Overview
- Meltric DXA1 Metal Plug
- 2-Pole plus Ground (2P+G) Configuration
- 20A Current Rating
- 600VAC Voltage Rating
- IP66/67 Ingress Protection
Specifications
Connection Type | 1/2" NPT |
Connection Type | NPT threaded connection |
Current Rating | 20 A |
Ip Rating | IP66/IP67 |
Material | Metal |
Mounting Type | Threaded |
Mounting Type | Conduit Entry |
Poles | 2P+G |
Series | DXA1 |
Voltage Rating | 600 VAC |

1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the maximum voltage and amperage rating?
The maximum amperage for this device is 20 A, and it can operate up to 600 VAC at 60 Hz.
What are the horsepower ratings for this product?
For 1-phase, the ratings are 0.75 hp and 2 hp. For 3-phase, the ratings are 3 hp and 10 hp.
What is the short circuit rating of the device?
The device has a short circuit rating of 25 kA Close & Withstand. Testing was performed with an RK1 30 A fuse.
What is the operating temperature range for the device?
The operating temperature range is a minimum of -67°F and a maximum of 140°F.
What are the hazardous location ambient temperature ratings?
The hazardous location ambient temperature ratings are -55°C to 40°C for T6 and -55°C to 60°C for T5.
What is the maximum wiring capacity for the device?
The wiring capacity, based on THHN wire sizes, ranges from a minimum of 16 AWG to a maximum of 10 AWG.
What hazardous location certifications does the product have?
It has CSA and ATEX hazardous listings, including Ex de IIC T*Gb and Class I Zone I AEx de IIC T*Gb.
What environmental protection rating does the product have?
The product has an IP66/IP67 watertightness rating, which is achieved once the plug is latched to the receptacle.
Are hazardous location devices returnable?
No, devices rated for hazardous locations are explicitly stated as not returnable.
What type of contacts does the product use?
The product uses spring-loaded, butt-style contacts made of silver-nickel, providing superior conductivity and durability.
How to Install the DXA Controller
This guide provides step-by-step instructions for the installation and initial setup of the DXA Controller in industrial environments.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Color-coded gaskets
- Mount the controller
Secure the DXA Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Prepare the wiring
Remove the outer sheath of the cable to the appropriate length and strip the conductor insulation as indicated in the specifications. Ensure that the cable sheathing extends through the cord grip.
- Connect the ground
Connect all metal parts to the ground terminals provided on the DXA Controller. Ensure that the ground connection is secure and that the factory-wired ground is not removed.
- Wire the terminals
Insert the stripped conductors into the contact terminals without fully removing the terminal screws. Tighten the screws to the specified torque to secure the connections.
- Install color-coded gaskets
Insert the color-coded gaskets between the device and its rear accessory to maintain the IP rating. Ensure the protrusions on the gasket are positioned correctly.
- Verify connections
Use a multimeter to verify all electrical connections and ensure there are no short circuits. Check the continuity of the ground circuit.
- Calibrate the device
Follow the manufacturer's instructions to perform any necessary calibration of the DXA Controller after installation.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.