Authorized Littelfuse Distributor
Littelfuse ARP41S - The ARP Series is used in systems where equal run time for two motors is desirable. The selector switch allows selection of alternation of either load for continuous operation. LED’s indicate the status of the output relay. This versatile series may be front panel mounted (BZ1 accessory required) or 35 mm DIN rail mounted with an accessory socket. Operation: Alternating: When the rotary switch is in the “alternate” position, alternating operation of Load A and Load B occurs upon the opening of the control switch S1. To terminate alternating operation and cause only the selected load to operate, rotate the switch to position “A” to lock Load A or position “B” to lock Load B. The LEDs indicate the status of the internal relay and which load is selected to operate. Note: Input voltage must be applied at all times for proper alternation. The use of a solid-state control switch for S1 may not initiate alternation correctly. S1 voltage must be from the same supply as the unit’s input voltage (see connection diagrams on datasheet). Loss of input voltage resets the unit; Load A becomes the lead load for the next operation. Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. The DPDT 8-pin, cross-wired option, allows extra system load capacity through simultaneous operation of both motors when needed. Relay contacts are not isolated.

Littelfuse ARP41S The ARP Series is used in systems where equal run time for two motors is desirable. The…

Alternate Item Number: ARP41S

UPC: 079458991444


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Littelfuse ARP41S (SKU: ARP41S) is an 8-pin SPDT alternating relay for equal run time between two motors. Alternates between Load A and Load B when control switch S1 opens to prevent uneven wear and extend equipment life. Rotary selector switch locks to Load A or B for continuous operation. LED indicators show active load and relay state. Specifications: 10A resistive at 120/240VAC and 28VDC, max 250VAC. Input 120VAC (-20% to +10%), 50/60Hz AC. Mechanical life 10^7 ops, electrical life 10^6 ops. Dimensions 60.7mm (H) x 45.2mm (W) x 81.3mm (D), weight 159g. Mounting: Front panel via BZ1 accessory or 35mm DIN rail with NDS-8 octal socket (10A, 300VAC). NDS-8 secured with #6 screws or DIN rail snaps; PSC8 hold-down clips for vibration resistance. Supports duplexing (cross-wired) for simultaneous Load A and B energization when S1 and S2 closed. Applications: Pump control, HVAC, liquid level management, industrial machinery requiring balanced motor runtime. Input voltage must remain applied for alternation; solid-state control switches require same supply as unit input for proper alternation. Loss of input voltage resets unit, defaulting Load A as lead load. Contacts not isolated.
  • Alternates between two loads (A/B) for equal run time to reduce motor wear
  • SPDT 8-pin electromechanical relay with 10A resistive rating at 120/240VAC
  • Rotary selector switch locks to Load A or B for continuous operation
  • LED indicators show relay status and active load for diagnostics
  • Front panel or 35mm DIN rail mountable with BZ1 or NDS-8 socket accessories
  • Resets to Load A upon input voltage loss
  • Input voltage must remain applied for proper alternation
  • Relay contacts are not isolated

Specifications

Brand Name
Littelfuse
Mounting
Plug-in socket
Mounting
Plug-in socket Mount
Mounting Type
Front panel (with BZ1 accessory) or 35 mm DIN rail
Number Of Poles
Plug-in socket
Operating Temperature
-20 to 60 F
Operating Temperature, Maximum
60 F
Operating Temperature, Minimum
-20 F
Poles
DPDT 8-pin
Series
ARP
Special Features
10Y WARR
Standard
CE/UR/CSA
Sub Brand
SSAC
Package Dimensions (L x W x H)
1.78 IN x 2.39 IN x 3.2 IN
Package Dimensions (L x W x H)
45.2 mm x 60.7 mm x 81.3 mm
The ARP Series is used in systems where equal run time for two motors is desirable. The selector switch allows selection of alternation of either load for continuous operation. LED’s indicate the status of the output relay. This versatile series may be front panel mounted (BZ1 accessory required) or 35 mm DIN rail mounted with an accessory socket. Operation: Alternating: When the rotary switch is in the “alternate” position, alternating operation of Load A and Load B occurs upon the opening of the control switch S1. To terminate alternating operation and cause only the selected load to operate, rotate the switch to position “A” to lock Load A or position “B” to lock Load B. The LEDs indicate the status of the internal relay and which load is selected to operate. Note: Input voltage must be applied at all times for proper alternation. The use of a solid-state control switch for S1 may not initiate alternation correctly. S1 voltage must be from the same supply as the unit’s input voltage (see connection diagrams on datasheet). Loss of input voltage resets the unit; Load A becomes the lead load for the next operation. Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. The DPDT 8-pin, cross-wired option, allows extra system load capacity through simultaneous operation of both motors when needed. Relay contacts are not isolated.

