Authorized Mersen Distributor
Mersen 266 - Fuse Reducer 600V Class H, K 60 - 200
More images

Mersen 266 Fuse Reducer 600V Class H, K 60 - 200

Alternate Item Number: 266

UPC: 782001752354


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications. Fuse reducers are sold in pairs unless otherwise noted.
  • 600V voltage rating for reliable high-voltage applications
  • 60A current rating for precise circuit protection
  • Non-rejection reducers support Class H, K, or R fuses in Class H or K clips
  • Rejection-type reducers ensure compatibility with specific fuse classes
  • Optimizes motor protection by aligning fuses with nameplate currents

Specifications

AC Voltage Rating
600 V
Application
Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications.
Application
Start-up or newly expanding manufacturing facilities ramping up production and electrical demand Temporary use of reduced rating fuse
Brand Name
Ferraz Shawmut
Class
H & K
Size
2.65 x 0.19 x 1.13 in
Special Features
Allow a reduced rating fuse to be installed in a larger fuse holder of the same fuse class Wide range of ratings and sizes
Standard
250V and 600V Class H, K, and R - UL Listed Guide No. IZZR, CSA Certified. 600V Class J - UL Listed Guide No. IZZR, CSA Certified 30-600A
Standard
UL Listed Guide No. IZZR CSA Certified
Type
Fuse Reducer
Type
Fuse Reducers
Voltage Rating
600 VAC
Package Dimensions (L x W x H)
2.65 IN x 1.13 IN x 1.13 IN
Package Dimensions (L x W x H)
6.731 cm x 2.8702 cm x 2.8702 cm
Package Weight (Imperial)
0.670 L
Package Weight (Metric)
0.304 kg
Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount

GPM-SRR90

Fuse Block 600VAC 600VDC Class CC 30A 1/4in Quick Connect / Solder 90 angle screw Knob Panel Mount
Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip

30323R

Fuse Block 600VAC 600VDC Class CC 30A 3-Pole Pressure Plate with Reinforced Clip
Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20

C331156

Fuse Holder UltraSafe™ 800VAC 1000VDC UL Fuse size 14x51 1-Pole Visual Indicator Microswitch Pressure Plate IP20
Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20

E1062696

Fuse Holder Modulostar® Size 10x38 IEC 690VAC 690VDC 3-Pole IP20
POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.

LCC5

POWR-JAW clamps improve the contact between fuse and clip. The unnecessary heat from poor contact due to the loss of spring force in the clips can cause nuisance fuse opening and premature aging of surrounding components. High temperature phenolic resin knob designed for the most severe environments 7 sizes to provide effective coverage. Simple design makes installation easy.
9F61 Size B Clips 1.6in

9F61BWW460

9F61 Size B Clips 1.6in

Frequently Asked Questions

What is the purpose of Mersen Fuse Reducers?

Fuse Reducers allow the use of lower rated fuses in existing equipment with higher ampere rated clips, improving circuit protection.

Are Class J Fuse Reducers suitable for bolt-on applications?

No, Class J Fuse Reducers are not intended for bolt-on applications.

Are Mersen Fuse Reducers UL Listed or CSA Certified?

Yes, they are UL Listed under Guide No. IZZR and CSA Certified.

What is the intended duration of use for Fuse Reducers?

Fuse Reducers are intended for temporary use only.

What types of fuses can Non-rejection Reducers accommodate?

Non-rejection Reducers will allow Class H, K, or R fuses to fit into Class H or K clips.

What fuses do Rejection-type Reducers allow?

Rejection-type Reducers allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips.

What is the voltage rating for Mersen Fuse Reducers?

They are rated for 250V and 600V Class H, K, and R fuses, and for 600 Volt Class J fuses.

What is the ampere rating range for these Fuse Reducers?

The ampere rating range for Mersen Fuse Reducers is from 30 to 600A.

What is the tested interrupt current rating?

These Fuse Reducers have been tested to 200,000A.

What is the function of the R266 catalog number?

The R266 allows a 60A fuse to fit into 200A clips for 600V Class R applications.

Frequently Asked Questions about Mersen

What industries and applications are Mersen products used for?

Mersen products are used across diverse industrial sectors including solar power, electric vehicles, buildings/construction, industrial automation, power distribution, HVAC, elevators, telecommunications, and specialty manufacturing. Key application areas include circuit protection, surge protection, battery module protection, electrical safety systems, and power management for residential, commercial, and utility-scale installations.

What are the main product lines offered by Mersen?

Mersen offers five primary electrical power product lines: IEC and UL/CSA Fuses and Fusegear, Surge Protection, Low Voltage Disconnect Switches, Power Distribution Blocks, and Engineered Solutions. Their comprehensive range includes specialized components like high-speed fuses, modular fuse holders, surge arresters, and custom-engineered electrical protection systems for industrial and power management applications.

What are the key features of Mersen products?

Mersen products feature advanced electrical protection and power management solutions with key characteristics including finger-safe design, compact modularity, and high-performance safety features. Their product lines span electrical power components like fuses, surge protection, power distribution blocks, and specialized solutions for industrial, solar, and building applications. Critical features include UL/CSA approvals, high short-circuit current ratings, and innovative technologies like the Fuse Control™ program that minimize electrical risks and optimize system performance.

What environmental ratings do Mersen products have?

Mersen products meet rigorous environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13, CSA Type 1, 2, 3, 4, 4X, 12, and 13, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They feature IEC 60529 IP66 protection, with enhanced UV inhibitors for outdoor weathering and operating temperatures ranging from -40°C to 130°C (-40°F to 266°F). These ratings ensure superior protection in wet, corrosive, and challenging industrial environments.

What accessories are available for Mersen products?

Mersen offers multiple accessories for their fuse blocks and systems, including safety pullers (DFC3M and DFC3LP), DIN-rail adapters (DRM), bus bars, auxiliary contacts, and specialized mounting hardware. Key accessories include the DFC3M safety puller for 1-1/2" x 13/32" midget or Class CC fuses, the DRM adapter for mounting 303 series fuse blocks on DIN-rail, and UltraSafe fuse module accessories like bus bars and auxiliary contacts that enable module interconnection and monitoring.

How are Mersen products typically installed?

Mersen products are typically installed in electrical distribution systems, control panels, and industrial automation environments using multiple mounting options. These include service entrance panel mounting, distribution panel installation, control panel DIN rail mounting, and custom engineered solutions like Fused Coordination Panelboards. Installation depends on the specific product type, such as fuses, surge protective devices, or switches, and is designed to provide electrical protection and circuit safety in various industrial and commercial applications.

What certifications and standards do Mersen products comply with?

Mersen products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Our products meet rigorous safety and performance standards for industrial applications across North America, China, Russia, and other global markets, ensuring compliance and reliability in electrical power and advanced materials solutions.

What technical support does Mersen offer?

Mersen provides comprehensive technical support through multiple channels, including technical experts located in your time zone who can assist with product selection, application guidance, and troubleshooting. Their Fuse Control™ program offers a free Fuse Inventory Audit & Analysis, and customers can access technical resources through their sales representatives and online platform ep.mersen.com.