- Category 6A UTP copper cable for 10GBASE-T applications
- 23 AWG conductors with flame-retardant HDPE insulation
- Integrated pair divider and patent-pending MaTriX tape for AXT protection
- LSZH (IEC 60332-3) jacket for enhanced fire safety
- Blue color for easy identification, PoE and HDBaseT compliant
Specifications
Color | Blue |
Conductor Material | Copper |
Construction | U/UTP |
Insulation Material | High-Density Polyethylene |
Jacket Material | High-Density Polyethylene |
Length | 1000 FT |
Number of Conductors | 4 |
Outside Diameter | 0.31 In. |
Resistance | Flame-Resistant |
Standard | Exceeds the ANSI/TIA-568-C.2 Category 6A and IEC 61156-5 Category 6A standards for supporting 10GBASE-T transmission over twisted-pair cabling systems, HDPE (LSZH-3): IEC 60332-3-25 (-3d), NBN C 30-004 (F2), 60754-2, 61034-2 PVC (CM): IEC 60332-1 and UL 1 |
Temperature Rating | 167 F |
Type | Copper Cable |
Voltage Rating | 80 V |
Weight | 39/1000 ft. lb |
Package Dimensions (L x W x H) | 15.8 IN x 15.8 IN x 11.7 IN |
Package Weight (Imperial) | 48.14 lbs |

PFL6X04BU-CEG
The TX6A Cat 6A shielded F/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by an overall metallic foil shield within a HDPE flame-retardant jacket. The blue, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.
PSM7004BU-KEM
IndustrialNet Copper Cable, Industrial Ethernet, Harsh Environment, Marine Grade, Category 7, 4-pair, 23 AWG stranded, S/FTP, LSZH, Oil and fuel resistant, SHF1 compliant, HDPE jacket, Blue, DNV/GL and ABS certified, 3280ft/1000m reel
PUR6004BU-W
The TX6000 Enhanced Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by a HDPE flame-retardant jacket. The blue, riser (CMR) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.
PUL6AV04BU-EG
The TX6A Cat 6A U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by a Vari-MaTriX Tape and a flame-retardant HDPE flame-retardant jacket. The blue, LSZH (IEC 60332-3, EuroClass Dca-s2,d2,a1) cable is supplied 305 meters (1,000 feet) to a reel.
PUR6004BU-FE
The TX6000 Enhanced Cat 6 U/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by a HDPE flame-retardant jacket. The blue, riser (CMR) cable is supplied 1,000 feet (305 meters) to an easy pay-out carton.
PUZ6AM04WH-CEG
Category 6A Advanced MaTriX, 4-Pair, 23AWG copper cable, U/UTP, LSZH (Low Smoke Zero Halogen, IEC60332-3), White, Euro pallet, 1000ft/305m
PFL6X04WH-CEG
The TX6A Cat 6A shielded F/UTP copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The conductors are twisted in pairs and separated by a cross divider. All four pairs are surrounded by an overall metallic foil shield within a HDPE flame-retardant jacket. The white, LSZH (IEC 60332-3) cable is supplied 305 meters (1,000 feet) to a reel.
PFO6X04BL-CEG
The TX6A Cat 6A shielded copper cable is a F/UTP Outside Plant (OSP) cable. The cable has a gel-filled construction to prevent moisture migration in underground and wet applications and a wide temperature range for extreme weather environments. The copper conductors are twisted in pairs, separated by a pair separator, covered with an overall foil shield and a UV-resistant and abrasion-resistant polyethylene (PE) jacket. This product is to be used in duct and conduit installations only.
PUO6C04BL-CEG
The TX6 U/UTP Outside Plant (OSP) Copper Cable is constructed of 23 AWG copper conductors with PE insulation. The cable has a gel-filled construction to prevent moisture migration in underground and wet applications. The conductors are twisted in pairs and covered by a UV-resistant and abrasion-resistant HDPE flame-retardant jacket. This cable is for duct and conduit installations only.
IFRH5C04BL-UG
The Cat 5e UTP copper cable is constructed of 24 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs and wrapped with a foam polypropylene tape to form a core. All four pairs are covered with an industrially rated black PVC jacket which is oil and sunlight resistant and flame retardant. This cable is rated for panel or on-machine applications where space is shared with 600 V high voltage cables. The cable is supplied 305 meters (1,000 feet) to a reel and black.
PFR5504BU-UY
Shielded copper cable, category 5e F/UTP, riser (CMR), 4-pair, conductors are 24 AWG construction with polyethylene insulation, twisted in pairs, surrounded by an overall polyester aluminum foil with a stranded copper drain wire and protected by a flame-retardant PVC jacket, blue.Frequently Asked Questions
What is the cable's temperature rating?
The cable operates between -4°F to 167°F (-20°C to 75°C) during operation and can be installed at temperatures from 32°F to 140°F (0°C to 60°C).
Is the cable PoE compliant?
Yes, the cable meets IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt for PoE applications.
What is the maximum installation tension for the cable?
The maximum installation tension for the cable is 25 lbf (110 N).
What is the maximum operating voltage for the cable?
The maximum operating voltage for the cable is 80V.
What standards does the cable exceed?
The cable exceeds ANSI/TIA-568-C.2 Category 6A and ISO 11801 Class EA standards for supporting 10GBASE-T transmission.
What is the cable diameter for FEP Plenum?
The cable diameter for FEP Plenum (CMP) is 0.292 in. (7.4mm) nominal.
What is the weight of the FEP Plenum cable?
The weight of the FEP Plenum (CMP) cable is 44 lbs./1000 ft. (20 kg/305m).
What materials are used for cable insulation?
The cable insulation is made of FEP, PE, HDPE, or PVC depending on the type.
What is the minimum bend radius for the cable?
The minimum bend radius for the cable is 4 times the cable diameter.
How is the cable packaged?
The cable is packaged in 1000 ft. (305m) on a reel.
How to Install the TX6A™ and TX6A-SD™ 10Gig™ UTP Copper Cabling System
This guide provides step-by-step instructions for installing the TX6A™ and TX6A-SD™ 10Gig™ UTP Copper Cabling System in compliance with industry standards.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Cable ties, Terminal connectors
- Plan the cable pathways
Design the cable pathways to minimize disruption and allow for future expansion, ensuring the maximum fill capacity does not exceed 40% for initial installation.
- Mount the cables
Securely mount the TX6A™ or TX6A-SD™ cables in the designated pathways, ensuring that the bend radius is maintained at a minimum of four times the cable diameter.
- Terminate the cables
Follow the termination procedures at the patch panel, ensuring that the outer cable jacket is as close as possible to the point of termination and that the last twist is no further than 0.5 inches from the termination point.
- Verify cable connections
Use a multimeter to verify that all connections are secure and that there are no shorts or open circuits in the installed cables.
- Organize and secure cables
Use cable ties to bundle and secure the cables, ensuring that they are not pinched or crushed and that there is at least 12 inches of slack at the work area.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.