SolaHD 23-13-030-2 - Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:30VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase
SolaHD

23-13-030-2

UPC: 783472220007


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 23-13-030-2 is a 30VA isolation transformer designed for industrial and commercial applications requiring effective noise suppression and reliable power isolation. This single-phase unit operates at 120V AC on both primary and secondary sides with a frequency rating of 60 Hz. It provides 40 dB of noise attenuation for both common mode and transverse mode interference, significantly reducing electrical noise that can impact sensitive equipment. Galvanic isolation is a key feature, ensuring a safe electrical separation between the primary and secondary circuits, which protects personnel and downstream devices from voltage fluctuations and ground loops. Compliance with UL 1012 and CSA standards underscores its adherence to stringent safety and quality requirements. SolaHD's precise engineering ensures consistent performance, low loss, and extended service life. This transformer is an ideal choice for applications such as data centers, industrial automation, and power distribution networks where reliable power conditioning and compliance are critical. Its robust construction and certified safety features make it a dependable component in demanding operational environments. The 23-13-030-2 features a 30VA wattage rating, a primary voltage of 120V AC, and a secondary voltage of 120V AC. Its frequency rating is 60Hz, and it is a single-phase unit. The transformer offers 40 dB of noise attenuation in both common mode and transverse mode. It also provides galvanic isolation and meets UL 1012 and CSA standards.
  • 30VA Wattage Rating
  • 40 dB Common Mode/Transverse Mode Noise Attenuation
  • Galvanic Isolation for Safety and Protection
  • Primary and Secondary Voltage: 120V AC
  • Frequency Rating: 60 Hz
  • Single Phase Operation
  • UL 1012 and CSA Certified

Specifications

Amperage Rating
30
Application
Industrial Control Circuits and Components, Instrumentation, Drives, CNC Machinery, Equipment for food industry, Microprocessor Circuits, Analog Circuits, Noise sensitive Circuitry and Sensors
Brand Name
SolaHD
Efficiency
Up to 92% at Full Load
Enclosure
Case H2
Frequency Rating
47 to 63 HZ
Height
4 IN
Length
6.5 IN
Mounting
Bracket
Number Of Taps
2
Operating Temperature
-20 to 50 degrees C
Phase
1
Primary Voltage
120
Regulation
+/-1
Secondary Voltage
120
Size
7 High x 4 Wide x 5 Deep
Special Features
Easy-to-install screw terminal connections, Cover options, Industry standard footprint, Universal input and approvals (115/230 Vac), Low noise, extremely quiet DC output. For noise sensitive or analog circuitry. Fast transient response. Ideal for test applications. Built-in OVP on 5 V models and optional on 12, 15 and 24 V models. Automatic resetting overload protection. Short circuit protected.
Standard
UL Recognized Component, ITE, UL 60950-1, CSA Certified, ITE CSA C22.2 CSA 60950-1, CE, IEC60950-1
Type
Silver Line Series - Single & Multi-Output Linears
Voltage Rating
100, 120, 220, 230, 240 Selectable VAC
Width
1.62 IN
Package Dimensions (L x W x H)
8 IN x 13.1 IN x 10.4 IN
Package Dimensions (L x W x H)
20.32 cm x 33.274 cm x 26.416 cm
Package Weight (Imperial)
7.300 L
Package Weight (Metric)
3.311 kg
Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:60VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

23-13-060-2

Features:40 DB (Common Mode/Transverse Mode) Noise Attenuation, Galvanic Isolation, Standard:UL 1012, CSA, Wattage:60VA, Primary Voltage:120V AC, Secondary Voltage:120V AC, Frequency Rating:60HZ, Single Phase

Frequently Asked Questions

What is the primary function of the CVS Series?

The CVS Series provides superior power conditioning by recreating a well-regulated sinusoidal waveform, isolating equipment from input disturbances like impulses, sags, and brownouts.

What is the input voltage tolerance for the CVS Series?

For continuous full load, the input voltage tolerance is +10% to -20% of nominal. For temporary surges or sags, it is +20% to -35% of nominal.

Does the unit act as a step-up/step-down transformer?

Yes, the CVS Series acts as a step-up/step-down transformer and provides galvanic isolation for circuit protection.

What is the efficiency of the CVS Series?

The CVS Series has an efficiency of up to 92% at full load.

What certifications does the CVS Series have?

The CVS Series is UL Listed (UL 1012), CSA C22.2 No. 107.1, and RoHS Compliant.

What is the minimum recommended load for the unit?

It is recommended that the unit run at a minimum of 40-50% load. The minimum loading specification is 40%.

What is the storage temperature range?

The storage temperature range is -20° to 80°C, with humidity less than 95% non-condensing.

What are the operating temperature limits?

The operating temperature range is -20° to 50°C, with humidity less than 95% non-condensing.

What is the warranty period for the CVS Series?

The CVS Series comes with a 10-year limited warranty.

Does the CVS Series require maintenance?

No, the CVS Series requires no maintenance. It has a typical mean time between failure of 25 years.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.