Contact for Pricing
Overview
- Rated for 600 Amps and 600 Volts AC at 60 Hz
- IP66/IP67 protection against dust and water ingress
- Size S, black poly construction for durability
- Suitable for heavy-duty industrial power distribution
- Manufactured in the US for reliable performance

1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the maximum amperage rating?
The maximum amperage rating is 600 A for CSA and NOM, and 800 A for IEC.
What is the maximum voltage rating?
The maximum voltage rating is 600 VAC for CSA and NOM, and 1000 VAC/1500 VDC for IEC.
What is the operating temperature range?
The operating temperature range is a minimum of -15°F and a maximum of 140°F.
What environmental protection does the device offer?
The device provides IP66/IP67 environmental protection when mated.
Can this device be connected or disconnected under load?
No, a mechanical interlock prevents connection or disconnection under load to ensure safety.
What is the purpose of the pilot circuit?
The integral pilot circuit controls the power circuit, preventing connection and disconnection under load for safety.
What is the wiring capacity for this device?
The wiring capacity ranges from a minimum of 2/0 to a maximum of 777 MCM.
Is this device suitable for current interruption?
No, the device is explicitly stated as "Not for Current Interrupting."
What standards does this product comply with?
The product complies with CSA C22.2 NO. 182.1 and NOM standards. Listing applies to AC devices only.
What is the pilot wiring specification?
The pilot wiring is 1A, 240 VAC, 14 AWG and comes prewired.
How to Install the 44-4800T-P80 Controller
This guide provides step-by-step instructions for the installation and initial setup of the 44-4800T-P80 controller, ensuring safe and effective operation.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter, Torque wrench
Supplies needed:
Mounting screws, Terminal connectors, Gasket, Sealer tape
- Disconnect Power
Before starting the installation, ensure that all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.
- Mount the Controller
Secure the 44-4800T-P80 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect Wiring
Use a flexible cable rated between 2/0 and 777 MCM. Connect the main conductors to the appropriate terminals, ensuring that the threaded lugs are tightened to a torque of 30 ft-lbs (40 N.m) using a 3/4" (19 mm) wrench.
- Wire the Pilot Contacts
Wire the auxiliary/pilot contact leads in series within the power control circuit as per the provided wiring diagram.
- Verify Connections
Use a multimeter to verify that all connections are secure and that there is continuity in the ground circuit.
- Calibrate the Controller
Follow the manufacturer's instructions to perform any necessary calibration of the controller settings to ensure optimal performance.
- Test the Installation
Reconnect power and test the controller to ensure it operates correctly. Monitor for any irregularities during the initial operation.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.