Overview

The Kessler Ellis iR Series 4 Channel Temperature Input Module (SKU: iR-AI04-TR) delivers precise, isolated temperature measurements for industrial process control. This 4-channel module supports RTD sensors (Pt100, Pt1000, Ni100) in 2-, 3-, or 4-wire configurations, as well as thermocouples (Types B, E, J, K, L, N, R, S, T, U) with internal or external cold junction compensation. Each channel is electrically isolated for channel-to-channel and input-to-bus isolation, ensuring signal integrity in noisy environments. The module operates on 20–33 VDC with a current consumption of 250 mA at 24 VDC and dissipates 6 W. It features configurable voltage ranges (-10 to +20 mV, -10 to +80 mV, -10 to +460 mV, 0 to +1.0 V, 0 to +6.0 V) and provides a constant 1.0 mA ±1.7% supply to transmitters/sensors. Line break detection is set at 7 kΩ ±10%, and the module operates reliably in ambient temperatures from 0°C to 50°C. Compact dimensions (40.64 mm width × 311.15 mm height × 160 mm depth) allow flexible installation in industrial racks. Ideal for process automation, HVAC systems, and energy management, the iR-AI04-TR ensures accurate, repeatable temperature monitoring with minimal maintenance.
  • 4 isolated temperature input channels for RTDs (Pt100, Pt1000, Ni100) and thermocouples (Types B, E, J, K, L, N, R, S, T, U)
  • Supports 2-, 3-, or 4-wire RTD configurations with internal/external cold junction compensation
  • Galvanic isolation (channel-to-channel and input-to-bus) for noise immunity in industrial environments
  • Operates on 20–33 VDC (250 mA at 24 VDC) with 6 W power dissipation
  • Configurable voltage ranges (-10 to +20 mV, -10 to +80 mV, -10 to +460 mV, 0 to +1.0 V, 0 to +6.0 V)
The Intelligent Rack Security Handle 3-Temperature and Door Sensor connects through the Intelligent Rack Security Handle to the Panduit G5/G6 iPDU or UPS to offer top-, middle- and bottom-of-rack temperature and door status monitoring. The length of the cables from the interface plug to the temperature sensors are 1 at 2 feet (0.6 m), 2 at 6.5 feet (2.3 m) and 10 feet (3.0 m) to the door contact sensor. The temperature sensor measuring range is from 50F - 149F (10C - 65C).

ACF11

The Intelligent Rack Security Handle 3-Temperature and Door Sensor connects through the Intelligent Rack Security Handle to the Panduit G5/G6 iPDU or UPS to offer top-, middle- and bottom-of-rack temperature and door status monitoring. The length of the cables from the interface plug to the temperature sensors are 1 at 2 feet (0.6 m), 2 at 6.5 feet (2.3 m) and 10 feet (3.0 m) to the door contact sensor. The temperature sensor measuring range is from 50F - 149F (10C - 65C).
Temperature sensor PT100 M6 eyelet type

48250209

Temperature sensor PT100 M6 eyelet type
NetBotz Wireless Temp Sensor

NBWS100T

NetBotz Wireless Temp Sensor
HPE G2 PDU Env Temp and Humidi

P9T01A

HPE G2 PDU Env Temp and Humidi
Sensors, ACCPBT Probe NTC IP68 6x20 3m- I/P 10. ACCPBT Probe NTC IP68 6x20 3m- I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10

080G0202

Sensors, ACCPBT Probe NTC IP68 6x20 3m- I/P 10. ACCPBT Probe NTC IP68 6x20 3m- I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10
The Intelligent Rack Security Handle Temperature and Door Sensor connects through the Intelligent Rack Security Handle to the Panduit G5/G6 iPDU or UPS to offer temperature and door status monitoring. The cable length from the interface plug is 1.3 feet (0.4 m) to the temperature sensor and 7.6 feet (2.3 m) to the door sensor. The temperature sensor measuring range is from 50F - 149F (10C - 65C).

ACF10

The Intelligent Rack Security Handle Temperature and Door Sensor connects through the Intelligent Rack Security Handle to the Panduit G5/G6 iPDU or UPS to offer temperature and door status monitoring. The cable length from the interface plug is 1.3 feet (0.4 m) to the temperature sensor and 7.6 feet (2.3 m) to the door sensor. The temperature sensor measuring range is from 50F - 149F (10C - 65C).
Sensors, ACCPBT Probe NTC IP68 6x40 1.5m - I/P 10. ACCPBT Probe NTC IP68 6x40 1.5m - I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10

080G0205

Sensors, ACCPBT Probe NTC IP68 6x40 1.5m - I/P 10. ACCPBT Probe NTC IP68 6x40 1.5m - I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10
Sensors, ACCPBT Probe NTC IP68 6x40 3m - I/P 10. ACCPBT Probe NTC IP68 6x40 3m - I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10

080G0206

Sensors, ACCPBT Probe NTC IP68 6x40 3m - I/P 10. ACCPBT Probe NTC IP68 6x40 3m - I/P 10, Used for product: MCX series, Packing format: Industrial pack, Quantity per packing format: 10