Mersen GDL1/10 - 250V Time Delay Glass 1/4" x 1 1/4" 250V Volts 0.1 amps GDL series.
Mersen

GDL1/10

Alternate Item Number: 782001763053

UPC: 782001763053

Contact for Pricing

Minimum Qty: 5

Multiplier: 5

*Contact for lower quantities*

Overview

The **Mersen GDL1/10** is a premium **250V time delay glass fuse** engineered for robust overcurrent protection in demanding industrial environments. Part of Mersen’s trusted **GDL series**, this fuse combines precision engineering with a **0.1A current rating** and a **250V voltage rating**, making it an ideal solution for sensitive electronic circuits, control systems, and power supplies where transient surges must be tolerated without nuisance tripping. With a compact **1/4" x 1 1/4" (6.35mm x 31.75mm) glass body**, the GDL1/10 is designed for space-constrained installations, offering engineers and technicians a reliable, space-saving protection component that meets stringent safety and performance standards. **Key Features and Technical Specifications:** The GDL1/10 time delay fuse is specifically designed to provide **selective coordination** in electrical systems by allowing brief overcurrent conditions—such as startup surges or inrush currents—to pass without interrupting operation. This time-delay characteristic is critical in applications where momentary overloads are normal, such as motor starting circuits, transformers, or inductive loads. The fuse’s **0.1A (100mA) rating** ensures precise protection for low-current control circuits, instrumentation, and sensitive semiconductor devices. Its **250V rating** supports use in both AC and DC applications up to this voltage level, making it versatile across a wide range of industrial, commercial, and instrumentation systems. **Typical Applications Across Industries:** The Mersen GDL1/10 is widely deployed in industries that demand **high-reliability circuit protection** with minimal downtime. Common applications include: - **Industrial Control Panels**: Protecting PLCs, relays, and sensor circuits from overcurrent events. - **Power Supply Units**: Safeguarding transformers, rectifiers, and DC power distribution systems. - **Telecommunications Equipment**: Shielding sensitive telecom hardware from transient faults. - **Automotive and Aerospace Testing**: Used in test benches and calibration equipment where precise current thresholds are required. - **Medical Devices**: Ensuring patient safety in diagnostic and therapeutic equipment by preventing overcurrent conditions. **Why Choose Mersen for Time Delay Fuses?** Mersen, a global leader in electrical protection and thermal management solutions, has built a reputation for delivering **high-integrity components** that meet international safety standards. The GDL series, including the GDL1/10, reflects decades of expertise in fuse technology, offering: - **Consistent Performance**: Tight manufacturing tolerances ensure predictable response times and reliable operation across temperature and voltage variations. - **Durable Construction**: The **glass body** provides excellent arc suppression and visual inspection capability, while the internal element is designed for long service life under cyclic loading. - **Global Compliance**: Mersen fuses are certified to **UL, CSA, and IEC standards**, ensuring compatibility with international electrical codes and regulatory requirements. - **Engineering Support**: Mersen provides technical documentation, application guides, and expert support to help engineers select the right fuse for their specific needs. **Installation and Selection Best Practices:** When integrating the GDL1/10 into your system, consider the following guidelines to maximize performance and safety: - **Mounting**: Install in a fuse holder rated for the fuse’s dimensions (1/4" x 1 1/4") and voltage class. Ensure proper clearance for heat dissipation. - **Current Rating**: Select a fuse with a current rating slightly above the normal operating current of the protected circuit to allow for transient conditions, while still providing adequate protection. - **Voltage Rating**: Always match the fuse’s voltage rating to the system voltage to prevent arc-over or failure under fault conditions. - **Replacement**: Use only **identical replacement fuses** (e.g., Mersen GDL1/10) to maintain system coordination and safety compliance. **Industry Trust and Longevity:** Mersen’s GDL series has been a staple in industrial protection for decades, trusted by engineers in power generation, manufacturing, and automation sectors. The time delay feature is particularly valued in applications where **nuisance fuse blowing** would lead to costly downtime or equipment damage. By choosing the GDL1/10, you’re investing in a component that balances **precision, reliability, and durability**—qualities that are essential in mission-critical systems. For professionals seeking a **high-quality, time-delay glass fuse** that delivers consistent performance in 250V applications, the **Mersen GDL1/10** is a proven solution. Whether you’re designing a new control panel, retrofitting existing equipment, or ensuring compliance with safety standards, this fuse provides the protection and peace of mind you need.
  • 250V voltage rating with 0.1A current rating for precise overcurrent protection
  • Time delay characteristic prevents nuisance tripping during transient surges
  • Compact 1/4" x 1 1/4" glass body for space-constrained installations
  • UL, CSA, and IEC certified for global compliance and safety
  • Ideal for industrial control panels, power supplies, and sensitive electronics

Specifications

Amperage Rating
0.1 A
Application
Electronic circuits
Brand Name
Ferraz Shawmut
Connection
Ferrule
Current Rating
0.1A
Interrupt Rating
0.035 kA
Material
Glass
Mounting
Clip
Series
GDL
Size
1/4" x 1 1/4"
Special Features
Glass Body Time-Delay 1/4" X 1/4"
Standard
UL/CSA Std.248-14 1/16A - 8A, 250VAC UL Listed, CSA Certified 10A - 15A 125VAC UL Listed, CSA Certified 20A - 30A, 32VAC UL Listed to U.S. and Canadian safety standards RoHS Compliant
Type
Electronic Fuses
Voltage Rating
250V VAC
Package Dimensions (L x W x H)
1.25 IN x 0.25 IN x 0.25 IN
Package Dimensions (L x W x H)
3.175 cm x 6.35 mm x 6.35 mm
Package Weight (Imperial)
0.010 L
Package Weight (Metric)
0.005 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Block 1500VAC 1500VDC 400A 1-Pole Stud M8

1SCM8

Fuse Block 1500VAC 1500VDC 400A 1-Pole Stud M8
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.