- 1000V rated for live sealing and insulation of energized cables
- Fast installation in under one minute, replacing greases, tapes, and epoxies
- Thermally stabilized polyolefin with meltable sealant for watertight, airtight protection
- Resists abrasion and corrosion; conforms to irregular shapes for complete insulation
- Qualified to ANSI C119.1-1986 and ICEA electrical withstand test for 1000 volts
- Compatible with lead, steel, aluminum, copper, and standard insulating materials
- Ideal for underground splicing, direct burial, and submersible applications
Specifications
Amperage Rating | 1000 V |
Application | NSI |
Power Frequency | 1 x 1012 ohm-cm |
Power Frequency Withstand Voltage Wet&Dry | 430 V/mil |
Ribs | Black |
Size | 0.71 IN |
Special Features | Heat Shrink End Caps Provide For Efficient And Positive Cable End Sealing |
Standard | ANSI C119.1-1986 Qualified |
Type | Heat Shrink End Cap |
Voltage Rating | 1000V |
Warranty | 1 Year |
Package Dimensions (L x W x H) | 2.5 IN x 0.7 IN x 0.7 IN |
Package Dimensions (L x W x H) | 6.35 cm x 17.78 mm x 17.78 mm |
Package Weight (Imperial) | 0.012 L |
Package Weight (Metric) | 0.005 kg |

HSC-450
Easy-Splice Heat Shrinkable End Cap These caps replace greases, tapes, epoxy, encapsulation, or dips. In most sizes, installation may be accomplished in less than one minute. Heat-shrinkable end caps provide for efficient and positive cable end sealing. Made of thermally stabilized polyolefin, the interior of the HSC is coated with a meltable sealant to assure a watertight seal, complete insulation, abrasion and corrosion resistance. Seals may be affected over lead, steel, aluminum, copper and all standard plastic and elastomeric insulating materials and conduit. HSC end sealing caps are qualified to ANSI C119.1-1986 and rated to ICEA electrical withstand test for 1,000 volts. HSC end sealing caps can be used as a live seal for cables carrying up to 1,000 volts. They can also be used as end seals for storing and pulling de-energized cable.
HSC-195
Easy-Splice Heat Shrinkable End Cap 750 - 1500 MCM These caps replace greases, tapes, epoxy, encapsulation, or dips. In most sizes, installation may be accomplished in less than one minute. Heat-shrinkable end caps provide for efficient and positive cable end sealing. Made of thermally stabilized polyolefin, the interior of the HSC is coated with a meltable sealant to assure a watertight seal, complete insulation, abrasion and corrosion resistance. Seals may be affected over lead, steel, aluminum, copper and all standard plastic and elastomeric insulating materials and conduit. HSC end sealing caps are qualified to ANSI C119.1-1986 and rated to ICEA electrical withstand test for 1,000 volts. HSC end sealing caps can be used as a live seal for cables carrying up to 1,000 volts. They can also be used as end seals for storing and pulling de-energized cable.
HWHS6-40-12
Easy-Splice Heavy Wall Heat Shrink 6-4/0 AWG, 12 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS6-40-6
Easy-Splice Heavy Wall Heat Shrink 6-4/0 AWG, 6 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS20-750-48
Easy-Splice Heavy Wall Heat Shrink 2/0 AWG - 750 MCM, 48 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS8-2-6
Easy-Splice Heavy Wall Heat Shrink 8-2 AWG, 6 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS2-500-9
Easy-Splice Heavy Wall Heat Shrink 2 AWG - 500 MCM, 9 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS8-2-48
Easy-Splice Heavy Wall Heat Shrink 8-2 AWG, 48 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS8-2-12
Easy-Splice Heavy Wall Heat Shrink 8-2 AWG, 12 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS14-6-6
Easy-Splice Heavy Wall Heat Shrink 14-6 AWG, 6 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS2-500-12
Easy-Splice Heavy Wall Heat Shrink 2 AWG - 500 MCM, 12 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. RUS accepted for use as a secondary tap or splice cover. May be used for jacket repair on cables up to 35 kV. Qualified to ANSI C119.1-1986 for underground splicing. Insulate and seal buried electrical connections rated up to 1,000 volts. UL 486D Listed, CSA C22.2. Temperature Rating: 121-135 degrees C, 1,000V. CONNECTORS UP TO 6 INCHES: Recommended cut length = Connector length + 4 inches. CONNECTORS OVER 6 INCHES: Recommended cut length = Connector length + 5 inches.
