipment longevity
  • No additional accessories required for standard installations

Specifications

Frequency
60 Hz
NEMA Rating
Type 3R
Poles
3
Series
HSE
Voltage Rating
480 VAC
HGL, 480V, 75HP, 3 Phase

HGL0075AW3C0000

HGL, 480V, 75HP, 3 Phase
HSE Filter, 20HP, 480/3/60, UL Type 3R

HSE0020AW30000

HSE Filter, 20HP, 480/3/60, UL Type 3R
HSE Filter, 7.5HP, 480/3/60, UL Type 1

HSE0008AW11010

HSE Filter, 7.5HP, 480/3/60, UL Type 1
TCI, HSD, 1000HP, 600/3/60

HSD1000CW31000

TCI, HSD, 1000HP, 600/3/60
HSE Filter, 7.5HP, 480/3/60, UL Type 3R

HSE0008AW31010

HSE Filter, 7.5HP, 480/3/60, UL Type 3R
HSE Filter, 10HP, 480/3/60, UL Type 1

HSE0010AW10000

HSE Filter, 10HP, 480/3/60, UL Type 1
HSE Filter, 10HP, 480/3/60, Open

HSE0010AW01010

HSE Filter, 10HP, 480/3/60, Open
HSE Filter, 100HP, 480/3/60, UL Type 1

HSE0100AW11010

HSE Filter, 100HP, 480/3/60, UL Type 1

Frequently Asked Questions

What is the purpose of the HSE passive harmonic filter?

The HSE filter mitigates harmonics produced by Electronically Commutated Motors (ECMs) in HVAC systems, preventing instability and component failure.

What voltage systems is the HSE filter available for?

The HSE filter is available for 480 V systems.

What is the iTDD performance of the HSE filter?

The HSE filter provides 5% iTDD performance across the entire load range.

What communication options are available for the HSE filter?

Communications and data analytics are available via Modbus RTU and EtherNet/IP.

What are the enclosure options for the HSE filter?

Enclosure options include open panel, UL Type 1, and UL Type 3R.

What is the maximum ambient operating temperature for the HSE filter?

The maximum ambient operating temperature is 50°C (122°F) for open enclosures and 40°C (104°F) for enclosed units.

What is the maximum ambient storage temperature for the HSE filter?

The maximum ambient storage temperature for the HSE filter is 60°C (140°F).

What is the maximum humidity for the HSE filter?

The maximum humidity for operating or storage is 95%, non-condensing.

What is the maximum elevation for the HSE filter without derating?

The HSE filter can operate up to 3,300 ft (1,000 m) without derating.

Does the HSE filter ensure compliance with industry standards?

Yes, the HSE filter ensures IEEE 519-2022 compliance.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.