Authorized Mersen Distributor
Mersen A228482 - DIN NH Standard fuse-link gG Size NH1 690VAC 400VDC 50A live tags Double indicator Body width 30 mm
More images

Mersen A228482 DIN NH Standard fuse-link gG Size NH1 690VAC 400VDC 50A live tags Double indicator Body…

Alternate Item Number: NH1GG69V50


Documents & Media
Specification Sheet

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Mersen A228482 DIN NH1 gG fuse-link provides full-range breaking capacity protection for industrial electrical systems. Rated for 50A continuous current with a 690VAC/400VDC voltage rating, this NH system fuse-link is designed for plug-in installation with blade contacts and live tag connections. The double indicator design enables clear visual status confirmation without power removal. With a 30mm body width, it fits standard NH1 fuse bases and offers reliable protection against overloads and short circuits up to its breaking capacity. The gG classification ensures full-range interruption capability, protecting cables and equipment from electrodynamic stresses during high short-circuit currents. This fuse-link is part of the IEC-compliant NH system, requiring qualified professional installation due to non-interchangeability design considerations. Ideal for industrial motor control centers, distribution panels, and machinery protection where high breaking capacity and clear status indication are critical.
  • Rated 50A continuous current with 690VAC/400VDC voltage rating
  • Full-range breaking capacity gG fuse-link for complete overload protection
  • Plug-in NH1 system with blade contact and live tag connections
  • Double indicator design for clear visual status confirmation
  • 30mm body width fits standard NH fuse bases

Specifications

AC Voltage Rating
690 V
Amperage Rating
50 A
Application
gG: General purpose cable and line protection
Body Material
Ceramic
Brand Name
Mersen
Connection
Plain Blades
Connection Material
Silver-Plated Copper
DC Voltage Rating
400 V
Interrupt Rating
80 kA
Mounting
Clip
Size
5.31 x 1.18 x 2.52 in
Size
135 x 30 x 64 mm
Special Features
Dimensions according to DIN 43 620 parts 1 to 4 Non-isolated gripping lugs Double indicator 0 cadmium
Standard
VDE 0636 Part 201 IEC 60269-1 and -2
Type
IEC NH Fuse-Links
Type Of Indicators
Double indicator
Voltage Rating
690 VAC
Package Dimensions (L x W x H)
5.31 in x 1.18 in x 2.52 in
Package Dimensions (L x W x H)
135 mm x 30 mm x 64 mm
Package Weight (Imperial)
0.595 lb
Package Weight (Metric)
0.270 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

Frequently Asked Questions

What are the voltage ratings for these NH fuse-links?

The rated voltage AC is 690 V and the rated voltage DC ranges from 250 V to 400 V depending on the size.

What is the ampere range for NH fuse-links?

The ampere range for these fuse-links is from 2 A to 500 A.

What is the breaking capacity of these fuse-links?

The rated breaking capacity for AC is 80 kA for all sizes.

What standards do these NH fuse-links comply with?

These fuse-links comply with VDE 0636 Part 201 and IEC 60269-1 and -2 standards.

What are the available sizes for these NH fuse-links?

The available sizes are 000, 00, 0, 1, 2, and 3.

What is the purpose of the 'gG' designation?

The 'gG' designation indicates that these are full range breaking capacity fuse-links used for general purpose cable and line protection.

What materials are the body and contacts made of?

The body material is ceramic, and the contact materials are copper and silver-plated.

What does the double indicator feature signify?

The double indicator provides a visual signal. The red indicator signals conduction, and it is no longer visible after the fuse-link operates.

Are these fuse-links isolated gripping lug types?

No, these fuse-links feature non-isolated gripping lugs.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.