Authorized Mersen Distributor
Mersen TR110R - Fuse TR-R - Class RK5 - Time-Delay 250VAC 250VDC 110A Blade Tri-Onic®
More images

Mersen TR110R Fuse TR-R - Class RK5 - Time-Delay 250VAC 250VDC 110A Blade Tri-Onic®

Alternate Item Number: TR110R

UPC: 782001748043


Documents & Media
Technical DrawingLine DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen TR110R is a Class RK5 time-delay fuse engineered for reliable overcurrent protection in industrial applications. Rated for 250VAC and 250VDC at 110A, this Tri-Onic® fuse is specifically designed to handle harmless motor start-up currents and transformer inrush without nuisance tripping. Its current-limiting design significantly reduces peak let-thru current, minimizing stress on downstream equipment and enhancing system safety. The rejection-style design ensures only compatible fuse blocks can be used, preventing incorrect replacements that could compromise protection. The fiberglass body provides exceptional dimensional stability in harsh environments, while the high-grade silica filler enables fast arc quenching for rapid fault interruption. Optional SmartSpot® blown fuse indication technology is available for quick fault detection, improving maintenance efficiency. UL/CSA listed to standard 248-12 (File E2137), this fuse is ideal for motor circuits, service entrance equipment, feeders, and branch circuits. It is compatible with standard fuse blocks such as the 20306R or 60306R for 250V/600V systems, ensuring seamless integration into existing installations. The fuse’s robust construction and advanced features make it a dependable choice for critical industrial protection applications.
  • Class RK5 time-delay fuse for motor and transformer protection
  • Rated 250VAC and 250VDC, 110A current capacity
  • Handles harmless start-up and inrush currents without nuisance tripping
  • Current-limiting design reduces peak let-thru current
  • Rejection-style design prevents incorrect replacements

Specifications

AC Voltage Rating
250 V
Amperage Rating
110 A
Application
Motor circuits Mains Feeders Branch circuits Transformers Service entrance equipment General-purpose equipment
Body Material
PolyTube
Brand Name
Mersen
Class
Class RK5
Connection
Blade
Connection Material
Tin-Plated Copper
Interrupt Rating
200 kA
Mounting
Clip
Size
7.13 x 1.56;181.102 x 39.7 in;mm
Size
7.13 x 1.56 in
Size
181.102 x 39.7 mm
Special Features
Time-delay Current-limiting AC & DC rated Optional solid state SmartSpot blown fuse indicator Time-delay for motor start-ups and transformer inrush currents without nuisance opening Current-limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick brand recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and high current limitation
Standard
UL listed to standard 248-12 File E2137 CSA certified to standard C22.2 no. 248.12 DC listed to UL standard 248 TRS only
Sub Brand
Tri-Onic®
Type
Class RK5
Voltage Rating
250 VAC
Package Dimensions (L x W x H)
7.13 in x 1.56 in x 1.56 in
Package Dimensions (L x W x H)
181.102 mm x 39.7 mm x 39.7 mm
Package Weight (Imperial)
0.752 lb
Package Weight (Metric)
0.341 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in

Frequently Asked Questions

What are the voltage ratings for TR-R fuses?

TR-R fuses are rated for 250VAC and 250VDC for .1-2.8A and 35-400A. They are also rated for 160VDC for 3-30A and 450-600A.

What is the amperage range for TR-R and TRS-R fuses?

Both TR-R and TRS-R fuses are available in amperage ratings from 1/10 to 600A.

What are the AC and DC interrupting ratings for TR-R fuses?

TR-R fuses have an AC interrupting rating of 200kA and a DC interrupting rating of 20kA.

What are the AC and DC interrupting ratings for TRS-R fuses?

TRS-R fuses have an AC interrupting rating of 200kA. For DC, they are rated 20kA for 1/10-60A and 100kA for 70-600A.

What applications are Tri-Onic TR and TRS fuses designed for?

These fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeder, and branch circuits.

What is the benefit of the time-delay characteristic?

The time-delay characteristic safely handles harmless starting currents and inrush currents associated with motors and transformers without nuisance opening.

What is the SmartSpot® feature?

SmartSpot® is an optional solid-state blown fuse indicator that provides visual indication when the fuse has blown.

Are TR-R and TRS-R fuses UL listed and CSA certified?

Yes, they are UL listed to standard 248-12 and CSA certified to standard C22.2 no. 248.12. TRS fuses are also DC listed to UL standard 248.

How does the rejection-style design benefit users?

The rejection-style design prevents replacement errors when the fuses are used with recommended fuse blocks.

What material is the body of the fuse made from?

The fuse body is made from fiberglass, which provides dimensional stability in harsh industrial settings.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.