- 700 Amp current rating for high-power DC applications
- 1500 VDC voltage rating with 60 Hz frequency support
- IP66/IP67 environmental protection for dust and water resistance
- Supports cable diameters from 1.000 to 1.125 inches
- 2 auxiliary contacts for enhanced connectivity
- Size S polyamide construction in black for durability
- Manufactured in the US for consistent quality

1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
MPET4-10R
Modular Emergency Stop - Twist release - Mushroom 40mm - Red - Non-illuminated - - No contact block
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What are the maximum amperage and voltage ratings?
Under CSA ratings, the maximum amperage is 600 A and maximum voltage is 600 VAC. For IEC listings, it can go up to 800 A and 1000 VAC/1500 VDC.
What is the operating temperature range for this product?
The product is designed to operate within a temperature range of -15°F minimum to 140°F maximum.
What environmental protection does the device offer?
When mated, the device provides IP66/IP67 environmental protection. This rating is consistent across CSA, IEC, and NOM listings.
Can this device be connected or disconnected under load?
No, a mechanical interlock prevents connection or disconnection under load. The integral pilot circuit switch controls the power circuit for safety.
What is the wiring capacity for this product?
The wiring capacity ranges from a minimum of 2/0 AWG to a maximum of 777 MCM.
What material are the contacts made from?
The contacts are made of silver, butt-style contact technology. This material maximizes performance, durability, and withstands at least 2000 operations.
Is this device suitable for current interrupting?
No, the device is explicitly rated as "Not for Current Interrupting" under its CSA Ratings.
What are the horsepower ratings for this product?
The horsepower rating is 500 hp for 3Ø applications. This rating applies when auxiliary pilots are wired to control the motor control circuit.
What standards does this product comply with?
The product complies with CSA C22.2 NO. 182.1 and NOM standards. The CSA listing applies to AC devices only.
What are the specifications for the pilot wiring?
The pilot wiring is prewired with a rating of 1A, 240 VAC, and uses 14 AWG wire.
How to Install the 454100P5C SP Series Plug and Receptacle
Installation guide for mounting and wiring the 454100P5C SP series plug and receptacle. Ensure safe and proper installation by following these steps.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter, 3/4" (19 mm) wrench, 24 mm wrench, Crimping tool (Greenlee EK61DL11 or DeWalt 20V MAX with DCE300M2 die)
Supplies needed:
Mounting screws, Terminal connectors, Sealer tape (recommended for threaded connections), Lock washer and nut (for custom installations), Stickers for current and voltage markings
- Verify Power and Ratings
Before installation, disconnect all sources of power to the circuit to eliminate the risk of electrical shock. Verify that the product ratings are appropriate for the application and ensure conductors meet code requirements and are within the wiring terminal capacities noted in Table 3. The ground conductor for CS1000 series devices shall be limited to a maximum size of 1/0 AWG. Conductors should be rated to 90°C or higher. Auxiliary contacts work with 12-14 AWG.
- Prepare Conductors
Select a flexible cable between 2/0 and 777 MCM. Refer to Table 3 for appropriate lug types and strip lengths. If using crimped lugs, ensure they are secured with M12 bolts tightened to approximately 30 ft-lb (40 N.m.). If using threaded lugs, tighten them until the tapered section is securely in solid contact with the terminal. For crimped lugs, apply one crimp with a Greenlee EK61DL11 tool or two crimps with a DeWalt 12-ton tool. Do not crimp past the line on threaded lugs. Use a 24 mm wrench to hold the terminal in place to avoid transmitting torque to the device moldings.
- Wire the Main Conductor
Connect the main conductor to the appropriate terminal. For safety, MELTRIC recommends the following connection sequence: Ground, Neutral, Phase 1, Phase 2, Phase 3.
- Wire the Pilot Contacts
Wire the SP auxiliary/pilot contact leads in series within the power control circuit as shown in the typical pilot circuit wiring diagram.
- Mount the Receptacle or Inlet
If mounting to a panel or accessory, ensure the flat black gasket is installed between the inlet or receptacle and the mounting surface. For custom installations, use watertight seals under the heads of the four mounting bolts and retain with a lock washer and nut. Alternatively, drill and thread four blind holes for #8-32 x 5/8" mounting screws, ensuring sufficient depth for gasket compression. If attaching to the side of an enclosure, position the isolating ring as indicated in Figure 1. Attach the metal angle (if required) to the receptacle or inlet using the supplied screws and gasket, and connect the metal angle to ground. Apply a torque of 17 in-lbs (2 N.m.) to each screw.
- Attach the Handle (if applicable)
Insert the cable through the cable gland and handle before tightening the phase conductor. Assemble the handle with the screws and gasket supplied (use short screws for inlets, long screws for receptacles) and tighten the cable gland with an appropriate tool. MELTRIC threaded lugs are required for use with handles.
- Assemble the Plug/Inlet Cap
Attach the cap to the plug/inlet by retaining the end of the chain under one of the mounting screws.
- Apply Markings
Apply the supplied stickers to indicate the current and voltage of the main circuit on or adjacent to the product so they can easily be seen.
- Verify Watertightness
To achieve rated IP66/IP67 watertightness, ensure the plug and receptacle are mated. When disconnected, the receptacle cap must be fully inserted with the slot aligned with the protruding button, and the plug cap must be pressed firmly into place. Use sealer tape on threaded connections on plug handles or at the junction box if necessary.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.