Overview

The Meltric PN20 Receptacle (SKU: 09-N4073-824-300-LC) is a Size 1 industrial electrical connector designed for harsh environments. This rugged blue metal receptacle delivers reliable 20A power distribution at 250VAC with a 3-pole plus ground (3P+G) configuration. Engineered for IP66/IP67 ingress protection, it resists water, dust, and mechanical impacts in manufacturing, construction, and outdoor installations. The screw-type connection ensures secure electrical contact, while the locking pawl mounting system prevents accidental disconnection under vibration. Compact Size 1 design optimizes space in panel and enclosure applications. Compatible with Meltric’s PN20 series, this receptacle meets stringent industrial standards for durability and electrical safety. Ideal for powering portable tools, temporary lighting, and machinery in demanding settings where consistent connectivity is critical.
  • 20A current rating at 250VAC for reliable power distribution
  • IP66/IP67 ingress protection against water, dust, and impacts
  • 3-pole plus ground (3P+G) configuration for secure electrical connections
  • Screw-type connection with locking pawl mounting for vibration resistance
  • Size 1 compact design for space-constrained industrial applications

Specifications

Color
Blue
Connection Type
Screw Terminal
Current Rating
20 A
Ip Rating
IP66/IP67
Material
Metal
Mounting Type
Locking Pawl Mounting
Poles
3P+G
Series
PN20
Size
Size 1
Voltage Rating
250 VAC
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
MMS-63H 40A EXP

0706001600

MMS-63H 40A EXP
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

Frequently Asked Questions

What are the maximum voltage and amperage ratings?

The device is rated for a maximum of 600 VAC and 20 A. For current interruption, it can handle 20 A up to 480 VAC and 15 A at 600 VAC.

What temperature range can this device operate in?

The device can operate in temperatures ranging from -40°F to 140°F. For temperatures outside this range, refer to page 254 of the documentation.

What environmental ratings does this device have?

The device is rated Type 4X with IP66 and IP67 environmental protection, offering resistance to harsh conditions.

What wire sizes are compatible with this device?

Based on THHN wire sizes, the device supports a minimum of 14 AWG and a maximum of 8 AWG.

What contact material is used in this device?

The device uses silver-nickel contact material, which provides superior conductivity, durability, and corrosion resistance.

How to Install the MELTRIC PN Series Plugs and Receptacles

This guide provides step-by-step instructions for safely installing and wiring MELTRIC PN Series plugs and receptacles, ensuring proper electrical connections and compliance with safety standards.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Allen wrench

Supplies needed:

Mounting screws, Terminal connectors, Fitting seal tape

  1. Disconnect power

    Ensure all sources of power to the circuit are disconnected to eliminate the risk of electrical shock.

  2. Mount the receptacle

    Secure the receptacle to the wall box using appropriate mounting screws. Ensure it is level and firmly attached.

  3. Prepare the wiring

    Insert the cable through the handle and strip the cable jacket to a length of at least 1/2 inch. Strip each conductor according to the lengths specified in Table 3.

  4. Connect the conductors

    Twist the strands of each conductor together and insert them fully into their respective terminals. Tighten the terminal screws to the specified torque in Table 4.

  5. Seal the connections

    Apply fitting seal tape to all NPT fittings to maintain watertightness. Ensure that the handle is securely attached and that the cable jacket extends into the handle.

  6. Verify connections

    Use a multimeter to check for continuity and ensure that all connections are secure and properly grounded.

  7. Test the installation

    Reconnect power to the circuit and test the plug and receptacle by connecting and disconnecting them to ensure proper operation.

Frequently Asked Questions about Meltric

What certifications and standards do Meltric products comply with?

Meltric products are rigorously certified and comply with multiple critical industrial standards, including UL 2682, UL 508, UL 98, UL 1682, and CSA 22.2 No. 182.1. Their devices are UL and CSA listed with comprehensive ratings covering electrical endurance, short circuit withstand capabilities, motor circuit disconnect switching, and environmental protection standards like Type 4X/IP69/IP69K. Specific certifications include switch-rated plug and receptacle listings that exceed standard industry requirements.

What are the key features of Meltric products?

Meltric products feature advanced safety and reliability technologies, including spring-assisted terminals, push-button circuit disconnection, enclosed arc chambers, and integrated lockout-tagout capabilities. Key innovations include silver-nickel butt-style contacts, a quick-break mechanism that disconnects circuits in 15 milliseconds, and a self-cleaning contact system. Most devices offer modular construction, optional auxiliary contacts, and automatic watertightness, with robust casings made of fiberglass-reinforced thermoplastic polyamide that resist impact and harsh environments.

What environmental ratings do Meltric products have?

Meltric products feature robust environmental ratings, including Type 4X/IP69/IP69K certification, which also meets IP66/IP67 requirements. Their devices are rated to operate in temperatures from -40°F to 140°F, with specific IK ratings for impact resistance ranging from 08 to 10 Joules depending on the product material and model. Metal-cased products typically have higher impact resistance (IK10 with 20 Joules) compared to polymer-based products (IK09 with 10 Joules).

What industries and applications are Meltric products used for?

Meltric products are used across multiple heavy industrial and hazardous environments, including chemical plants, pharmaceutical facilities, oil and gas operations, grain silos, wood processing plants, plastics manufacturing, and wastewater treatment facilities. Their specialized plugs and receptacles are engineered for high-amperage equipment, wet/washdown environments, and locations with explosive gas or dust risks, with specific product lines like DSN and DS Series designed for different industrial applications ranging from 75-100 horsepower equipment.

What technical support does Meltric offer?

Meltric offers comprehensive technical support through multiple channels. Their Customer Service group provides immediate phone support at 800-433-7642, with trained representatives located at their manufacturing facility. Additionally, Meltric's engineering team offers specialized application support, custom design solutions, and can help integrate Meltric and third-party components into power distribution products.

What are the main product lines offered by Meltric?

Meltric offers a comprehensive range of industrial electrical plugs and receptacles across several key product lines: Switch-Rated Plugs & Receptacles (DSN and DS series from 20-200A), Multipin Connectors (6-37 pin, 2-50A), Standard Duty Plugs & Receptacles (DR, PN, DSDC series), High Ampacity Plugs & Receptacles (PF/PFQ, DR400, CS1000, SP series from 300-600A), and specialized options like RETTBOX electromagnetic self-ejection devices and PNHT high-temperature connectors.

What accessories are available for Meltric products?

Meltric offers a comprehensive range of accessories for their industrial plugs and receptacles, including handles, angle adapters, junction boxes, poly conduit entry boxes, finger drawplates, and protective/padlockable inlet/plug caps. These modular accessories allow customers to customize their electrical connection solutions, with options like 30° and 70° angles, metal and poly configurations, and additional features such as auxiliary contacts and locking mechanisms.

How are Meltric products typically installed?

Meltric products are typically installed by inserting the plug into the receptacle with a simple 30-degree clockwise rotation, which latches the connection and energizes the circuit. The installation process is designed for safety, featuring automatic watertight sealing, dead-front safety shutters, and spring-loaded butt-style contacts that ensure optimal electrical performance. For motor change-outs, qualified workers follow a specific procedure including verifying de-energization, applying lockout/tagout, and carefully inserting the plug into the receptacle.

What is Meltric's warranty policy?

Meltric offers a comprehensive 5-year warranty on electrical contacts for all its plug and receptacle products. This warranty reflects the company's confidence in the durability and high-quality design of their electrical components, which are engineered to provide superior performance and reliability in industrial applications.