SolaHD 23-23-250-8 - Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:5000VA, Primary Voltage:120/208/240V/480 AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ, Single Phase
SolaHD

23-23-250-8

UPC: 783472220908


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 23-23-250-8 is a high‑performance 5000VA industrial transformer designed for demanding power‑distribution applications. With a robust 40 dB common‑mode/transverse‑mode noise attenuation, it minimizes electromagnetic interference, ensuring clean and reliable operation in data‑center, manufacturing, and process‑control environments. Galvanic isolation provides a safe separation between primary and secondary circuits, protecting equipment and personnel from voltage surges and ground loops. The transformer meets UL 1012 and CSA safety standards, giving confidence in compliance and long‑term durability. Its primary voltage range of 120/208/240 V/480 AC and secondary voltage of 120/240 V accommodate a wide variety of industrial power configurations, while the 60 Hz frequency rating aligns with standard North American power systems. Whether used to power PLCs, motor drives, or control panels, the SolaHD 23-23-250-8 delivers reliable performance, low noise, and enhanced safety, making it an ideal choice for high‑reliability installations.
  • 40 dB Common Mode/Transverse Mode Noise Attenuation
  • Galvanic Isolation
  • UL 1012/CSA Compliant
  • 120/208/240V/480 AC Primary Voltage
  • 120/240V AC Secondary Voltage

Specifications

Amperage Rating
3000 VA
Application
Industrial Automation and Control Equipment Power PLCs, Broadcast Equipment, Photo Processing Equipment
Brand Name
SolaHD
Efficiency
Up to 92% at Full Load PCT
Frequency
60 Hz
Frequency Rating
60 HZ
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
60 Hz
Mounting
Bracket
Number Of Phases
1
Number Of Taps
10
Operating Temperature
-20 to 50 degrees C
Operating Temperature, Maximum
122 F
Operating Temperature, Maximum
50 C
Operating Temperature, Minimum
-4 F
Operating Temperature, Minimum
-20 C
Phase
1
Primary Voltage
120/208/240/480 VAC
Regulation
+/-1 PCT
Secondary Voltage
120/240 VAC
Series
23 Series
Size
19 High x 13 Wide x 10 Deep IN
Special Features
Superior voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Hardwired, Acts as step-up/step-down transformer, Galvanic isolation, Noise attenuation 40 dB
Standard
UL 1012, CSA, ANSI/IEEE C62.41
Type
CVS Hardwired Series - Constant Voltage Transformers
Voltage Rating
120/208/240V/480 AC (Primary), 120/240V AC (Secondary)
Package Dimensions (L x W x H)
16 IN x 34 IN x 16 IN
Package Dimensions (L x W x H)
40.64 cm x 86.36 cm x 40.64 cm
Package Weight (Imperial)
221.000 L
Package Weight (Metric)
100.246 kg
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:7500VA, Primary Voltage:240V/480 AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ, Single Phase

23-28-275-6

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:7500VA, Primary Voltage:240V/480 AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ, Single Phase
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:500VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,

23-23-150-8

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:500VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:3000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,

23-23-230-8

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:3000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:2000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,

23-23-220-8

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:2000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:120VA, Primary Voltage:120/240V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

23-22-112-2

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:120VA, Primary Voltage:120/240V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:60VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

23-13-060-2

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:60VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:250VA, Primary Voltage:120/240/480V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

23-23-125-8

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:250VA, Primary Voltage:120/240/480V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:1000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,

23-23-210-8

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:1000VA, Primary Voltage:120/208/240/480V AC, Secondary Voltage:120/240V AC, Frequency Rating:60HZ,
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:30VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

23-13-030-2

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:30VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

Frequently Asked Questions

What is the primary function of the CVS Series?

The CVS Series provides superior power conditioning by recreating a well-regulated sinusoidal waveform, isolating equipment from input disturbances like impulses, sags, and brownouts.

What voltage regulation does the CVS Series offer?

The CVS Series offers superior voltage regulation of ±1%. This tight regulation is achieved using ferroresonant transformer technology.

What power disturbances does the CVS Series protect against?

It protects against impulses, swells, brownouts, sags, and severe waveform distortion. It provides a complete solution against these power quality disturbances.

What are typical applications for the CVS Series?

Typical applications include industrial automation and control equipment, PLCs, analytical laboratory equipment, photo processing, and sound/recording systems.

Does the CVS Series provide surge protection?

Yes, the CVS Series includes surge protection tested to ANSI/IEEE C62.41, Class A & B waveform standards.

Does the CVS Series require maintenance?

No, the CVS Series requires no maintenance. It has a typical mean time between failure of 25 years.

What is the warranty period for the CVS Series?

The CVS Series comes with a 10-year limited warranty.

What are the operating temperature limits?

The operating temperature range is -20° to 50°C, with humidity less than 95% non-condensing.

What is the storage temperature range?

The storage temperature range is -20° to 80°C, with humidity less than 95% non-condensing.

What is the minimum recommended load for the unit?

It is recommended that the unit run at a minimum of 40-50% load. The minimum loading specification is 40%.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.