Contact for Pricing
Overview
- 400A Current Rating
- 347/600VAC Voltage Rating
- 3-Pole, Neutral, Ground (3P+N+G) Configuration
- IP66/IP67 Dust and Water Ingress Protection
- Durable Metal Gray Housing, Size C

ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the maximum operating voltage?
The maximum operating voltage is 600 VAC and 250 VDC.
What is the temperature range for operation?
The operating temperature range is from -40°F to 140°F.
What is the amperage rating of the device?
The device has an amperage rating ranging from 300 to 600 A.
What are the environmental ratings of the product?
The product has IP66/IP67 environmental ratings.
Can the device be disconnected under load?
No, the device is not intended for connection or disconnection under load.
What type of locking system does it use?
It features a mechanical locking system for safety and watertightness.
Is the device suitable for harsh environments?
Yes, it is designed to be durable in harsh environments.
What safety features are included?
It includes a safety shutter to protect contacts and inhibit access to live parts.
What certifications does the product have?
The product is certified under UL 1682, CSA C22.2 No. 182.1, and NOM.
How to Install the PF and PFQ Series Plugs and Receptacles
This guide provides step-by-step instructions for safely installing and wiring PF and PFQ series plugs and receptacles in high amperage applications.
Estimated time: 1h
Tools needed:
7/8" (22mm) wrench, 5/16" (8mm) Allen wrench, 10mm wrench, Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Heat shrink tubing
- Disconnect Power
Before starting the installation, ensure that all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.
- Mount the Device
Secure the PF or PFQ device to the mounting surface using the provided mounting screws. Ensure that the locking cam is easily accessible and the device is level.
- Wire the Device
Connect the conductors to the terminals as per the wiring instructions. Use straight or 90° compression lugs as required, ensuring that the neutral and ground wires are positioned above the phase wires. Apply heat shrink tubing over the lugs and terminals after wiring.
- Tighten Connections
Bolt the lugs onto the terminals using the supplied M14 screws and washers. Hold the contact bodies with a suitable wrench to prevent transmitting torque to the molding while tightening.
- Install Auxiliary Contacts
Wire the auxiliary contacts according to the provided schematic. Strip the conductors by 0.5 inches (12 mm) and insert them into the respective terminals, tightening the screws until hand tight.
- Calibrate and Test
After installation, verify all connections with a multimeter to ensure proper continuity. Test the device by reconnecting power and checking for correct operation.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.