Overview
- Size 2 metal receptacle for industrial applications
- 3-pole plus ground (3P+G) configuration
- 20A current rating at 480VAC, 60Hz
- IP66/67 protection against dust and water jets
- Durable black metal housing for harsh environments
Specifications
Color | Black |
Current Rating | 20 A |
Frequency | 60 Hz |
Ip Rating | IP66/IP67 |
Material | Metal |
Poles | 3P+G |
Series | DXA1 |
Size | Size 2 |
Voltage Rating | 480 VAC |

ACS800-U31-0050-5+E202+K458
WALL-MOUNTED DRIVE ULTRA LOW HARMONIC , Product Family: ACS800, Horsepower: 50 HP, Output Current: 67 A, Voltage: 480 VAC, Voltage Range: 380-500V, NEMA 1 / UL Type 1 (IP21), Wall-mounted, Local or Remote Mounted LCD Display and Keypad, ModBus Adapter, EMC/RFI Filter (1st Envir), 3-Phase Input, 3-Phase Output, Frame: R5, Product HxWxD: 32.12 in x 10.43 in x 15.35 in, Product Weight: 144 lbs
XT6NU3600BFF000XXX
C.BREAKER TMAX T6N 800 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 600 I3=3000...6000 A A FULLY RATED NEUTRAL
1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
MPET4-10R
Modular Emergency Stop - Twist release - Mushroom 40mm - Red - Non-illuminated - - No contact block
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the voltage and polarity for product 28-14043?
Product 28-14043 is rated for 480 V with a 3P+G polarity.
Are hazardous location devices returnable?
No, devices rated for hazardous locations are explicitly stated as not returnable.
What are the main certifications for DXA1?
The DXA1 product line holds CSA and ATEX hazardous location listings, including cCSAus 00.114406X.
What is the maximum voltage and amperage rating?
The DXA1 is rated for a maximum of 20 A and 600 VAC at 60 Hz.
What is the environmental protection rating?
The DXA1 has an IP66/IP67 watertightness rating, achieved when the plug is latched to the receptacle.
What wire sizes are compatible with DXA1?
The DXA1 is compatible with THHN wire sizes ranging from a minimum of 16 AWG to a maximum of 10 AWG.
What is the short circuit rating?
The DXA1 has a short circuit rating of 25 kA Close & Withstand. Testing was performed with a 30 A RK1 fuse.
Does the DXA1 have a locking feature?
Yes, the DXA1 features a locking provision for inserting a locking pin or padlock to prevent inadvertent disconnection.
What material are the contacts made from?
The DXA1 uses silver-nickel contact material, providing superior conductivity, durability, and corrosion resistance.
What is the casing material of the DXA1?
The DXA1 features a robust aluminum metal casing, providing excellent durability and protection in harsh environments.
How to Install the DXA Controller
This guide provides step-by-step instructions for installing and wiring the DXA Controller in industrial applications, ensuring safety and compliance with regulations.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Color-coded gaskets
- Mount the controller
Install the receptacle at a downward angle with the latching pawls at the top and bottom. Ensure it is securely fastened to the panel or DIN rail.
- Prepare the wiring
Remove the appropriate length of cable outer sheath and strip the conductor insulation to the length indicated in Table T2. Ensure the cable sheathing extends through the cord grip for proper sealing.
- Connect the conductors
Insert the stripped conductors into the terminal blocks without fully removing the terminal screws. Tighten the screws to the specified torque in Table T2 to secure the connections.
- Establish grounding connections
Connect all metal parts to the ground terminals provided. Ensure that the factory-wired ground connection is intact and that additional ground conductors are securely attached.
- Insert color-coded gaskets
Place the color-coded gaskets between the device and its rear accessory to maintain the IP rating. Position the protrusions on the gasket correctly according to the installation instructions.
- Test the installation
Use a multimeter to verify the continuity of the ground circuit and check all connections for proper voltage and current ratings. Ensure that all safety shutters are functioning correctly.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.