Meltric 22-14073-843 - RECEPTACLE
Meltric

22-14073-843

UPC: 784474665506


Documents & Media
BrochureTechnical DrawingInstallation InstructionsLine Drawing

Contact for Pricing

Overview

The Meltric DXN20 Size 1 Receptacle (SKU: 22-14073-843) is a robust electrical connection solution designed for demanding industrial applications. Constructed from durable black poly material, this receptacle offers exceptional resilience and longevity. It features a 3-pole plus ground configuration (3P+G) and is rated for 20 Amps and 250 Volts AC at a 60 Hz frequency, ensuring reliable power delivery for a variety of equipment. The DXN20 series receptacle boasts an impressive IP66/IP67 rating, providing superior protection against dust ingress and water immersion, making it suitable for harsh environments where moisture and particulate contamination are concerns. Its connection type utilizes a padlock pawl mechanism for secure and tamper-resistant engagement. Manufactured in the USA, this Size 1 receptacle is engineered for straightforward integration into existing electrical systems, offering a dependable interface for machinery and power distribution. The black color provides clear visual identification within control panels and equipment setups. This specific model is ideal for applications requiring a secure, environmentally sealed electrical connection that can withstand rigorous operational conditions.
  • Meltric DXN20 Series, Size 1 Receptacle
  • 20 Ampere, 250 Volt AC, 60 Hz Rating
  • 3-Pole plus Ground (3P+G) Configuration
  • IP66/IP67 Environmental Protection Rating
  • Durable Black Poly Construction with Padlock Pawl
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
General Electric Control Products. Nema Power Devices. Ol Relay 610F8364

CR324E610F

General Electric Control Products. Nema Power Devices. Ol Relay 610F8364
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

Frequently Asked Questions

What is the maximum amperage and voltage for the DXN20?

The DXN20 has a maximum amperage of 20 A. For cCSAus certifications, the maximum voltage is 600 VAC, 60 Hz, and for ATEX/IECEx, it is 550 VAC, 50 Hz.

What are the environmental ratings for the DXN20?

The DXN20 has environmental ratings of IP66/IP67, applicable for both cCSAus and ATEX/IECEx certifications.

What is the operating temperature range for the DXN20?

The ambient operating temperature range for the DXN20 is -40°C to +60°C.

What are the hazardous location ratings for the DXN20?

For cCSAus, it's Class I Zone1 AEx de IIC T5 Gb, Zone 21 AEx tD T90°C Db, Class I Div 2 Gr A,B,C,D, Class II Div 2 Gr E,F,G. For ATEX/IECEx, it's Zones 1 & 2, 21 & 22.

What is the wiring capacity for the DXN20?

The DXN20 supports THHN wire sizes from a minimum of 16 AWG to a maximum of 10 AWG.

What is the short circuit rating of the DXN20?

The short circuit rating is 25 kA Close & Withstand. Testing was performed with an RK1 30 A fuse sized at 400% of the highest full load motor ampacity.

What voltage and polarity is product 22-14073?

Product 22-14073 is rated for 250 V with a 3P+G polarity configuration.

What is the purpose of the -843 suffix on a receptacle?

The -843 suffix indicates a Padlock Pawl option on the receptacle. This option is required for using the LP-843 receptacle locking pin.

Are devices rated for hazardous locations returnable?

No, devices rated for hazardous locations are not returnable. This policy also applies to accessories rated for hazardous locations.

What are the mounting requirements for DXN receptacles and inlets?

Receptacles and inlets must be mounted to a DXN handle, angle, or wall box.

How to Install the MELTRIC DXN Series Plugs and Receptacles

This guide provides step-by-step instructions for safely installing and wiring MELTRIC's DXN Series plugs and receptacles in hazardous environments.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Watertight seals

  1. Disconnect power

    Before starting the installation, ensure that all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.

  2. Mount the receptacle

    Secure the DXN receptacle to the wall box or panel using appropriate mounting screws. Ensure that the pawl/latch is oriented at the top for optimal performance.

  3. Prepare and connect wires

    Insert the cable through the wall box, strip the cable sheath, and then strip the individual wires to the lengths specified in Table 3. Twist the strands of each conductor together, back out the terminal screws on the receptacle just enough to insert the conductors, and then tighten the screws to the specified torque.

  4. Assemble the receptacle

    Attach the color-coded gasket and secure the receptacle to the wall box using the provided hardware. Avoid over-tightening to prevent cracking of polymeric components.

  5. Connect the plug

    To connect the plug, align the red arrow on the plug with the red arrow on the receptacle, push the plug in until it hits a stop, rotate it clockwise until it hits another stop, and then push it in fully to secure the connection.

  6. Verify connections

    Use a multimeter to check the electrical continuity of the ground circuit and ensure that all connections are secure and properly tightened.

  7. Calibrate and test

    After installation, test the functionality of the plugs and receptacles by connecting and disconnecting them several times to ensure proper operation.

Frequently Asked Questions about Meltric

What certifications and standards do Meltric products comply with?

Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.

What are the key features of Meltric products?

Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.

What environmental ratings do Meltric products have?

Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).

What industries and applications are Meltric products used for?

Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.

What technical support does Meltric offer?

Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.

What are the main product lines offered by Meltric?

Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.

What accessories are available for Meltric products?

Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.

How are Meltric products typically installed?

Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.

What is Meltric's warranty policy?

Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.