Overview

The Hammond Power WAHF1K050F-I is an open-style Active Harmonic Filter designed for industrial applications requiring power quality improvement. This unit operates at 480V and has a 50A rating, with a standard operating frequency of 60Hz. It features Ethernet/IP (ETH/IP) communication, enabling seamless integration into modern industrial control systems and providing valuable data for monitoring and diagnostics. Active Harmonic Filters are crucial for mitigating harmonic distortion caused by non-linear loads, such as variable frequency drives (VFDs), LED lighting, and switching power supplies. By actively injecting compensating currents, the WAHF1K050F-I effectively reduces total harmonic distortion (THD) in the electrical system. This leads to improved power factor, reduced energy losses, extended equipment lifespan, and prevention of nuisance tripping of circuit breakers and sensitive electronic equipment. The open-style design allows for flexible integration into existing control panels or custom enclosures, offering a compact and efficient solution for power quality challenges. This filter is an essential component for facilities aiming to comply with power quality standards and optimize electrical system performance. Manufacturer: Hammond Power. SKU: WAHF1K050F-I. UNSPSC Code: 83101808.
  • Active Harmonic Filter for industrial power quality
  • 480V operating voltage
  • 50A current rating
  • 60Hz operating frequency
  • Ethernet/IP (ETH/IP) communication protocol

Specifications

Ambient Temperature
0°C to 40°C Deg C
Application
Chemical Processing, Data Centers, HVAC, Material Handling, Mining, Oil & Gas, Pulp & Paper, Hospitals, Wastewater
Communication Option
Ethernet/IP
Enclosure
Open Frame
Frequency Rating
60 HZ
Height
45 in
Length
12.7 in
Mounting
Wall mount
Special Features
Active Filter for harmonic mitigation and power factor correction. Options include Ethernet, Ethernet IP, and Modbus communication options.
Standard
cUL
Type
Filter > Active Harmonic Filter
Width
16.9 IN
Active Harmonic Filter 480V 50A 60Hz ETH open;used on 600V w/auto

WAHF1K050F-E6P1

Active Harmonic Filter 480V 50A 60Hz ETH open;used on 600V w/auto
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW
Active Harmonic Filter 480V 200A 60Hz ETH open;used on 400V

WAHF1K200F-E6H

Active Harmonic Filter 480V 200A 60Hz ETH open;used on 400V
Active Harmonic Filter 480V 50A 60Hz ETH type 1;used on 600V w/auto

WAHF1K050A-E6P1

Active Harmonic Filter 480V 50A 60Hz ETH type 1;used on 600V w/auto
Active Harmonic Filter 480V 150A 60Hz MDB/TCP open;used on 600V w/auto

WAHF1K150F-T6P1

Active Harmonic Filter 480V 150A 60Hz MDB/TCP open;used on 600V w/auto
Active Harmonic Filter 240V 200A 60Hz MDB/TCP type 1

WAHF1D200A-T

Active Harmonic Filter 240V 200A 60Hz MDB/TCP type 1
Active Harmonic Filter 240V 50A 60Hz MDB/TCP type 1

WAHF1D050A-T

Active Harmonic Filter 240V 50A 60Hz MDB/TCP type 1
Active Harmonic Filter 480V 100A 60Hz ETH type 1;used on 600V w/auto

WAHF1K100A-E6P1

Active Harmonic Filter 480V 100A 60Hz ETH type 1;used on 600V w/auto

Frequently Asked Questions

What is the purpose of the HPS TruWave Active Harmonic Filter?

The AHF is designed to reduce total demand distortion (TDD) and total harmonic distortion (THD(V)) to less than 5%, correct linear displacement, and balance incoming three-phase current.

What information is available on the AHF's LCD touch screen display?

The display shows power quality information (voltage, current, THD, harmonics, power factor), operating status, system temperatures, currents, DC bus voltage, and allows parameter setting and historical data viewing.

What are the operating voltage and frequency ranges for the AHF?

The AHF operates from 480, 240, or 208 VAC (3-phase, 3-wire plus ground) with a tolerance of +12%, -15%. It supports 50 or 60 Hz, ±5 Hz.

How does the AHF record shutdown and reset events?

The AHF can record the last 1,856 reset events and 480 shutdown events, including date/time stamps and fault reasons, with battery backup memory.

Does the AHF support remote monitoring and control?

Yes, it has an Ethernet communications interface for configuration, diagnostics, data collection, and remote enable/disable. It also features three status relays and a remote enable/disable dry contact input.

What are the environmental operating conditions for the AHF?

The AHF operates in ambient temperatures from 0°C to 40°C and humidity from 0 to 95% (non-condensing). It can operate up to 1000 M altitude, with de-rating at higher altitudes.

Can multiple AHF units be installed in parallel?

Yes, multiple systems can be installed in parallel, up to six units, if the harmonic correction needed exceeds the maximum current rating of a single AHF.

What are the requirements for external current transformers (CTs)?

CTs must be split core type, rated for the total rated RMS current, have a 5-ampere output, and be rated for 400 Hz. The AHF has a function to verify correct CT installation.

What is the efficiency of the AHF at full load?

The AHF efficiency is no less than 98% at full load, with heat losses not exceeding 2% of the unit's KVAR rating.

What type of enclosure is the AHF provided in?

AHFs rated for 50-200 amps are in NEMA Type 1 gasketed, wall-mountable enclosures. 300-amp systems are in floor-mountable (freestanding) enclosures.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.