HWHS2-500-48
Easy-Splice Heavy Wall Heat Shrink 2 AWG - 500 MCM, 48 Inch - 3 Count Made of specially formulated polyolefin irradiated and thermally stabilized to give the material "elastic memory". When a proper amount of heat is directly applied to the shrink sleeve, it will permanently shrink to its original unexpanded diameter tightly cover and "mold" itself into irregular shapes. The interior sleeve is coated with an adhesive that assures a watertight seal after shrinking. For use on standard poly- or elastomeric-insulated/ jacketed cables or lead-jacketed cables, which may include aluminum or steel armoring. UL 486D Listed, CSA C22.2.Frequently Asked Questions about NSI Industries
How are Tork products typically installed?
Tork products are typically installed by trained technicians who follow a comprehensive commissioning process. This includes verifying the work environment, conducting electrical installation checks, performing internal and external equipment inspections, powering on the system, and executing operational tests to ensure compatibility and reliability.
What environmental ratings do Tork products have?
Tork products are designed to meet various environmental ratings, including NEMA Type 4X and Type 6, which provide protection against corrosion, windblown dust, rain, and occasional temporary submersion. These ratings ensure that Tork products can withstand harsh industrial environments while maintaining operational integrity.
What communication protocols do Tork products support?
Tork products support a comprehensive range of communication protocols, including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, and Modbus RTU integrated as standard. These protocols facilitate flexible network integration and high-performance communication across various industrial automation systems.
What are the key features of Tork products?
Tork products are designed with advanced features that enhance efficiency and reliability in industrial applications. Key features include integrated harmonics and EMC design for improved power quality, removable terminals for quick installation, and USB ports for easy troubleshooting. Additionally, Tork solutions emphasize user-friendly setup with application wizards and memory modules for convenient parameter management.
What are the main product lines offered by Tork?
Tork offers a diverse range of products primarily focused on industrial automation, including TORK® Photocontrols, lighting controls, and various electrical components such as enclosures, occupancy sensors, and grounding solutions. These products are designed to enhance efficiency and reliability in commercial and industrial applications.
What technical support does Tork offer?
Tork offers a comprehensive range of technical support services, including 24/7 customer support, on-site service management, and a technical hotline network. With three advanced technical support centers and over 8,000 hours of technical training conducted annually, Tork ensures certified expertise across 25+ languages to assist customers effectively. Their commitment to service is reflected in a 98% Service Level Agreement compliance rate, providing reliable support for all operational needs.
What industries and applications are Tork products used for?
Tork products are utilized across a variety of industries, including food processing, healthcare, hospitality, and manufacturing. They are designed for applications such as hand hygiene, surface cleaning, and dispensing solutions, ensuring efficiency and compliance in environments that require high standards of cleanliness and safety.
What certifications and standards do Tork products comply with?
Tork products comply with UL and cUL certifications, ensuring they meet rigorous safety and performance standards. Additionally, many models are designed to meet NEMA enclosure ratings, providing protection against environmental factors.
How are Remke products typically installed?
Remke products are typically installed through a systematic process that includes site audits to verify proper wiring, followed by remote or on-site commissioning. This commissioning involves installation verification, programming, and communication testing to ensure the system operates reliably and meets design specifications.
What accessories are available for Remke products?
Remke offers a wide range of accessories for their products, including panel mounting kits, fuse holders for voltage inputs, ferrites for communication modules, and current transformers. These accessories enhance the functionality and protection of Remke's industrial automation solutions, ensuring reliable performance in various applications.