The TCI BH1K5DMF0 is a 1.5kVA encapsulated control power transformer (CPTW series) manufactured in Germany. It converts 220/440V, 230/460V, or 240/480V primary voltage to selectable secondary outputs of 110V, 115V, or 120V at 50/60Hz. Designed for industrial control circuits, it includes a secondary fuse clip for safety and meets UL, CSA, and CE standards. The transformer features a 55°C temperature rise and is ideal for precise voltage transformation in monitoring and automation systems. Primary and secondary fuse clips are available as factory or field-installed options.
  • 1.5kVA encapsulated control power transformer (CPTW series)
  • Primary: 220/440V, 230/460V, or 240/480V (50/60Hz)
  • Secondary: Selectable 110V, 115V, or 120V outputs
  • Secondary fuse clip included; primary/secondary fuse clips optional
  • Meets UL, CSA, and CE standards with 55°C temperature rise

Specifications

Power Rating
1.5 kVA
Secondary Voltage
110, 115, 120 V
Series
BH
Voltage Rating
220x440, 230x460, 240x480 V
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

What is the purpose of the Allient Power CPT industrial control transformer?

The CPT is designed to reduce supply voltages to control voltages for operating electromagnetic components like contactors, solenoids, timers, and relays.

What is the operating voltage range for the primary and secondary sides?

The primary voltage ranges from 115 to 600V, and the secondary voltage ranges from 23 to 240V.

What is the operating temperature range for the CPT transformers?

The ambient temperature range for operation is -20°C (-4°F) to 40°C (104°F).

What agency approvals do these transformers meet?

These transformers meet or exceed standards established by cULus and CSA.

What is the warranty period for the Allient Power CPTs?

Allient Power CPTs come with a 3-year warranty period.

Are the terminals on the transformer safe to touch?

Yes, the transformers feature finger-safe terminals that are integrally built-in.

Can the dual primary voltages be wired using the provided links?

Yes, two parallel jumper links come standard and can be wired for dual primary voltages.

What is the VA rating range for these transformers?

The VA rating for these transformers ranges from 50 to 5,000.

What is the acceptable frequency for operation?

The transformers are designed to operate at a frequency of 50/60Hz.

Can the transformer operate at altitudes above 2,000m without derating?

No, the transformer can operate up to 2,000m (6,600 ft) without derating.

Frequently Asked Questions about TCI

What environmental ratings do TCI products have?

TCI products feature robust environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. Additionally, they meet IEC 60529 IP66 standards, providing exceptional protection against dust, water, and corrosive environments with operating temperatures ranging from -40°C to 130°C.

What industries and applications are TCI products used for?

TCI products are engineered for critical applications across multiple industrial sectors, including HVAC, metals manufacturing, elevators and escalators, marine and shipping, food processing, pulp and paper, and underground construction. Their TorqueDrive Series offers specialized solutions for diverse load types such as fans, pumps, compressors, conveyors, hoists, winders, and synchronized positioning applications, with specific product lines designed for high-performance environments requiring precise torque control, energy efficiency, and robust environmental resistance.

What are the main product lines offered by TCI?

TCI offers four primary product lines: Harmonic Solutions, Motor Protection Solutions, Power Factor Correction Solutions, and High Frequency Noise Solutions. These comprehensive product lines include advanced technologies like HarmonicGuard® Active and Passive Filters, MotorGuard™ Sine Wave Output Filters, PF Guard Capacitor Banks, and KRF 3-Phase EMC Power Line Filters designed for industrial automation and electrical system optimization.

What are the key features of TCI products?

TCI products feature advanced harmonic mitigation solutions including HarmonicGuard® Active and Passive Filters, specialized line and load reactors, and power factor correction technologies. Key capabilities include integrated EMC design, high-endurance capacitors capable of handling 190% rated current, and solutions specifically engineered for harmonically-rich industrial environments like manufacturing facilities, water treatment plants, and facilities with variable frequency drives.

What certifications and standards do TCI products comply with?

TCI products are certified to meet critical North American standards including UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certifications. Our products comply with rigorous safety and performance requirements for industrial automation equipment, with UL Listed Product and Recognized Component classifications ensuring high-quality manufacturing and reliability across multiple industrial applications.

What is TCI's warranty policy?

TCI offers a Limited Warranty policy that requires customers to obtain a Return Material Authorization (RMA) number before returning any products. Returns must be submitted within 30 days of the initial return request to TCI's Germantown, Wisconsin facility. All returned goods are subject to inspection, and restocking charges may apply. Customers should contact TCI's Customer Service for specific warranty details and return instructions.

What communication protocols do TCI products support?

TCI products support a comprehensive range of industrial communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU. These protocols enable flexible network integration, high-performance communication, and seamless connectivity with major PLC systems across diverse industrial automation environments.

What accessories are available for TCI products?

TCI offers a comprehensive range of communication and bus accessories for industrial automation systems. Key accessories include communication terminal boards (CTB810, CTB811), horizontal and vertical bus extenders (cHBX01L/R, HBX01L/R, VBX01T/B), and bus terminators (TER800, TER810). These accessories support connection, power distribution, and signal integrity for HN800 and CW800 device networks, enabling flexible and robust system configurations.

How are TCI products typically installed?

TCI products are typically installed by trained, manufacturer-certified technicians following a comprehensive commissioning process. Installation involves critical steps including work environment inspection, electrical installation checks, internal and external equipment verification, system power-up, and comprehensive operational testing. Authorized installation personnel ensure compliance with industry standards, complete factory acceptance tests, and provide a conformity certificate to guarantee safe and reliable system integration.