Overview
- Snap-on dead-front cover for Class J fuses (65-100A, 600VAC)
- Optional orange LED indicator shows open fuse (DFC-3I model)
- UL 94-V2 thermoplastic with <0.6 mA leakage current at 600V
- Reusable design—detach and reattach to replacement fuses
- Includes blank label for circuit identification; cover ends cuttable for custom installations
Specifications
AC Voltage Rating | 600 V |
Amperage Rating | 100 A |
Application | To be placed on the fuse for safety |
Brand Name | Ferraz Shawmut |
Current Rating | 100 A |
DC Voltage Rating | 600 V |
Material | Poly |
Mounting | Snap-on |
Phase | 1 |
Series | DFC |
Size | Class J |
Size | 7.87 x 1.3 x 2.2 in |
Size | 199.898 x 33.02 x 55.88 mm |
Special Features | Innovative design provides dead-front electrical safety to personnel Optional orange indicator light shows open fuse Many sizes to fit virtually all popular fuses/fuse blocks Reusable with no changes or additional cost Labels provided for write-in identification Thermoplastic flammability rating of UL 94-V2 Low leakage current <0.6 mA at 600V |
Standard | UL Listed (All except midget size) guide JDVS, File E90426 UL Recognized Component (midget) guide JDVS2, File E90426 CSA Certified class 6228, File 70159 |
Type | Dead Front Cover |
Type | Dead-Front Fuse Covers |
Type Of Indicators | LED |
Voltage Rating | 600 VAC |
Package Dimensions (L x W x H) | 7.57 IN x 1.3 IN x 2.2 IN |
Package Dimensions (L x W x H) | 19.2278 cm x 3.302 cm x 5.588 cm |
Package Weight (Imperial) | 0.120 L |
Package Weight (Metric) | 0.054 kg |

LRU-263
Littelfuse® fuse reducers allow smaller size fuses to be installed into existing fuse clips to prevent overfusing.
TI-1500
The Shawmut Trigger Indicator is a field-mountable blown-fuse indicator which is wired parallel with the fuse to be monitored. The striker pin exerts a static force of one pound and be used to actuate a switch. It is available in 130 volt (TI-130), 600 vo 1500 Volts 70A or higher amps.
TI-130
The Shawmut Trigger Indicator is a field-mountable blown-fuse indicator which is wired parallel with the fuse to be monitored. The striker pin exerts a static force of one pound and be used to actuate a switch. It is available in 130 volt (TI-130), 600 vo 130 Volts 70A or higher amps.
TI-600
The Shawmut Trigger Indicator is a field-mountable blown-fuse indicator which is wired parallel with the fuse to be monitored. The striker pin exerts a static force of one pound and be used to actuate a switch. It is available in 130 volt (TI-130), 600 vo 600 Volts 70A or higher amps.
AOS-Q
Add-On-Switches contain one single-pole doublethrow contact rated 4 amperes resistive and 1 ampere inductive at 250V AC maximum. Two versions of the Add-On-Switch are available. Catalog number -Q accommodates quick connectsFrequently Asked Questions
What is the voltage and amperage rating for DFC covers?
Non-indicating DFC covers are rated for 0 to 600VAC/DC and fit fuses rated 0 to 200A. Indicating models are rated for 90 to 600VAC and 115 to 600VDC, fitting fuses rated 0 to 200A.
What types of fuses are compatible with DFC covers?
DFC covers are designed to fit Class G, H, J, K, R, CC, and midget fuses.
Are Mersen DFC fuse covers reusable?
Yes, DFC fuse covers are reusable. Simply detach from the old fuse and re-attach to the new replacement fuse.
How does the open-fuse indication work on DFC covers?
On indicator models, an orange indicator light will illuminate to show that a fuse has opened.
Can DFC fuse cover ends be modified for installation?
Yes, the ends of DFC fuse covers can be easily cut to accommodate existing wiring, safety switches, or special installations.
Are labels provided with the DFC fuse covers?
Yes, a blank label is provided with each DFC cover for writing in circuit or fuse information.
What safety precautions should be taken before installing DFC covers?
To avoid electrical shock, always turn the power OFF before installing, removing, or servicing the DFC fuse covers.
What are the dimensions for DFC-3I fuse cover?
The DFC-3I fuse cover has dimensions of 7.57 inches in length, 1.30 inches in width, and 2.20 inches in depth.
Which fuse classes are compatible with DFC-7 covers?
DFC-7 and DFC-7I covers are compatible with midget, CC, and G class fuses.
What is the maximum amperage rating for DFC-12 covers?
DFC-12 and DFC-12I covers are designed for fuses rated from 110 to 200A.
Frequently Asked Questions about Mersen
What industries and applications are Mersen products used for?
Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.
What are the main product lines offered by Mersen?
Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.
What are the key features of Mersen products?
Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.
What environmental ratings do Mersen products have?
Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.
What accessories are available for Mersen products?
Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.
How are Mersen products typically installed?
Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.
What certifications and standards do Mersen products comply with?
Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.
What technical support does Mersen offer?
Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.