Contact for Pricing
Overview
- 5mm travel distance with AgNi (silver-nickel) contacts for high conductivity and low resistance
- Push-in connection (0.75–2.5 mm²) for tool-free, fast installation and reduced labor time
- Rated insulation voltage: 600V (AC) / 400V (DC), thermal current: 16A
- Mechanical lifetime: 1 million cycles; electrical lifetime: 100,000 cycles at rated load
- Forced-opening contact design per EN 60947-5-1 Annex K for safety and reliability
- Operating temperature: -25°C to 55°C; storage temperature: -50°C to 85°C
- DIN rail mounting compatible for modular control systems and industrial panels

ESE845
The Schlegel Elektrokontakt ESE845 is a high-performance industrial component designed for reliable electrical connections and control systems. Engineered for durability and precision, this product ensures seamless integration into industrial applications, offering enhanced performance and operational efficiency. Its robust construction and advanced technology make it ideal for demanding environments, providing long-term reliability and reduced downtime. Whether used in manufacturing, automation, or power distribution, the ESE845 delivers consistent performance, making it a trusted choice for industrial professionals.
P59419-B21
Enlogic by nVent G3 Metered Switched 3-phase 22kVA/Outlets (24) C13 (24) Combo C13/C19 PDU for HPE
L76070M1200C
DDB-145, Outdoor Coupling Capacitive Voltage Transformer, Nominal System Voltage=138kV, BIL=650kV, Bushing Creep/Strike=179"/47", Ratio=700/1200:1:1, Accuracy=0.3 0,W,X,M,Y,Z, Thermal Rating=1000VA, Primary Voltage=80500V, Secondary Voltage=115/67.08V (2), Capacitance=7000pF, Voltage Ground Switch=YES, Carrier Accessories=YES
FP102E/SFP/BT90/52
Industrial 10 Gigabit SFP Media Converter with IEEE802.3BT Power Injector (90W); 1G/10GBase-T (RJ45); 1G/10GBase-X (SFP); -40 ot 75C; 12-56VDC Input
FFIN-2-4FR-CA-NS
Foundation Fieldbus, Conduit Adapter, 2 ports, 4 Pole 7/8UN2 Female Straight, 4A, No SwitchFrequently Asked Questions
What is the continuous thermal current for the DSTOSDE contact block?
The continuous thermal current for the DSTOSDE contact block is 10 A.
What is the required stripping length for the wires connected to DSTOSDE?
The required stripping length for the wires is 8 to 10 mm.
What is the DSTOSDE contact block's primary function?
The DSTOSDE is a modular contact block with a positive opening contact and a safety contact for failure switch off. It opens when separated from the e-stop head.
What approvals does the DSTOSDE contact block have?
The DSTOSDE contact block has approvals including CCC, cCSAus, CE, DNVGL, TÜV_Süd, and UKCA.
What is the contact type and degree of protection for DSTOSDE?
The contact type is 1 NC (+ 1 NO) and the degree of protection is IP20.
What is the operating travel and connection type for DSTOSDE?
The operating travel is 5 mm, and it uses a push-in connection for wires from 0.75 to 2.5 mm².
What are the maximum storage and operating temperatures for DSTOSDE?
The maximum storage temperature is -50°C to 85°C, and the maximum operating temperature is -25°C to 55°C.
What is the mechanical and electrical life of the DSTOSDE contact block?
The mechanical life is 50,000 switching cycles, and the electrical life at rated load is also 50,000 switching cycles.
What is the minimum voltage required for DSTOSDE operation?
The minimum voltage required for operation is 24 V.
What is the bouncing time for the NC contact in DSTOSDE?
The bouncing time for the NC contact is less than 10ms.