ARP63S

The ARP Series is used in systems where equal run time for two motors is desirable. The selector switch allows selection of alternation of either load for continuous operation. LED’s indicate the status of the output relay. This versatile series may be front panel mounted (BZ1 accessory required) or 35 mm DIN rail mounted with an accessory socket. Operation: Alternating: When the rotary switch is in the “alternate” position, alternating operation of Load A and Load B occurs upon the opening of the control switch S1. To terminate alternating operation and cause only the selected load to operate, rotate the switch to position “A” to lock Load A or position “B” to lock Load B. The LEDs indicate the status of the internal relay and which load is selected to operate. Note: Input voltage must be applied at all times for proper alternation. The use of a solid-state control switch for S1 may not initiate alternation correctly. S1 voltage must be from the same supply as the unit’s input voltage (see connection diagrams on datasheet). Loss of input voltage resets the unit; Load A becomes the lead load for the next operation. Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. The DPDT 8-pin, cross-wired option, allows extra system load capacity through simultaneous operation of both motors when needed. Relay contacts are not isolated.
GSUL2SS Replacement Control Relay

F30674

GSUL2SS Replacement Control Relay
RB121G-12VDC

1SNA645075R0000

RB121G-12VDC
The ECS Series of single-phase AC current sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or undercurrent events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended. Operation: Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition or zero, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.

ECS41BC

The ECS Series of single-phase AC current sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or undercurrent events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended. Operation: Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition or zero, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.
The TCSA Series is a loop-powered, linear output current transducer that provides an output that is directly proportional to the RMS AC current passing through the onboard toroid. The TCSA provides a 4 - 20mA output over a power supply range of 10 - 30VDC. Each unit is factory calibrated for monitoring in one of four ranges; 0-5, 0-10, 0-20, or 0-50A. The 0 - 5A range allows the use of external current transformers so loads up to 1200AC amps can be monitored. See datasheet for operation details.

TCSA20

The TCSA Series is a loop-powered, linear output current transducer that provides an output that is directly proportional to the RMS AC current passing through the onboard toroid. The TCSA provides a 4 - 20mA output over a power supply range of 10 - 30VDC. Each unit is factory calibrated for monitoring in one of four ranges; 0-5, 0-10, 0-20, or 0-50A. The 0 - 5A range allows the use of external current transformers so loads up to 1200AC amps can be monitored. See datasheet for operation details.
The TCSA Series is a loop-powered, linear output current transducer that provides an output that is directly proportional to the RMS AC current passing through the onboard toroid. The TCSA provides a 4 - 20mA output over a power supply range of 10 - 30VDC. Each unit is factory calibrated for monitoring in one of four ranges; 0-5, 0-10, 0-20, or 0-50A. The 0 - 5A range allows the use of external current transformers so loads up to 1200AC amps can be monitored. See datasheet for operation details.

TCSA5

The TCSA Series is a loop-powered, linear output current transducer that provides an output that is directly proportional to the RMS AC current passing through the onboard toroid. The TCSA provides a 4 - 20mA output over a power supply range of 10 - 30VDC. Each unit is factory calibrated for monitoring in one of four ranges; 0-5, 0-10, 0-20, or 0-50A. The 0 - 5A range allows the use of external current transformers so loads up to 1200AC amps can be monitored. See datasheet for operation details.
The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A. Operation: Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS’s toroidal sensor. The trip point range isdivided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS’ toroid and connect the secondary leads together.

TCSH2A

The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A. Operation: Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS’s toroidal sensor. The trip point range isdivided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS’ toroid and connect the secondary leads together.
The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A. Operation: Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS’s toroidal sensor. The trip point range isdivided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS’ toroid and connect the secondary leads together.

TCSG2A

The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A. Operation: Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS’s toroidal sensor. The trip point range isdivided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS’ toroid and connect the secondary leads together.

Frequently Asked Questions

What types of fuses does Littelfuse offer for industrial applications?

Littelfuse offers UL Class fuses, high-speed fuses, medium voltage fuses, 10 x 38 mm fuses, and solar fuses for industrial applications.

What are Littelfuse fuse blocks and holders designed for?

Littelfuse fuse blocks and holders are selected by OEMs and designers for their compact designs, indication features, and DIN-rail mounting flexibility.

What do POWR-BLOKS power distribution blocks provide?

POWR-BLOKS power distribution blocks offer a safe and convenient way to splice cables and manage power distribution requirements within panels and systems.

What is the purpose of Littelfuse feeder protection relays?

Feeder protection relays protect circuits from overcurrent, ground faults, phase loss, overload, and other detrimental conditions.

What is the Industrial Shock-Block® GFCI designed for?

The Industrial Shock-Block® GFCI is designed for people protection in industrial facilities and meets UL Standard 943C Class C and Class D.

How do high-resistance grounding systems benefit industrial applications?

High-resistance grounding limits point-of-fault damage and eliminates arc-flash hazards and transit overvoltages associated with ground faults.

What protection do Littelfuse voltage monitors offer?

Voltage monitors provide protection against both supply line and load side faults when the motor is running.

What functions do Littelfuse timers and flashers control?

