Authorized Mersen Distributor
Mersen A550C18-70 - Medium Voltage Capacitor Fuse 5500VAC 18A Female To Female Tube Visual Indicator Amp-Trap®
More images

Mersen A550C18-70 Medium Voltage Capacitor Fuse 5500VAC 18A Female To Female Tube Visual Indicator Amp-Trap®

Alternate Item Number: A550C18-70

UPC: 782001334178


Documents & Media
Technical DrawingLine DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen A550C18-70 is a medium voltage capacitor fuse designed for reliable protection of capacitor banks. Manufactured by Mersen, this Amp-Trap® series fuse operates at a maximum voltage of 5500VAC and has an ampere rating of 18A. It features a female-to-female tube mounting configuration and includes a visual indicator for blown fuse status. Designed to ANSI C37-41 standards, these fuses provide current-limiting protection, operating silently and without discharge. They are suitable for indoor use in general-purpose enclosures or outdoor use in weatherproof enclosures. Crucially, these are non-disconnecting fuses and require a disconnect switch for safe operation. The A550C18-70 offers both short-circuit and overload protection, specifically intended to prevent capacitor case rupture or dielectric failure. With a high interrupting rating of 65 kA at 5500V RMS Sym, it ensures robust protection. The overall length is 9.75 inches (247.7 mm), with a tube length of 7.12 inches (180.8 mm) and an indicator housing of 1.00 inch (25.4 mm). The body diameter is 2.00 inches (50.8 mm). Mersen's capacitor fuses are engineered for cost and space-saving solutions in capacitor protection applications. SKU: A550C18-70. Country of Origin: US.
  • 5500VAC maximum voltage rating
  • 18A ampere rating
  • Female to female tube mounting
  • Visual blown fuse indicator
  • Current-limiting protection

Specifications

AC Voltage Rating
5500 V
Amperage Rating
18 A
Application
Capacitor Protection Power Factor Correction Equipment Harmonic Filtering Equipment Induction Heating System High Power Drive Welders
Body Material
GMG
Brand Name
Mersen
Connection
Female To Female Tube
Connection Material
Tin-Plated Brass
Interrupt Rating
65 kA
Mounting
Direct Mount
Size
10 x 2;254 x 50.8 in;mm
Special Features
High interrupting capacity Current limitation Blown-fuse indication Direct mount Clip style mount Bus mount Non-venting for silent operation
Standard
ANSI C37-41
Standard
ANSI
Sub Brand
Amp-Trap®
Type
Capacitor Protection Fuses
Type of Indicators
Visual Indicator
Voltage Rating
5500 VAC
Package Dimensions (L x W x H)
10 in x 2 in x 2 in
Package Dimensions (L x W x H)
254 mm x 50.8 mm x 50.8 mm
Package Weight (Imperial)
2.500 lb
Package Weight (Metric)
1.134 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

Frequently Asked Questions

What is the maximum voltage rating for A550C fuses?

The A550C series capacitor fuses have a maximum voltage rating of 5500V AC.

What is the interrupting rating for A550C fuses?

The interrupting rating for A550C fuses is 65 kA at 5500V RMS symmetrical.

What are the available ampere ratings for the A550C series?

The A550C series is available with ampere ratings from 6 A to 75 A.

What are the dimensions of the A550C18-70 fuse?

The A550C18-70 fuse has an overall length of 10.00 inches, a tube length of 7.12 inches, an indicator housing of 1.00 inch, and a body diameter of 2.00 inches.

What is the melting I2t for the A550C18-70 fuse?

The melting I2t for the A550C18-70 fuse is 3 kA2s.

What is the clearing I2t for the A550C18-70 fuse?

The maximum clearing I2t for the A550C18-70 fuse is 15 kA2s.

What types of enclosures are suitable for Mersen capacitor fuses?

Mersen capacitor fuses can be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure.

Are Mersen capacitor fuses disconnecting type?

No, these are non-disconnecting fuses and require the use of a disconnect switch.

What protection do these capacitor fuses provide?

These capacitor fuses provide both short circuit and overload protection.

What is the purpose of these capacitor fuses?

They are intended to protect against capacitor case rupture or dielectric failure within the capacitor.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.