Contact for Pricing
Overview
- 60A current rating for heavy-duty industrial use
- 480 VAC voltage rating with 60 Hz compatibility
- IP66/IP67 ingress protection for harsh environments
- 3P+N+G configuration for balanced three-phase power
- Padlock pawl self-returning lid for secure access control

1SNK705010R0000
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
ACS380-040S-07A2-4
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
XT2NU3090BFF000XXX
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
NNC75X75WH2
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.Frequently Asked Questions
What is the maximum amperage and voltage?
The maximum amperage is 60 A and the maximum voltage is 600 VAC at 60 Hz.
What is the short circuit rating of the device?
The short circuit rating for the device is 25 kA Close & Withstand.
What are the environmental protection ratings?
The environmental protection ratings are IP66/IP67.
What is the wiring capacity for the device?
The wiring capacity is a minimum of 10 AWG and a maximum of 4 AWG. Auxiliary contacts have a maximum capacity of 10 AWG.
What are the cCSAus hazardous location ratings?
The cCSAus hazardous location ratings include Class I Zone 1, Zone 21, Class I Div 2, and Class II Div 2.
What is the cCSAus ambient temperature range?
The cCSAus ambient temperature range is -40°C to +60°C.
What is the ATEX/IECEx maximum amperage and voltage?
For ATEX/IECEx, the maximum amperage is 63 A and the maximum voltage is 750 VAC at 50 Hz.
What are the ATEX/IECEx hazardous location zones?
The ATEX/IECEx hazardous location ratings cover Zones 1 & 2, and Zones 21 & 22.
What is the ATEX/IECEx ambient temperature range?
The ATEX/IECEx ambient temperature range is -40°C to +60°C.
How must receptacles and inlets be mounted?
Receptacles and inlets must be mounted to a DXN handle, angle, or wall box.
How to Install the MELTRIC DXN Series Plugs and Receptacles
This guide provides step-by-step instructions for safely installing and wiring MELTRIC's DXN Series plugs and receptacles in hazardous environments.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Watertight seals
- Disconnect power
Before starting the installation, ensure that all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.
- Mount the receptacle
Secure the DXN receptacle to the wall box or panel using appropriate mounting screws. Ensure that the pawl/latch is oriented at the top for optimal performance.
- Prepare and connect wires
Insert the cable through the wall box, strip the cable sheath, and then strip the individual wires to the lengths specified in Table 3. Twist the strands of each conductor together, back out the terminal screws on the receptacle just enough to insert the conductors, and then tighten the screws to the specified torque.
- Assemble the receptacle
Attach the color-coded gasket and secure the receptacle to the wall box using the provided hardware. Avoid over-tightening to prevent cracking of polymeric components.
- Connect the plug
To connect the plug, align the red arrow on the plug with the red arrow on the receptacle, push the plug in until it hits a stop, rotate it clockwise until it hits another stop, and then push it in fully to secure the connection.
- Verify connections
Use a multimeter to check the electrical continuity of the ground circuit and ensure that all connections are secure and properly tightened.
- Calibrate and test
After installation, test the functionality of the plugs and receptacles by connecting and disconnecting them several times to ensure proper operation.
Frequently Asked Questions about Meltric
What certifications and standards do Meltric products comply with?
Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.
What are the key features of Meltric products?
Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.
What environmental ratings do Meltric products have?
Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).
What industries and applications are Meltric products used for?
Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.
What technical support does Meltric offer?
Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.
What are the main product lines offered by Meltric?
Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.
What accessories are available for Meltric products?
Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.
How are Meltric products typically installed?
Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.
What is Meltric's warranty policy?
Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.