Timers and flashers delay starting and stopping loads, and control cycling and sequencing of motors, pumps, compressors, heaters, and lighting.

How do Littelfuse arc-flash protection relays enhance safety?

Arc-flash relays detect a developing arc-flash incident and send a trip signal to interrupt power before significant damage occurs.

What types of motor protection does Littelfuse provide?

Littelfuse offers voltage monitors, current monitors, and Bluetooth enhanced overload relays for low and medium voltage motor protection applications.

Frequently Asked Questions about Littelfuse

What certifications and standards do Littelfuse products comply with?

Littelfuse products are certified to multiple international standards, including UL (Underwriters Laboratories), CSA (Canadian Standards Association), CCC (China Compulsory Certification), and EAC (Eurasian Conformity). Customers can verify specific product certifications by consulting individual product datasheets on Littelfuse.com, which provide comprehensive details about standards compliance for each component.

What industries and applications are Littelfuse products used for?

Littelfuse products are critical for electrical protection and safety across multiple industrial sectors, including manufacturing, automation, power distribution, and electrical control systems. Their comprehensive product portfolio serves industries that require robust electrical protection, including motor and pump applications, solar installations, programmable logic controllers (PLCs), electrical switch panels, and critical infrastructure environments. Key product lines protect against overcurrent, voltage transients, ground faults, and temperature-related electrical risks, ensuring equipment safety and operational reliability.

What technical support does Littelfuse offer?

Littelfuse offers comprehensive technical support through multiple channels. Their Technical Hotline (800-TEC-FUSE) provides direct access to engineers who can help identify issues and recommend solutions. Additionally, Littelfuse offers extensive online Technical Resources at Littelfuse.com, including datasheets, product manuals, whitepapers, application guides, and online design tools. Their experienced product and application engineers also provide step-by-step support from design to installation.

What are the main product lines offered by Littelfuse?

Littelfuse offers comprehensive industrial protection and control product lines, including fuses, fuse holders, protection relays, temperature sensors, and electrical safety components. Their key product categories span surge protective devices, custom OEM products, electrical switch panels, medium voltage fuses, ground-fault protection relays, motor and pump protection devices, and temperature sensors. These products are designed to minimize electrical safety hazards, limit equipment damage, improve productivity, and safeguard personnel from electrical faults.

What are the key features of Littelfuse products?

Littelfuse products feature exceptional circuit protection technologies with key characteristics including UL/IEC safety standard compliance, low internal resistance, and advanced protective capabilities across multiple product lines. Their components provide critical protection for industrial systems, offering features like overcurrent protection, voltage transient suppression, and resettable protection devices with ultra-low resistance and compact designs. Key product lines include fuses, metal oxide varistors (MOVs), TVS diodes, PolySwitch devices, and specialized electronic protection components that enhance system reliability and safety.

What environmental ratings do Littelfuse products have?

Littelfuse products feature comprehensive environmental ratings, including NEMA Type 1, 2, 3, 3R, 4/4X, 12, and 13 certifications, as well as IP65 protection. These ratings ensure superior protection in diverse industrial environments, with an operating temperature range of -40°F to +131°F (-40°C to +55°C). Many products also include UV-stabilized materials and neoprene gaskets for enhanced durability in outdoor and challenging conditions.

What accessories are available for Littelfuse products?

Littelfuse offers several key accessories across their product lines, including fuse holders, voltage monitoring modules, and terminal connectors. Specific accessories include the LPSM003ZXID (indicating) and LPSM003Z (non-indicating) POWR-SAFE Dead Front fuse holders for Class CC and Midget-Style fuses, the VRM6048 voltage monitor accessory module, and female quick connect terminals (P1015 series) in various wire gauge sizes. These accessories are designed to enhance protection, monitoring, and connectivity for Littelfuse electrical components.

What is Littelfuse's warranty policy?

Littelfuse provides comprehensive warranty details on their official website at www.littelfuse.com/warranty. Customers should visit this page to review the specific warranty terms and conditions for their specific product lines. For direct warranty support or questions, customers can contact Littelfuse Technical Support at 1-800-TEC-FUSE or email [email protected].

What communication protocols do Littelfuse products support?

Littelfuse supports a comprehensive range of industrial communication protocols, including PROFIBUS, PROFINET, EtherNet/IP, DeviceNet, Modbus RTU, and CANopen. Our products provide flexible connectivity solutions across multiple industrial automation platforms, enabling seamless integration with various control systems and network architectures.

How are Littelfuse products typically installed?

Littelfuse products are typically installed using specialized mounting hardware like fuse holders, blocks, and panels designed for specific industrial applications. The POWR-SAFE Dead Front holders, for example, provide optimum protection for Class CC and Midget-Style fuses, supporting installations up to 600 VAC/DC. Installation often involves using precision terminals with strain relief, such as 0.25 in. female quick connect terminals, to ensure secure and safe electrical connections in industrial control systems.