
Contact for Pricing
Overview
- 12-fiber ribbon OM4 pigtail with 250µm coating
- Ultra-low insertion loss (IL) for optimal performance
- 6-port duplex LC adapters in aqua color
- Zirconia sleeves for enhanced durability and precision
- Designed for high-density fiber management applications
Specifications
Application | OM4 |
Color | Aqua |
Connection 1 | LC |
Connection 2 | LC |
Connection Type | LC Adapter |
Connector 1 Type* | LC Duplex |
Connector 2 Type* | Unterminated |
Fiber Compatibility* | Ultra OM4 50/125 m |
Fiber Compatibility* | Ultra OM4 50/125µm |
Fiber Count* | 12 |
Length | 12.62 in |
Length | 320.548 mm |
Material | Zirconia |
Type | Fiber Cassette |
Package Dimensions (L x W x H) | 7.8 IN x 4.5 IN x 1.5 IN |
Package Weight (Imperial) | 0.407 lbs |

FHSZA-12-10P
HD FLEX LC SPLICE CASSETTE PRELOADED WITH 12 OM4 LC PIGTAILS (900UM) AND ULTRA LOW IL; 6-PORT DUPLEX LC ADAPTERS IN AQUA COLOR WITH ZIRCONIA SLEEVES
FC2ZO-12-10B2
12-FIBER OM4 TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FHSXO-12-10R
HD FLEX LC SPLICE CASSETTE PRELOADED WITH 12-FIBER RIBBON OM3 PIGTAIL (250UM) AND OPTIMIZED IL; 6-PORT DUPLEX LC ADAPTERS IN AQUA COLOR WITH ZIRCONIA SLEEVES
FC2ZN-24-10B2
OM4 24-FIBER TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, STANDARD LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FC2ZN-12-10B2
12-FIBER OM4, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, STANDARD LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FC2ZN-12-10B1
12-FIBER OM4, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, STANDARD LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B1 (1-1 ARRAY)
FC2ZO-24-10B2
OM4 24-FIBER TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FC2ZO-12-10B1
12-FIBER OM4 TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B1 (1-1 ARRAY)
FC2XO-24-10B2
OM3 24-FIBER TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FC2XO-12-10B1
OM3 12-FIBER TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE, OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B1 (1-1 ARRAY)
FC2XO-12-10B2
OM3 12-FIBER TOTAL, AQUA ADAPTER, ZIRCONIA SPLIT SLEEVE; OPTIMIZED LOW LOSS, LC DUPLEX TO MTP (MALE); METHOD B - B2 (1-12 ARRAY)
FADSCZBU-L
The SC duplex adapter connects two SC connector pairs in one module space and features a blue, singlemode fiber adapter and has zirconia split sleeves. This part (ending in -L) is a pack of 50 adapters.Frequently Asked Questions
What is the maximum fiber capacity per rack unit?
The HD Flex™ Fiber Cabling System supports up to 144 fibers per rack unit.
How does the split-tray design benefit serviceability?
The split-tray design allows servicing of cassettes without disturbing adjacent connections, minimizing circuit disruptions.
What types of fiber trunks are available?
Pre-terminated PanMPO™ Trunk Cable Assemblies are available in multimode or singlemode, with 12-fiber, 24-fiber, and 48-fiber options.
What is the installation requirement for the HD Flex™ system?
The HD Flex™ Fiber Cabling System can be installed by a single technician, simplifying deployment.
What is the purpose of the MPO parking feature?
The MPO parking feature reduces installation time for fiber trunks during cable plant migrations.
What is the maximum fiber capacity of the HD Fusion Fiber Splicing Enclosure?
The HD Fusion Fiber Splicing Enclosure can accommodate up to 576 single fibers and up to 864 ribbon fibers.
How many ports do the cassettes support?
Cassettes are available in either 6-port or 12-port configurations.
What is the design feature for cable management?
The system features side trunk cable management for easy access to cables and connectors.
What types of patch cords are available?
Patch cords are available with Push-Pull LC Duplex or PanMPO Interconnects in various configurations.
What configurations can the enclosures support?
Enclosures can be reconfigured to accept either 6-port or 12-port cassettes and adapter panels.
How to Install the FHSZA-12-10P Fiber Splice Cassette
This guide provides step-by-step instructions for installing and configuring the FHSZA-12-10P Fiber Splice Cassette, ensuring proper fiber management and connection.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Pan-Ty cable ties, Splice sleeves
- Mount the Fiber Adapter Panel
Secure the Fiber Adapter Panel (FAP) to the designated location using mounting screws. Ensure it is level and firmly attached.
- Prepare Incoming Field Cable
Strip the outer jacket of the incoming field cable by 20 inches. Secure the cable using Pan-Ty cable ties, ensuring the maximum cable diameter does not exceed 7.4mm.
- Expose and Clean Fiber Ends
Expose all fiber ends for splicing by stripping off approximately 35mm of coating from each fiber. Wipe the bare fiber with a lint-free tissue soaked in isopropyl alcohol.
- Perform Fiber Splicing
Slide a splice sleeve onto each fiber, cleave the fiber to ensure 10mm of bare fiber extends past the coating, and splice all fibers according to the splicer manufacturer's instructions.
- Route and Secure Spliced Fibers
Route the spliced fibers into the cassette, ensuring they are located under the routing tabs. Secure splice sleeves within the splice organizer.
- Reinstall the Cover
Once all fibers are secured and organized, reinstall the cover of the Fiber Adapter Panel to protect the connections.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.