- Rated for 480V, 200A, 60Hz operation
- Designed for MDB/TCP open configurations
- Compliant with IEEE 519 harmonic standards
- Compact design for easy panel integration
Specifications
Ambient Temperature | 0°C to 40°C Deg C |
Application | Chemical Processing, Data Centers, HVAC, Material Handling, Mining, Oil & Gas, Pulp & Paper, Hospitals, Wastewater |
Communication Option | Modbus TCP |
Connection Type | MDB/TCP open |
Current Rating | 200 A |
Enclosure | Open Frame |
Frequency | 60 Hz |
Frequency Rating | 60 HZ |
Height | 54 in |
Ip Rating | MDB/TCP open |
Length | 13.7 in |
Mounting | Wall mount |
Special Features | Active Filter for harmonic mitigation and power factor correction. Options include Ethernet, Ethernet IP, and Modbus communication options. |
Standard | cUL |
Type | Filter > Active Harmonic Filter |
Voltage Rating | 480 VAC |
Width | 22 IN |
Frequently Asked Questions
What is the primary function of the HPS TruWave Active Harmonic Filter?
The AHF is designed to reduce total demand distortion (TDD) and total harmonic distortion (THD(V)) to less than 5%, correct linear displacement, and balance incoming three-phase current.
What are the operating temperature and humidity ranges for the AHF?
The AHF operates in ambient temperatures from 0°C to 40°C and humidity levels from 0 to 95% non-condensing.
What input voltages can the AHF operate with?
The AHF can operate from an input voltage of 480, 240, or 208 VAC, with a tolerance of +12%, -15%.
What is the efficiency rating of the AHF?
The AHF efficiency is no less than 98% at full load, with heat losses not exceeding 2% of the unit's KVAR rating.
How does the AHF handle overload conditions?
The AHF uses electronic current limiting to limit its output to 100% RMS of the system current rating and has redundant overload protection with Class T fuses.
What types of enclosures are available for the AHF?
AHFs rated 50-200 amps are in wall-mountable NEMA Type 1 enclosures, while 300-amp systems are in floor-mountable enclosures.
Can multiple AHF units be used together?
Yes, multiple systems can be paralleled to achieve the required harmonic correction if it exceeds the maximum current rating of a single unit, up to six systems.
What is the purpose of the Standby/Power Saving function?
This function automatically disables the AHF inverter when the load power drops below a user-selected level, saving power or disabling the AHF when an alternate input source is used.
How does the AHF log events and data?
The AHF can record the last 1,856 reset events and 480 shutdown events, including reasons, dates, times, and various system parameters, with battery backup memory.
What information is available on the AHF's LCD touch screen display?
The LCD touch screen displays power quality information (voltage, current, THD, harmonics, KW, KVA, PF), operating status, system temperatures, currents, voltages, and historical data.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.