Authorized Mersen Distributor
Mersen A4BQ6000-TA - Fuse A4BQ - Class L - Time-Delay 600VAC 6000A Blade TA Indicator Amp-Trap 2000®
More images

Mersen A4BQ6000-TA Fuse A4BQ - Class L - Time-Delay 600VAC 6000A Blade TA Indicator Amp-Trap 2000®

Alternate Item Number: A4BQ6000-TA

UPC: 782001294182


Documents & Media
Technical DrawingLine DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Mersen Amp-Trap 2000® A4BQ6000-TA is a Class L time-delay fuse for service entrance protection. It provides 20% greater current limitation than other Class L fuses, reducing let-thru current and energy to safeguard downstream components. Features a 4-second time-delay at 500% rated current to handle inrush from motors/transformers. 300kA interrupting rating (UL witnessed). Pure silver links minimize let-thru current and extend fuse life. Rejection-style design prevents incorrect replacements. High-visibility orange label for identification. A4BQ series reduces Arc Flash energy and offers 2-to-1 selectivity. UL 248-10 listed, CSA C22.2 No. 248.10 certified. '-TA' includes mechanical trigger actuator for blown fuse indication. Applications: mains, feeders, large motors, lighting, heating, general loads, circuit breaker back-up. Fiberglass body for dimensional stability; high-grade silica filler for fast arc quenching. Replaces older Class L fuses, reducing inventory. SKU: A4BQ6000-TA. Made in US.
  • 20% more current-limiting than other Class L fuses
  • 4-second time-delay at 500% rated current for inrush loads
  • 300kA interrupting rating (UL witnessed)
  • Recommended for Arc Flash energy reduction
  • Rejection-style design prevents replacement errors

Specifications

AC Voltage Rating
600 V
Amperage Rating
6000 A
Application
Mains Feeders Large motors Lighting, heating & general loads Circuit breaker back-up DC rated: UPS DC links, battery disconnects, other DC applications
Body Material
GMG
Brand Name
Mersen
Class
Class L
Connection
Blade
Connection Material
Silver-Plated Copper
Connection Type
TA Indicator
Current Rating
6000 A
Fuse Class
L
Interrupt Rating
200 kA
Mounting
Bolted
Series
Amp-Trap 2000
Size
Blade
Size
10.75 x 7.12 in
Size
273.05 x 180.975 mm
Special Features
Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40 lower than the next fastest Class L fuse Time-delay for high inrush loads such as motors and transformers, without nuisance opening 300kA interrupting rating - self-certified, UL witnessed tests Most current-limiting for lowest peak let-thru current even at fault currents up to 300kA Recommended for Arc Flash energy reduction Pure silver links ensure lowest let-thru current and longer fuse life Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts” Rejection-style design prevents replacement errors High-visibility orange label gives instant brand recognition Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator
Standard
A4BQ (100-6000) UL listed to standard 248-10 File E2137 DC listed to UL standard 248 (100-2000A) CSA certified to standard C22.2 No. 248.10 (601-6000A) A4BQ (100-6000) - TA UL listed
Sub Brand
Amp-Trap 2000®
Type
Class L
Type Of Indicators
TA Indicator
Voltage Rating
600 VAC
Package Dimensions (L x W x H)
10.75 in x 7.12 in x 7.12 in
Package Dimensions (L x W x H)
273.05 mm x 180.975 mm x 180.975 mm
Package Weight (Imperial)
41.500 lb
Package Weight (Metric)
18.824 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in

Frequently Asked Questions

What makes A4BQ fuses superior to other Class L fuses?

A4BQ fuses are 20% more current limiting and offer lower let-thru energy, providing superior protection for service entrance equipment.

What is the time-delay characteristic of A4BQ fuses?

A4BQ fuses have a built-in 4-second time-delay at 500% of rated current to accommodate inrush currents without nuisance opening.

What is the interrupting rating for A4BQ fuses?

A4BQ fuses have a 300kA interrupting rating, which is self-certified and UL witnessed for 600VAC.

What are the voltage and amperage ratings for A4BQ fuses?

They are rated for 600VAC and 500VDC. Amperage ratings range from 100 to 6000A for AC and 100 to 3000A for DC.

What does the '-TA' suffix indicate on A4BQ catalog numbers?

The '-TA' suffix indicates the optional mechanical trigger actuator (remote blown fuse indicator) is included.

What applications are A4BQ fuses recommended for?

A4BQ fuses are recommended for mains, feeders, large motors, lighting, heating, general loads, circuit breaker back-up, and DC applications like UPS links.

What standards are A4BQ fuses listed or certified to?

They are UL listed to Standard 248-10 and CSA certified to Standard C22.2 No. 248.10. DC ratings are listed to UL Standard 248.

Can a lower ampere rated Class L fuse replace a higher one?

Yes, a Class L fuse of any lower ampere rating can be substituted for a given Class L fuse due to their dimensioning.

What materials are used in A4BQ fuse links and bodies?

Pure silver links are used for low let-thru current and long life, while the fiberglass body provides dimensional stability.

What is the purpose of the rejection-style design?

The rejection-style design prevents replacement errors, ensuring the correct fuse type is used.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.