Mersen MPDB69073 Open-Style PDB UL 1953 1000V 270A Tin-plated Aluminum - 350A 3-Pole 1 - 6 openings…
Alternate Item Number: MPDB69073
UPC: 782001453053
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- High current capacity of 350A and 1000V voltage rating for demanding applications.
- Durable tin-plated aluminum construction ensures reliable conductivity and longevity.
- Versatile wire range: 500 kcmil - #4 AWG primary, 2/0 AWG - #14 AWG secondary.
- 3-pole configuration with box-to-box connection for flexible wiring.
- UL and CSA approved, meeting UL508A and NEC® spacing requirements.
Specifications
Amperage Rating | 380 A |
Ampere Rating (AL) | 270 A |
Ampere Rating (CU) | 350 A |
Application | Splicing cables Splitting primary power into secondary circuits Fixed junction tap-off points. |
Brand Name | Mersen |
Connection | Box To Box |
Connector Type (Primary) | Box |
Connector Type (Secondary) | Box |
Material | Tin-plated Aluminum |
Mounting | Direct Screw Mount |
Number Of Terminals | 3-pole |
Size | 5.7 x 7.89 x 3.55 in |
Size | 144.78 x 200.406 x 90.17 mm |
Special Features | Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field without the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block. Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated. Many part numbers are rated to accept DLO-type fine-strand wire, allowing users to connect flexible conductors. Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “See-through,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools. Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A. Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block. |
Standard | UL Listed to subject 1953, File E352417 unless noted otherwise CSA Certified Class 6228 01 |
Type | Open-Style Power Distribution Blocks |
Voltage Rating | 1000 V |
Wire Range (Primary) | 500-#4 |
Wire Range (Secondary) | 2/0-#14 |
Package Dimensions (L x W x H) | 5.7 in x 7.89 in x 3.55 in |
Package Dimensions (L x W x H) | 144.78 mm x 200.406 mm x 90.17 mm |
Package Weight (Imperial) | 5.400 lb |
Package Weight (Metric) | 2.449 kg |

MPDB67403
Open-Style PDB UL 1953 1000V 310A Tin-plated Aluminum - 380A 3-Pole 1 - 1 openings; 500-#4 --- 500-#4 Box to Box
AM-R1-H12
Power Distribution Block (1) 500 MCM-4 AWG Primary (12) 4-14 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.
MPDB68323
Open-Style PDB UL 1953 1000V Tin-plated Copper - 620A 3-Pole 2 - 4 openings; 350-#6 --- 4/0-#10 Box to Box
MPDB69110
Open-Style PDB UL 1953 1000V 620A Tin-plated Aluminum - 760A Adder 2 - 12 openings; 500-#4 --- #4-#14 Box to BoxFrequently Asked Questions
What are the voltage and current ratings for Mersen power distribution blocks?
The blocks are rated for 1000VAC/DC and have ampere ratings from 65A to 2260A, based on NEC table 310.15(B)(16) 75ºC ampacities.
What material are the insulators made of?
The insulators are made of virtually unbreakable, glass-filled polycarbonate with a dielectric strength exceeding 2500V.
Are safety covers available for these power distribution blocks?
Yes, optional, snap-on, hinged safety covers made of polycarbonate are available for dead-front protection and shock resistance.
What is the flammability rating of the insulating material?
The insulating material has a flammability rating of UL94-V0.
What is the mounting method for these power distribution blocks?
The power distribution blocks are designed for direct panel mount.
What types of wire connectors are available for these blocks?
Standard aluminum and copper wire connectors are available. Aluminum connectors accept AL or CU wire, while copper connectors accept CU wire only.
Can these blocks accept DLO-type fine-strand wire?
Yes, many part numbers are rated to accept DLO-type fine-strand wire, allowing for the connection of flexible conductors.
What are the spacing requirements for feeder and branch circuits?
The blocks meet spacing requirements of 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity for feeder and branch circuits.
How are adder poles used with these blocks?
Adder poles are optional and can be stacked in the field without tools to form multi-pole units and customize wire combinations.
What is the SCCR rating for these power distribution blocks?
The Short Circuit Current Rating (SCCR) is 100kA when used with a properly sized fuse.
Frequently Asked Questions about Mersen
What industries and applications are Mersen products used for?
Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.
What are the main product lines offered by Mersen?
Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.
What are the key features of Mersen products?
Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.
What environmental ratings do Mersen products have?
Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.
What accessories are available for Mersen products?
Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.
How are Mersen products typically installed?
Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.
What certifications and standards do Mersen products comply with?
Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.
What technical support does Mersen offer?
Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.