Authorized Mersen Distributor
Mersen MPDB68311 - Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 1-Pole 2 - 4 openings; 500-#4 --- 4/0-#10 Box to Box
More images

Mersen MPDB68311 Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 1-Pole 2 - 4 openings; 500-#4…

Alternate Item Number: MPDB68311

UPC: 782001453244


Documents & Media
Line DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen MPDB68311 is an open-style Power Distribution Block (PDB) designed for robust electrical power management. This unit, part of Mersen's MPDB68 series, is rated for 1000V and a substantial 760A current. Constructed with tin-plated copper for optimal conductivity and durability, it features a 1-pole configuration. The block accommodates primary conductor sizes from 500 kcmil down to #4 AWG, and secondary connections range from 4/0 AWG down to #10 AWG, offering significant flexibility for various wiring needs. Its 'box-to-box' design facilitates efficient and secure connections. Mersen power distribution blocks are engineered to provide a safe and straightforward method for splicing cables, splitting primary power into multiple secondary circuits, and establishing fixed junction tap-off points. All Mersen PDBs, including the MPDB68311, are UL and CSA approved and meet the stringent spacing requirements for feeder and branch circuits as defined by UL508A and the National Electrical Code®. This specific model offers two secondary openings. Mersen's MPDB series is categorized into miniature, intermediate, and large sizes, with the MPDB68 series representing the large format, available in both aluminum and copper options. The MPDB68311, with its tin-plated copper construction, ensures reliable performance in demanding industrial applications.
  • 1000V operating voltage for high-power applications
  • 760A continuous current rating for substantial power handling
  • Tin-plated copper construction for superior conductivity and corrosion resistance
  • Accommodates primary conductors from 500 kcmil to #4 AWG
  • Supports secondary conductors from 4/0 AWG to #10 AWG with 2 openings

Specifications

Amperage Rating
760 A
Ampere Rating (CU)
760 A
Application
Splicing cables Splitting primary power into secondary circuits Fixed junction tap-off points.
Brand Name
Mersen
Connection
Box To Box
Connector Type (Primary)
Box
Connector Type (Secondary)
Box
Material
Tin-plated Copper
Mounting
Direct Screw Mount
Number Of Terminals
1
Size
5.7 x 2.73 x 3.55 in
Size
144.78 x 69.342 x 90.17 mm
Special Features
Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field without the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block. Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated. Many part numbers are rated to accept DLO-type fine-strand wire, allowing users to connect flexible conductors. Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “See-through,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools. Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A. Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block.
Standard
UL Listed to subject 1953, File E352417 unless noted otherwise CSA Certified Class 6228 01
Type
Open-Style Power Distribution Blocks
Voltage Rating
1000 V
Wire Range (Primary)
500-#4
Wire Range (Secondary)
4/0-#10
Package Dimensions (L x W x H)
5.7 in x 2.73 in x 3.55 in
Package Dimensions (L x W x H)
144.78 mm x 69.342 mm x 90.17 mm
Package Weight (Imperial)
3.700 lb
Package Weight (Metric)
1.678 kg
Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 1-Pole 2 - 6 openings; 500-#4 --- 2/0-#14 Box to Box

MPDB68101

Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 1-Pole 2 - 6 openings; 500-#4 --- 2/0-#14 Box to Box
DISTRIBUTION BLOCK UNIPOLAR 125 A IEC AND 115 A UR

54111012

DISTRIBUTION BLOCK UNIPOLAR 125 A IEC AND 115 A UR
Splitter Blocks 400 A

CSBL400

Splitter Blocks 400 A
Incoming terminal Feeder component L3 with 2 Modules 36mm width, 200A, 10 mm2 up to 95 mm2 max. 1 wire. For the SMISSLINE TP 125A and 250A system

ZLS253

Incoming terminal Feeder component L3 with 2 Modules 36mm width, 200A, 10 mm2 up to 95 mm2 max. 1 wire. For the SMISSLINE TP 125A and 250A system
100kA Short Circuit Current Rated Power Distribution Block. 2 x 500 MCM-4 AWG Line, 6 x 2/0-14 AWG Load Power Distribution Blocks are made of Valox Nylon 6/6, Finger Safe Lexan 500R Polycarbonate Panels and Covers, high-conductivity 6061-T6 Electro-Tin Plated aluminum alloy connector. Each block can stand alone or combine with other blocks to form a multi-block set, and are also Din Rail Mountable with built in locking mechanism to lock/release.

NPDB-26-500-1

100kA Short Circuit Current Rated Power Distribution Block. 2 x 500 MCM-4 AWG Line, 6 x 2/0-14 AWG Load Power Distribution Blocks are made of Valox Nylon 6/6, Finger Safe Lexan 500R Polycarbonate Panels and Covers, high-conductivity 6061-T6 Electro-Tin Plated aluminum alloy connector. Each block can stand alone or combine with other blocks to form a multi-block set, and are also Din Rail Mountable with built in locking mechanism to lock/release.
Splitter Trough Block Assembly, 600V 600A 4-600MCM:1/0-250 kcmil, Brushed, Aluminum

ASTB600

Splitter Trough Block Assembly, 600V 600A 4-600MCM:1/0-250 kcmil, Brushed, Aluminum
Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 2-Pole 2 - 4 openings; 500-#4 --- 4/0-#10 Box to Box

MPDB68312

Open-Style PDB UL 1953 1000V Tin-plated Copper - 760A 2-Pole 2 - 4 openings; 500-#4 --- 4/0-#10 Box to Box
Open-Style PDB UL 1953 1000V 250A Tin-plated Aluminum - 310A 1-Pole 1 - 1 openings; 350-#6 --- 3/8-16 x 1 Box to Stud

MPDB67251

Open-Style PDB UL 1953 1000V 250A Tin-plated Aluminum - 310A 1-Pole 1 - 1 openings; 350-#6 --- 3/8-16 x 1 Box to Stud

Frequently Asked Questions

What are the voltage and current ratings for MPDB power distribution blocks?

The MPDB series has a voltage rating of 1000VAC/DC and an ampere rating ranging from 65 to 2260A.

Are there optional accessories available for the MPDB series?

Yes, optional accessories include adder poles for field expansion, end barriers, and hinged safety covers for added protection.

How are adder poles installed on the MPDB units?

Adder poles can be stacked to form multi-pole units in the field without the use of tools.

What types of wire can be used with Mersen power distribution blocks?

Aluminum connectors accept both AL or CU wire, while copper connectors accept CU wire only. Many models accept DLO-type fine-strand wire.

What is the flammability rating of the insulating material?

The insulating material, glass-filled polycarbonate, has a flammability rating of UL94-V0.

Are the double-wide MPDB series blocks UL or CSA certified?

Double-wide MPDB series blocks are generally not UL or CSA certified, but are Mersen self-certified and approved.

What is the dielectric strength of the insulating material?

The glass-filled polycarbonate insulating material has a verified dielectric strength exceeding 2500V.

What are the spacing requirements for feeder and branch circuits?

The blocks meet spacing requirements of 1 inch through air and 2 inches over surface between uninsulated live parts.

What wire gauge range is supported by the miniature aluminum MPDBs?

Miniature aluminum MPDBs support wire ranges from 4-14 AWG and 2/0-14 AWG, depending on the specific model.

What are the ampere ratings for copper wire in intermediate aluminum MPDBs?

Intermediate aluminum MPDBs offer copper wire ratings from 175A to 310A per pole, depending on the model and configuration.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.