Authorized Mersen Distributor
Mersen M30J30S - UL 98 Fusible Switch 600VAC Class J 30A 3-Pole Configuration: Side Operated
More images

Mersen M30J30S UL 98 Fusible Switch 600VAC Class J 30A 3-Pole Configuration: Side Operated

Alternate Item Number: M30J30S


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen M30J30S is a UL 98 fusible disconnect switch designed for 600VAC applications, featuring a 30A rating with Class J fuses. This 3-pole, side-operated unit offers fully rated load-break and load-make capabilities for reliable circuit interruption. Its modular design allows for flexible handle positioning among poles, optimizing installation in confined spaces. The double-break mechanism ensures both fuse clips are isolated from voltage during fuse replacement, enhancing safety. Fuse doors are interlocked to prevent opening when the switch is in the ON position. A dedicated TEST position enables auxiliary contact actuation without main power. Power taps are integrated for direct energization of CPTs or surge devices, eliminating the need for separate terminal blocks. This switch supports short-circuit current ratings up to 200kA when used with Class CC, J, or L fuses. It meets UL 98 and CSA requirements. Manufacturer SKU: M30J30S.
  • UL 98 Fusible Disconnect Switch
  • 600VAC, 30A Rating
  • Class J Fuse Compatibility
  • 3-Pole, Side-Operated Configuration
  • 200kA Short-Circuit Current Rating (SCCR)

Specifications

AC Voltage Rating
600 V
Amperage Rating
30 A
Application
Main disconnects Short circuit protection Electrical isolation Overcurrent protection Safety switch
Brand Name
Mersen
Connection
Box
Connection Type
Screw Terminal / Power Taps
Current Rating
30 A
DC Voltage Rating
250 V
Maximum Operating Temperature
40 C
Maximum Operating Temperature
40 °C
Minimum Operating Temperature
-5 C
Minimum Operating Temperature
-5 °C
Mounting
Base Mounted
Mounting Type
Direct Screw Mount
Mounting Type
Side Operated
Nema Rating
Class J
Number of Poles
3
Poles
3-pole
Series
UL 98
Size
4.45 x 5.18 x 4.11 in
Size
113.03 x 131.572 x 104.394 mm
Special Features
Multiple Configurations Power taps Adjustable shaft depth Fuse monitoring Double break, isolating live and load side of fuse Interlocked fuse doors
Standard
All UL Fusible Disconnect Switches meet UL & CSA requirements UL listed guide WHTY, File E191605 for UL 98 (ratings from 30A to 1200A) IEC 60947-3
Type
UL 98 Fusible
Voltage Rating
600 VAC
Package Dimensions (L x W x H)
4.45 in x 5.18 in x 4.11 in
Package Dimensions (L x W x H)
113.03 mm x 131.572 mm x 104.394 mm
Package Weight (Imperial)
1.540 lb
Package Weight (Metric)
0.699 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
MMS-63H 40A EXP

0706001600

MMS-63H 40A EXP
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

Frequently Asked Questions

What is the maximum operating voltage for these switches?

The maximum operating voltage for these switches is 600VAC and 250VDC.

What are the available ampacity ratings for Mersen fusible disconnect switches?

Available ampacity ratings include 30, 60, 100, 200, 400, 600, 800, and 1200A.

What is the Short-Circuit Current Rating (SCCR) for these switches?

The SCCR is up to 200kA when using Class CC, J, or L fuses.

What fuse types are compatible with these switches?

Compatible fuse types include CC, J, and L fuses, depending on the specific model.

Can the fuse doors be opened when the switch is in the ON position?

No, the fuse doors are interlocked and cannot be opened when the switch is in the 'ON' position.

What is the purpose of the 'Test' position on the switch?

The 'Test' position allows for the actuation of auxiliary contacts without energizing the main power.

What are the temperature derating guidelines for these switches?

Temperature derating varies with ambient temperature; for example, at 60-65°C, the derating is 0.80.

What is the minimum recommended handle length for external front operation?

The minimum recommended handle length is 45 mm for NEMA Type 1, 3R, 12, IP65, and 95 mm for higher ampacity switches.

What is the electrical endurance rating for these switches?

The minimum electrical endurance is 6000 operating cycles for lower ampacity ratings and 1000 or 500 cycles for higher ratings.

What is the mechanical endurance rating for these switches?

Mechanical endurance ranges from 20,000 operations for lower ampacity switches down to 2,000 operations for the highest ampacity switches.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.