SolaHD HS10F3AS - Non-Ventilated Automation Transformers, 3 kVA, Primary Amps: 5.0, Secondary Amps: 25.0/12.5, Primary Volts: 600. Volts Secondary: 120/240, Frequency: 60HZ, Single Phase
SolaHD

HS10F3AS

UPC: 783472118281


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD HS10F3AS is a 3 kVA non-ventilated, single-phase automation transformer designed for reliable power conversion in industrial automation environments. This unit features a robust 600 V primary voltage with a primary current rating of 5.0 A, and provides a versatile dual secondary voltage output of 120 V / 240 V with corresponding secondary current ratings of 25.0 A / 12.5 A. Operating at a standard industrial frequency of 60 Hz, the HS10F3AS ensures compatibility with existing power systems. Its non-ventilated, sealed construction minimizes space requirements and eliminates the need for external cooling, reducing maintenance and enhancing operational reliability. This transformer is ideal for applications such as control panels, Programmable Logic Controllers (PLCs), and distributed power systems where precise voltage regulation and stable power delivery are critical. Manufactured in the US by SolaHD, the HS10F3AS meets stringent reliability standards, offering a cost-effective and dependable solution for factories, plants, and any setting demanding high-quality power conversion. The compact footprint and efficient design contribute to overall system efficiency and ease of integration. Key specifications include: * **Capacity:** 3 kVA * **Primary Voltage:** 600 V * **Secondary Voltage:** 120/240 V * **Primary Current:** 5.0 A * **Secondary Current:** 25.0 A / 12.5 A * **Frequency:** 60 Hz * **Phase:** Single-Phase * **Construction:** Non-Ventilated * **Manufacturer:** SolaHD * **SKU:** HS10F3AS This transformer is engineered for consistent performance and longevity in demanding industrial settings, providing stable power for sensitive automation equipment.
  • 3 kVA non-ventilated single-phase automation transformer
  • Primary: 600 V @ 5.0 A
  • Secondary: 120/240 V @ 25.0/12.5 A
  • 60 Hz operating frequency
  • Compact, sealed construction for reduced maintenance and space savings

Specifications

Application
SolaHD encapsulated transformer rated for harsh industrial environments
Brand Name
SolaHD
Enclosure
NEMA 3R, Class 1 Div 2 Group A,B,C and D
Frequency Rating
60 HZ
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
60 Hz
Height
12 IN
Input Current, Maximum
3.33
Input Voltage
600 Volts Primary VAC
KVA Rating
3
Length
7 IN
Maximum Input Current
3.33 AMP
Maximum Output Current
16.7/8.33 AMP
Number Of Phases
1
Output Current, Maximum
16.7/8.33
Output Voltage
120/240 Volt Secondary VAC
Special Features
.500 - 45 kVA units are capsulated with electrical grade silica and epoxy for industrial applications. Rolled steel enclosure.;Copper lead wire terminations;Electrostatically shielded for quality power on sizes 1 kVA and larger;UL Listed/NEMA Type 3R encapsulated enclosure for indoor and outdoor service
Special Features
UL Listed/NEMA Type 3R encapsulated enclosure for indoor and outdoor service; Electrostatically shielded for quality power on sizes 1 kVA and larger; Copper lead wire terminations; .500 - 45 kVA units are capsulated with electrical grade silica and epoxy for industrial applications. Rolled steel enclosure.
Standard
cULus Listed: E25872, E77014, UL 1561 or UL 506, CSA C22.2 No. 47 or No. 66
Temperature Rating
115 DEG C Temperature Rise Under Full Load
Temperature Rating, Maximum
239 F
Temperature Rating, Maximum
115 C
Temperature Rating, Minimum
239 F
Temperature Rating, Minimum
115 C
Type
Automation Transformers - Non-Ventilated 50 VA to 45 kVA
Wattage
2 KVA
Width
10 IN
Package Dimensions (L x W x H)
12.5 IN x 13.5 IN x 7.9 IN
Package Dimensions (L x W x H)
31.75 cm x 34.29 cm x 20.066 cm
Package Weight (Imperial)
55.500 L
Package Weight (Metric)
25.175 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

What is the kVA rating and phase of the HS10F3AS transformer?

The HS10F3AS is a 3 kVA single-phase transformer.

What are the primary and secondary voltages for HS10F3AS?

The HS10F3AS has a 600 Volt primary and a 120/240 Volt secondary, operating at 60 Hz.

What are the dimensions and weight of the HS10F3AS?

The HS10F3AS measures 12.00 in high, 10.00 in wide, and 7.00 in deep, with an approximate ship weight of 66.0 lbs.

What are the primary and secondary amperages for HS10F3AS?

The HS10F3AS has a primary amperage of 5.0 Amps and secondary amperages of 25.0/12.5 Amps.

What type of transformer is the HS10F3AS and where can it be used?

The HS10F3AS is a single-phase, encapsulated dry type distribution transformer suitable for indoor and outdoor service in hazardous and harsh industrial environments.

What is the enclosure rating for the HS10F3AS transformer?

The HS10F3AS features a UL Listed/NEMA Type 3R encapsulated enclosure, protecting it from dust and moisture, and providing shock and vibration resistance.

Is the HS10F3AS compliant for hazardous locations?

Yes, it complies with NEC for Class I, Division 2, Group A, B, C and D locations when installed in compliance with NEC 501.100 (B).

What is the insulation class and temperature rise for the HS10F3AS?

The HS10F3AS uses a UL Class 200˚C insulation system with a 115˚C temperature rise under full load.

Does the HS10F3AS transformer include electrostatic shielding?

Yes, the HS10F3AS, being 3 kVA, is electrostatically shielded for quality power.

What type of wiring terminations does the transformer use?

The HS10F3AS transformer uses copper lead wire terminations.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.