Contact for Pricing
Overview
- 1500 Watt DC Power Supply
- Output Voltage: 24 V
- Output Current: 62 Amps
- Single Phase Operation
- Frequency: 47-63 Hz
Specifications
Amperage Rating | 3 x 1.6 AMP |
Application | Industrial Machine Control and Process, Conveying Equipment, Material Handling, Packaging Equipment |
Brand Name | SolaHD |
Cable Size | 16 - 10 AWG Solid AWG |
Efficiency | 94 PCT |
Environmental Conditions | 90 RH Humidity Range PCT |
Frequency Rating | 50/60 HZ |
Fuse Rating | Internally Fused |
Height | 5 |
Length | 4.66 IN |
Material | Metal Housing |
Mounting | DIN Rail |
Phase | 3 |
Special Features | Compact packaging to save space on the DIN rail, Visual diagnostic LEDs for input and output status at a glance, High MTBF means high reliability and long life, Higher efficiency saves energy and lowers amount of heat generated in panel, PowerBoostTM overload capability to start high inrush loads, Accepts Universal voltage 85-264 Vac, 50/60 Hz input, Active Power Factor Correction, Patented DIN rail mounting clip, User Adjustable output voltage accessible via front face, Parallel capability standard, Large, rugged, accessible screw terminals. |
Standard | UL (CANADA AND US), UL 508, UL 60950, CUL, CSA-C22.2, CE |
Type | SDN-C Compact DIN Rail Series |
Voltage Rating | 380 - 400 VAC |
Wattage | 78 WAT |
Width | 7.09 IN |
Package Dimensions (L x W x H) | 19 IN x 12.8 IN x 10.4 IN |
Package Dimensions (L x W x H) | 48.26 cm x 32.512 cm x 26.416 cm |
Package Weight (Imperial) | 12.050 L |
Package Weight (Metric) | 5.466 kg |

3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the output voltage and current for SH30-4QS-0Z?
The SH30-4QS-0Z provides an output voltage of 24 V and an output current of 62 A, with a total power of 1500 W.
What is the input voltage range for the SH30-4QS-0Z?
The SH30 series, including the SH30-4QS-0Z, accepts a single-phase input voltage range of 90–264 Vac or 120–300 Vdc.
What is the operating temperature range for this power supply?
The operating temperature range for the SH30-4QS-0Z is -40 °C to +70 °C ambient. Each output must be derated by 2.5% per degree from 50 °C to 70 °C.
What are the dimensions of the SH30-4QS-0Z case?
The SH30-4QS-0Z case dimensions are 5 x 5 x 11 in (127.0 x 127.0 x 279.4 mm).
What is the warranty period for the SH30-4QS-0Z?
The SH30-4QS-0Z comes with a three-year limited warranty.
What communication interfaces are available for intelligent modules?
Intelligent modules allow the use of I2C communication to monitor and control attributes. CANBUS and RS-485 interfaces are also available as optional features.
What is the maximum torque for single output module connections?
For single output modules, M4 x 8mm screws are used, with a maximum torque of 10 in.-lbs. (1.13 N-m).
What is the power factor correction for the SH30-4QS-0Z?
The power factor correction for the SH30-4QS-0Z is 0.99 typical.
Does the SH30-4QS-0Z require a minimum load?
No, a minimum load is not required for the SH30-4QS-0Z.
What is the hold-up time for the power supply?
The power supply has a minimum hold-up time of 10 ms.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.