Authorized Mersen Distributor
Mersen MPDB66512 - Open-Style PDB UL 1953 1000V Tin-plated Copper - 350A 2-Pole 2 - 6 openings; 2/0-#14 --- #2-#14 Box to Box
More images

Mersen MPDB66512 Open-Style PDB UL 1953 1000V Tin-plated Copper - 350A 2-Pole 2 - 6 openings; 2/0-#14…

Alternate Item Number: MPDB66512

UPC: 782001456818


Documents & Media
Line Drawing3D CAD Model (STEP)Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen MPDB66512 is an open-style power distribution block (PDB) designed for safe and efficient cable splicing, power splitting, and fixed junction tap-off points in industrial electrical systems. Rated for 1000V with a 350A current capacity, this UL 1953 and CSA-approved PDB supports 2-pole configurations with 2 to 6 openings. It accommodates wire sizes from 2/0 to #14 for primary inputs and #2 to #14 for secondary outputs, making it ideal for feeder and branch circuit applications. The tin-plated copper construction ensures reliable conductivity and corrosion resistance, while compliance with UL508A and NEC spacing requirements guarantees safety and code adherence. Part of Mersen’s intermediate PDB series (MPDB66 and MPDB67), this block is available in both aluminum and copper variants for flexibility in design and installation. With up to 30 secondary outputs and options for single or dual conductor primary inputs, the MPDB66512 is a versatile solution for power distribution in industrial, commercial, and utility settings.
  • UL 1953 and CSA approved for safety and compliance
  • Rated for 1000V and 350A current capacity
  • Supports 2-pole configurations with 2 to 6 openings
  • Accommodates wire sizes from 2/0 to #14 (primary) and #2 to #14 (secondary)
  • Tin-plated copper construction for corrosion resistance and conductivity

Specifications

Ampere Rating (CU)
350 A
Application
Splicing cables Splitting primary power into secondary circuits Fixed junction tap-off points.
Brand Name
Mersen
Connection
Box To Box
Connector Type (Primary)
Box
Connector Type (Secondary)
Box
Material
Tin-Plated Copper
Mounting
Direct Screw Mount
Number Of Terminals
2-pole
Size
3.08 x 3.57 x 3.25 in
Size
78.232 x 90.678 x 82.55 mm
Special Features
Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field without the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block. Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated. Many part numbers are rated to accept DLO-type fine-strand wire, allowing users to connect flexible conductors. Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “See-through,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools. Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A. Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block.
Standard
UL Listed to subject 1953, File E352417 unless noted otherwise CSA Certified Class 6228 01
Type
Open-Style Power Distribution Blocks
Voltage Rating
1000 V
Wire Range (Primary)
2/0-#14
Wire Range (Secondary)
#2-#14
Package Dimensions (L x W x H)
3.08 in x 3.57 in x 3.25 in
Package Dimensions (L x W x H)
78.232 mm x 90.678 mm x 82.55 mm
Package Weight (Imperial)
2.300 lb
Package Weight (Metric)
1.043 kg
Open-Style PDB UL 1953 1000V Tin-plated Copper - 310A 2-Pole 1 - 1 openings; 350-#6 --- 350-#6 Box to Box

MPDB66002

Open-Style PDB UL 1953 1000V Tin-plated Copper - 310A 2-Pole 1 - 1 openings; 350-#6 --- 350-#6 Box to Box
Splitter Blocks 400 A

CSBL400

Splitter Blocks 400 A
BLOCK MULTI L 125A 4P

54214012

BLOCK MULTI L 125A 4P
S3-M2 POWER INFEED BLOCK

MS325-BB1

S3-M2 POWER INFEED BLOCK
Power Distribution Block (1) 500 MCM-4 AWG Primary (12) 4-14 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.

AM-R1-H12

Power Distribution Block (1) 500 MCM-4 AWG Primary (12) 4-14 AWG Secondary Power Distribution Blocks are made of high strength, high-conductivity aluminum alloy and are mounted in a high-strength glass-filled polyester base. Each block can stand alone or combine with other blocks to form a multi-block set.
Splitter Box Block Assembly, 125 amps, Brushed, Aluminum

ASBB125

Splitter Box Block Assembly, 125 amps, Brushed, Aluminum
Open-Style PDB UL 1953 1000V Tin-plated Copper - 350A 2-Pole 2 - 12 openings; 2/0-#14 --- #4-#14 Box to Box

MPDB68162

Open-Style PDB UL 1953 1000V Tin-plated Copper - 350A 2-Pole 2 - 12 openings; 2/0-#14 --- #4-#14 Box to Box
Open-Style PDB UL 1953 1000V Tin-plated Copper - 620A 2-Pole 2 - 6 openings; 350-#6 --- 2/0-#14 Box to Box

MPDB68132

Open-Style PDB UL 1953 1000V Tin-plated Copper - 620A 2-Pole 2 - 6 openings; 350-#6 --- 2/0-#14 Box to Box

Frequently Asked Questions

What are the voltage and current ratings for Mersen power distribution blocks?

The blocks are rated for 1000VAC/DC and have ampere ratings from 65 to 2260A, based on NEC table 310.15(B)(16) 75ºC ampacities.

What are the available series for Mersen MPDB power distribution blocks?

The MPDB series is offered in miniature (MPDB62 and MPDB63), intermediate (MPDB66 and MPDB67), and large (MPDB68 and MPDB69) sizes.

What types of wire can be used with Mersen power distribution blocks?

Aluminum connectors accept both AL or CU wire, while copper connectors accept CU wire only. Many blocks accept DLO-type fine-strand wire.

Are Mersen power distribution blocks UL and CSA approved?

Unless noted otherwise, all blocks are UL and CSA approved and meet spacing requirements for feeder and branch circuits.

Can additional poles be added to Mersen power distribution blocks?

Yes, optional adder poles can be field-stacked without tools to form multi-pole units and customize wire combinations.

Are safety covers available for Mersen power distribution blocks?

Yes, optional, snap-on, hinged safety covers made of polycarbonate are available for increased safety and shock resistance.

Are there special double-wide series available?

Yes, double-wide series are available for custom applications requiring large ampacities, though they are Mersen self-certified.

What are the spacing requirements for Mersen power distribution blocks?

The blocks meet feeder and branch circuit requirements with 1 inch through air and 2 inches over surface spacing between live parts.

What material are the insulators made of for these power distribution blocks?

The insulators are made of virtually unbreakable, glass-filled polycarbonate with a dielectric strength exceeding 2500V.

How are Mersen power distribution blocks mounted?

These power distribution blocks are designed for direct panel mounting.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.