Authorized Mersen Distributor
Mersen TR45R-3PK - Fuse TR-R - Class RK5 - Time-Delay 250VAC 250VDC 45A Ferrule Tri-Onic® 3 pack
More images

Mersen TR45R-3PK Fuse TR-R - Class RK5 - Time-Delay 250VAC 250VDC 45A Ferrule Tri-Onic® 3 pack

Alternate Item Number: TR45R-3PK

UPC: 782001333645


Documents & Media
Technical DrawingLine DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen TR45R-3PK is a Class RK5, time-delay fuse designed for reliable overcurrent protection. Engineered with advanced material technology, these Tri-Onic® fuses are ideal for safeguarding motors, transformers, service entrance equipment, feeders, and branch circuits. The proven time-delay characteristic is crucial for safely managing harmless starting currents and the inrush currents inherent in modern motors and transformers, preventing nuisance openings. This fuse offers current-limiting capabilities, ensuring low peak let-through current. Its rejection-style design, when used with recommended fuse blocks, prevents incorrect replacements. The TR45R features a durable fiberglass body for dimensional stability in demanding industrial settings and a high-grade silica filler for rapid arc quenching and effective current limitation. Each fuse is clearly labeled for quick identification and features metal-embossed date and catalog numbers for lasting traceability. This 3-pack provides a convenient supply for essential protection needs. Rated for 250VAC and 250VDC, with an interrupting rating of 200kA AC and 20kA DC, the TR45R-3PK meets UL standard 248-12 and CSA standard C22.2 no. 248.12.
  • Class RK5, Time-Delay Fuse for reliable overcurrent protection
  • Safely handles motor starting and transformer inrush currents
  • Current-limiting with low peak let-through current
  • Durable fiberglass body and high-grade silica filler for harsh environments
  • Rejection-style design prevents replacement errors (with recommended blocks)

Specifications

AC Voltage Rating
250 V
Amperage Rating
45 A
Application
Motor circuits Mains Feeders Branch circuits Transformers Service entrance equipment General-purpose equipment
Body Material
PolyTube
Brand Name
Mersen
Class
Class RK5
Connection
Ferrule
Connection Material
Copper
Connection Type
Ferrule
Current Rating
45A
Interrupt Rating
200 kA
Mounting
Clip
Series
TR-R
Size
3 x 0.81 in
Size
76.2 x 20.65 mm
Size
3 x 0.81;76.2 x 20.65 in;mm
Size
Ferrule
Special Features
Time-delay Current-limiting AC & DC rated Optional solid state SmartSpot blown fuse indicator Time-delay for motor start-ups and transformer inrush currents without nuisance opening Current-limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick brand recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and high current limitation
Standard
UL listed to standard 248-12 File E2137 CSA certified to standard C22.2 no. 248.12 DC listed to UL standard 248 TRS only
Sub Brand
Tri-Onic®
Type
Class RK5
Voltage Rating
250 VAC
Package Dimensions (L x W x H)
3 in x 0.81 in x 0.81 in
Package Dimensions (L x W x H)
76.2 mm x 20.65 mm x 20.65 mm
Package Weight (Imperial)
0.135 lb
Package Weight (Metric)
0.061 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

Frequently Asked Questions

What are the AC and DC interrupting ratings for TR-R fuses?

TR-R fuses have an AC interrupting rating of 200kA and a DC interrupting rating of 20kA.

What are the AC and DC interrupting ratings for TRS-R fuses?

TRS-R fuses have an AC interrupting rating of 200kA. For DC, they are 20kA for 1/10-60A and 100kA for 70-600A.

What applications are Tri-Onic TR and TRS fuses designed for?

These fuses are engineered for overcurrent protection of motor circuits, mains, feeders, branch circuits, transformers, and general-purpose equipment.

What is the primary benefit of the time-delay characteristic?

The time-delay characteristic safely handles harmless starting currents and inrush currents from motors and transformers without nuisance opening.

Does Mersen offer a blown fuse indicator for these fuses?

Yes, an optional solid-state SmartSpot blown fuse indicator is available. To order, add 'ID' to the catalog number.

What are the UL and CSA approval standards for these fuses?

They are UL listed to standard 248-12 (File E2137) and CSA certified to standard C22.2 no. 248.12.

Are TRS-R fuses DC listed to a specific UL standard?

Yes, TRS-R fuses are DC listed to UL standard 248.

What are the voltage ratings for TR-R fuses?

TR-R fuses are rated for 250VAC and 250VDC for .1-2.8A and 35-400A. They are also rated for 160VDC for 3-30A and 450-600A.

What is the amperage range for TR-R and TRS-R fuses?

Both TR-R and TRS-R fuses are available in amperage ratings from 1/10 to 600A.

Are there any features to prevent replacement errors?

Yes, the rejection-style design prevents replacement errors when used with the recommended fuse blocks.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.