Hammond Power Y015PKCB3L0U - 600V Class Three Phase Autotransformer, 600Y - 480Y Volts, 480Y - 380Y Volts, 15 kVA. Neutral Terminal
Hammond Power

Y015PKCB3L0U

UPC: 803423136505


Documents & Media
BrochureSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Y015PKCB3L0U is a 15 kVA, 3-phase autotransformer designed for applications requiring minor voltage adjustments in distribution systems. As an economical alternative to isolation transformers, it efficiently modifies supply voltage to meet specific load requirements when isolation from the supply line is not a necessity. This unit operates as either a step-up or step-down transformer, offering versatile application possibilities. Key Specifications: - SKU: Y015PKCB3L0U - Manufacturer: Hammond Power - kVA Rating: 15 kVA - Primary Voltage: 600Y Volts - Secondary Voltage: 480Y Volts - Alternate Rating: 480Y Volts to 380Y Volts - Frequency: 60 Hz - Configuration: Three Phase Autotransformer - Neutral Terminal: Included - Insulation System: 130°C (80°C rise) standard - Impedance: Less than 3% - Sound Level: Meets NEMA ST-20 standards - UL Listed: File: E258346 (UL1604, Class I, Division 2) - CSA Certified: File: LR3902 - ABS Type Approval: Certificate No.: 04-HS435190/1-PDA - Country of Origin: US This autotransformer features a heavy-duty Type 3R enclosure for robust protection. Terminations are top accessible with separate high and low voltage lead wires. Standard side and rear knock-outs facilitate installation. The Y015PKCB3L0U is ideal for industrial settings where precise voltage correction is needed without the requirement for galvanic isolation, ensuring optimal performance and longevity of connected equipment. Its compact design and reliable construction make it a practical choice for various voltage adjustment tasks.
  • 15 kVA, 3-Phase Autotransformer for voltage correction
  • Primary: 600Y Volts, Secondary: 480Y Volts (Alternate: 480Y-380Y V)
  • UL Listed (E258346 Class I, Div 2) and CSA Certified (LR3902)
  • Heavy-duty Type 3R enclosure with top accessible terminations
  • Economical solution for voltage adjustment when isolation is not required

Specifications

Application
Economically match system and machine operating voltages where isolation isn't required.
Cooling
Convection cooled
Enclosure
NQT3-N3R - Indoor or Outdoor
Frequency Rating
60 HZ
Height
11.13 in
KVA Rating
15 KVA
Length
5.44 in
Mounting
Floor Mount
Number Of Phases
3
Number Of Taps
ST-20 compliant
Primary Voltage
600Y, 480Y (Alt 480Y, 380Y) V
Secondary Voltage
600Y, 480Y (Alt 480Y, 380Y) V
Special Features
Provides multiple voltages in smaller footprints than isolation transformers.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Type
Autotransformer > Distribution
Width
12.38 in
Package Dimensions (L x W x H)
12.38 IN x 5.44 IN x 11.13 IN
Package Dimensions (L x W x H)
31.4452 cm x 13.8176 cm x 28.2702 cm
Package Weight (Imperial)
61.000 L
Package Weight (Metric)
27.670 kg

Similar Products

Y015CECB3L0U


Primary Voltage: 240Y, 216Y, 208Y V

Secondary Voltage: 240Y, 216Y, 208Y V

Voltage Rating: 600V Class

Y045PKCN3L0U


Enclosure: NH5-N3R - Indoor or Outdoor

Height: 21.5 in

KVA Rating: 45 KVA

Y075PKCN3L0U


Enclosure: NH5-N3R - Indoor or Outdoor

Height: 21.5 in

KVA Rating: 75 KVA

Y003PKCB3L0U


Enclosure: NQT2-N3R - Indoor or Outdoor

Height: 8.63 in

KVA Rating: 3 kVA

Y006PKCB3L0U


Enclosure: NQT2-N3R - Indoor or Outdoor

Height: 8.63 in

KVA Rating: 6 kVA

Y009PKCB3L0U


KVA Rating: 9 kVA

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.