Contact for Pricing
Overview
- 300W continuous output, 500VA capacity
- 120V AC input, 50/60Hz compatible
- 4‑minute backup time
- DIN rail mount for easy installation
- Robust chassis and efficient power conversion
Specifications
Amperage Rating | N/A |
Application | Industrial Automation Systems, Critical Microprocessors and PC Based Systems, Robotics and Process Control, Programmable Logic Controllers (PLC), Mission Critical and High Speed Networks |
Back-Up Time | 4.5 |
Battery | Sealed, Maintenance Free Lead Acid |
Battery Type | Sealed, Maintenance Free Lead Acid |
Brand Name | SolaHD |
Environmental Conditions | 1 to 95 Relative Humidity |
Frequency Rating | 50/60 HZ |
Frequency Rating, Maximum | 60 Hz |
Frequency Rating, Minimum | 50 Hz |
Height | 4.88 IN |
Interface | RS232 |
Length | 11.1 |
Mounting | DIN Rail |
Special Features | Rack slide kit for racks with 18-32" deep support rails. |
Standard | Not Listed |
Type | S4KC Accessories |
Voltage Rating | N/A |
Wattage | N/A |
Width | 4.55 IN |
Package Dimensions (L x W x H) | 15.1 IN x 9.9 IN x 8.7 IN |
Package Dimensions (L x W x H) | 38.354 cm x 25.146 cm x 22.098 cm |
Package Weight (Imperial) | 12.600 L |
Package Weight (Metric) | 5.715 kg |

S4K2U10005C
International Model Uninterruptible Power Systems, Capacity: 1000 VA, 900 Watts, Typical Back-up Time: 6/17, Input Plug: IEC 320-C14, Output Receptacle: (6) IEC 320/C13, 230 Vac, Frequency: 50/60 HZ
S1K1500
Uninterruptible Power Supply, Capacity: 1440 VA, 900 Watts, Input Voltage: 115 V +/- 25PCT, Frequency: 50 o 60 Hz +/- 10PCT
S1K320
Uninterruptible Power Supply, Capacity: 320 VA, 240 Watts, Input Voltage: 115 V +20PCT / - 25PCT, Frequency: 50 o 60 Hz +/- 10PCT
SDU850
SDU Series DIN Rail AC UPS, Wattage:510W, Capacity: 850 VA Voltage Rating:120V AC, Frequency Rating:50/60HZ, Back-Up Time: 2 Minutes
SDU850-5
SDU Series DIN Rail AC UPS, Wattage: 510 W, Capacity: 850 VA Voltage Rating:230 V AC, Frequency Rating:50/60HZ, Back-Up Time: 2 Minutes
SDU2024
Features:16 to 12 AWG Wire Range,-20 to 50 DEG C Operating Temperature, Standard:UL (CANADA AND US), UL E61379, UL 508, CE: IEC/EN 60950-1, Voltage Rating:240Vdc, Amperage 20A, Mounting:DIN Rail, Enclosure:IP20, Environmental Conditions:0 to 95Percent Rel
SDUEDC
SDU AC - A Series DIN Rail AC UPS, Enhanced DIN rail clip kit for securing SDUxxxA modes to DIN rail in high vibration or alternate recommended mounting positions
S3K1600
Line-Interactive Uninterruptible Power Supply, Capacity: 1440 VA, 1200 Watts, Volts 120 In/ 120 Out, Frequency: 50/60 HZ, Typical Back-up Time: 3/10, Input Plug: Attached 5-15P, Output Receptacle: (6) 5-15RFrequently Asked Questions
What is the SDU500's power capacity?
The SDU 500A and SDU 500A-5 models have a capacity of 500 VA / 300 W.
What are the input voltage options for the SDU500?
The SDU 500A accepts 120 Vac (+10%, -20%), and the SDU 500A-5 accepts 230 Vac (+/- 15%). Both support 50/60 Hz.
What is the typical battery backup time for the SDU500?
The typical backup time is 4 minutes at full load and 18 minutes at half load.
What type of battery does the SDU500 use?
It uses sealed, non-spillable, maintenance-free lead acid batteries.
What is the operating temperature range for the SDU500?
The SDU500 operates in a temperature range of 0°C to 50°C.
How is the SDU500 UPS typically mounted?
It is designed for mounting on DIN TS35/7.5 or TS35/15 rail systems. Optional brackets are available for chassis or wall mounting.
What is the warranty period for the SDU500?
The SDU500 comes with a two-year limited warranty.
What is the output waveform of the SDU500 in battery mode?
The SDU500 provides a simulated sinewave output in battery mode.
How long does it take to recharge the SDU500 battery?
The battery recharges to 90% capacity from a full discharge in 8 hours.
What is the transfer time to battery power?
The typical transfer time to battery power is less than 8 milliseconds.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.