SolaHD E5HF150S - SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 150 KVA, Primary Voltage 480 V, Secondary Voltage  240 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 115 Degrees C, Connection Delta-Delta W/ Ct, Winding Aluminium, Enclosure Nema Type 1
SolaHD

E5HF150S

UPC: 783472148882


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD E5HF150S is a 150 KVA ventilated distribution transformer specifically engineered for industrial power distribution applications. This unit operates with a primary voltage of 480 V and delivers a secondary voltage of 240 V. It is designed for a 60 Hz frequency and functions within a 3-phase electrical system. The transformer employs a Delta-Delta connection configuration, which includes CT (Current Transformer) integration, contributing to improved voltage regulation and robust fault protection, thereby ensuring consistent and reliable power delivery to connected equipment. The internal windings of the SolaHD E5HF150S are constructed from aluminum. This material choice facilitates efficient heat dissipation, which is crucial for maintaining optimal operating temperatures and extending the overall operational lifespan of the transformer. The transformer is housed within a NEMA Type 1 enclosure. This enclosure is designed to provide substantial protection against various environmental factors, making the unit well-suited for deployment in indoor industrial environments. Demonstrating adherence to regulatory requirements, this transformer is DOE 10 CFR P431 - DOE 2016 compliant. Furthermore, it holds UL Listing E25872, signifying that it has met rigorous safety and performance standards established by Underwriters Laboratories. The secondary winding of the E5HF150S is equipped with 7 taps. This feature allows for precise voltage adjustment, enabling users to fine-tune the output voltage to accommodate a range of variable load conditions and maintain optimal system performance. The SolaHD E5HF150S is built with a focus on durability, safety, and operational efficiency, positioning it as a dependable and high-performing solution for demanding industrial power applications. The transformer has a temperature rating of 115 Degrees C.
  • 150 KVA capacity for industrial power distribution
  • 480 V primary to 240 V secondary voltage
  • 3-phase, 60 Hz operation
  • Delta-Delta connection with CT for reliable power
  • Aluminum windings for efficient heat dissipation
  • NEMA Type 1 enclosure for indoor protection
  • DOE 10 CFR P431 - DOE 2016 compliant
  • UL Listed E25872
  • 7 taps for precise voltage adjustment
  • Manufacturer: SolaHD

Specifications

Application
Any situation where the available voltage must be changed to accommodate the voltage required by the specific electrical circuit or connected equipment.
Brand Name
SolaHD
Connection Type
Delta-Delta with CT
Cooling
AA
Efficiency
98.83 Percent
Enclosure
NEMA TYPE 1
Frequency
60 Hz
Frequency Rating
60 HZ
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
60 Hz
Height
44 IN
Insulation Class
220 DEG C
KVA Rating
150 KVA
Length
33 IN
Material
aluminium
Mounting
FLOOR
NEMA Rating
Type 1
Number Of Phases
3
Number Of Taps
7
Poles
3 Phase
Primary Voltage
0.48 kV
Secondary Voltage
0.24 kV
Special Features
DOE 10 CFR p431 - DOE 2016 Compliant
Standard
UL Listed E25872
Temperature Rating
115 Degrees C
Temperature Rating, Maximum
239 F
Temperature Rating, Maximum
115 C
Temperature Rating, Minimum
239 F
Temperature Rating, Minimum
115 C
Type
Ventilated Distribution Transformer
Type of Transformer
Ventilated Distribution Transformer
Voltage Rating
480/240 VAC
Width
21 IN
Winding
ALUMINIUM
Package Dimensions (L x W x H)
40 IN x 40 IN x 55 IN
Package Dimensions (L x W x H)
101.6 cm x 101.6 cm x 139.7 cm
Package Weight (Imperial)
1002.000 L
Package Weight (Metric)
454.507 kg
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 75 KVA, Primary Voltage 480 V, Secondary Voltage  240 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Delta W/ Ct, Winding Aluminium, Enclosure Nema Type 1

E5H75S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 75 KVA, Primary Voltage 480 V, Secondary Voltage 240 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Delta W/ Ct, Winding Aluminium, Enclosure Nema Type 1
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 500 KVA, Primary Voltage 480 V, Secondary Voltage  208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1

K4E2H500S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 500 KVA, Primary Voltage 480 V, Secondary Voltage 208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 75 KVA, Primary Voltage 480 V, Secondary Voltage  480 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1

E81H75S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 75 KVA, Primary Voltage 480 V, Secondary Voltage 480 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 45 KVA, Primary Voltage 480 V, Secondary Voltage  208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1

K4E2H45S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, UL Listed E25872, 45 KVA, Primary Voltage 480 V, Secondary Voltage 208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 15  KVA, Primary Voltage 480 V, Secondary Voltage  208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1

E2H15S

SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 15 KVA, Primary Voltage 480 V, Secondary Voltage 208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 150 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.